메뉴 건너뛰기




Volumn 4503, Issue , 2001, Pages 230-239

High resolution element mapping inside biological samples using fluorescence microtomography

Author keywords

Compound refractive lenses; Fluorescence analysis; Tomography; X ray microbeam

Indexed keywords

FLUORESCENCE; HEAVY METALS; IONS; LENSES; TISSUE; X RAY ANALYSIS;

EID: 15844426519     PISSN: 0277786X     EISSN: None     Source Type: Journal    
DOI: 10.1117/12.452850     Document Type: Article
Times cited : (21)

References (17)
  • 3
    • 0026370093 scopus 로고
    • Fluorescent computer tomography: A model for correction of x-ray absorption
    • J.P. Hogan, R.A. Gonsalves, and A.S. Krieger, "Fluorescent computer tomography: A model for correction of x-ray absorption," IEEE Trans. Nucl. Sci. 38(6), pp. 1721-1727, 1991.
    • (1991) IEEE Trans. Nucl. Sci. , vol.38 , Issue.6 , pp. 1721-1727
    • Hogan, J.P.1    Gonsalves, R.A.2    Krieger, A.S.3
  • 5
    • 0031996743 scopus 로고    scopus 로고
    • X-ray fluorescent computer tomography with synchrotron radiation
    • G.-F. Rust and J. Weigelt, "X-ray fluorescent computer tomography with synchrotron radiation," IEEE Trans. Nucl. Sci. 45(1), pp. 75-88, 1998.
    • (1998) IEEE Trans. Nucl. Sci. , vol.45 , Issue.1 , pp. 75-88
    • Rust, G.-F.1    Weigelt, J.2
  • 9
    • 0034467753 scopus 로고    scopus 로고
    • Fluorescence microtomography: External mapping of elements inside biological samples
    • Penetrating Radiation Systems and Applications II, F.P. Doty, H.B. Barber, H. Roehrig, and E.J. Morton, eds., SPIE, (Bellingham)
    • C.G. Schroer, J. Tümmler, T.F. Günzler, B. Lengeler, W.H. Schröder, A.J. Kuhn, A.S. Simionovici, A. Snigirev, and I. Snigireva, "Fluorescence microtomography: External mapping of elements inside biological samples," in Penetrating Radiation Systems and Applications II, F.P. Doty, H. B. Barber, H. Roehrig, and E.J. Morton, eds., vol. 4142 of Proceedings of the SPIE, pp. 287-296, SPIE, (Bellingham). 2000.
    • (2000) Proceedings of the SPIE , vol.4142 , pp. 287-296
    • Schroer, C.G.1    Tümmler, J.2    Günzler, T.F.3    Lengeler, B.4    Schröder, W.H.5    Kuhn, A.J.6    Simionovici, A.S.7    Snigirev, A.8    Snigireva, I.9
  • 11
    • 0033334829 scopus 로고    scopus 로고
    • Monte carlo simulation of x-ray fluorescence spectra: Part 4. Photon scattering at high x-ray energies
    • L. Vincze, K. Janssens, B. Vekemans, and F. Adams, "Monte Carlo simulation of x-ray fluorescence spectra: Part 4. photon scattering at high x-ray energies," Spectrochim. Acta, Part B 54, pp. 1711-1722, 1999.
    • (1999) Spectrochim. Acta , vol.54 , pp. 1711-1722
    • Vincze, L.1    Janssens, K.2    Vekemans, B.3    Adams, F.4
  • 12
    • 0032596587 scopus 로고    scopus 로고
    • Monte carlo simulation of x-ray fluorescence and scattering tomography experiments
    • Developments in X-ray Tomography II, U. Bonse, ed. SPIE, (Bellingham)
    • L. Vincze, K. Janssens, B. Vekemans, and F. Adams, "Monte Carlo simulation of x-ray fluorescence and scattering tomography experiments," in Developments in X-ray Tomography II, U. Bonse, ed. vol. 3772 of Proceedings of the SPIE, pp. 328-337, SPIE, (Bellingham), 1999.
    • (1999) Proceedings of the SPIE , vol.3772 , pp. 328-337
    • Vincze, L.1    Janssens, K.2    Vekemans, B.3    Adams, F.4
  • 13
    • 0035903383 scopus 로고    scopus 로고
    • Reconstructing x-ray fluorescence microtomograms
    • To be published
    • C.G. Schroer, "Reconstructing x-ray fluorescence microtomograms," Appl. Phys. Lett., 2001. To be published.
    • (2001) Appl. Phys. Lett.
    • Schroer, C.G.1
  • 17
    • 84967173692 scopus 로고
    • Function minimization by conjugate gradients
    • R. Fletcher and C.M. Reeves, "Function minimization by conjugate gradients," Computer J. 7, pp. 149-154, 1964.
    • (1964) Computer J. , vol.7 , pp. 149-154
    • Fletcher, R.1    Reeves, C.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.