메뉴 건너뛰기




Volumn 5535, Issue , 2004, Pages 182-190

Aspects of X-ray microtomography equipment design

Author keywords

Microtomography; Signal to noise ratio; X ray

Indexed keywords

ATTENUATION; CAMERAS; CHARGE COUPLED DEVICES; FIBER OPTICS; MONOCHROMATORS; PRODUCT DESIGN; SIGNAL TO NOISE RATIO; X RAY APPARATUS;

EID: 15844421583     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.556311     Document Type: Conference Paper
Times cited : (6)

References (5)
  • 1
    • 0028499338 scopus 로고
    • The effect of linear interpolation of the filtered projections on image noise in X-ray computed tomography
    • G.R. Davis, "The effect of linear interpolation of the filtered projections on image noise in X-ray computed tomography," J. X-ray Sci. Tech., 4, pp. 191-199 (1994).
    • (1994) J. X-ray Sci. Tech. , vol.4 , pp. 191-199
    • Davis, G.R.1
  • 2
    • 0001718569 scopus 로고
    • Optimum energies for X-ray transmission tomography of small samples- Applications of synchrotron radiation to computed tomography I
    • L. Grodzins, "Optimum Energies for X-ray Transmission Tomography of Small Samples- Applications of Synchrotron Radiation to computed tomography I," Nucl. Instrum. Meth., 206, pp. 541-546 (1983).
    • (1983) Nucl. Instrum. Meth. , vol.206 , pp. 541-546
    • Grodzins, L.1
  • 3
    • 0031192722 scopus 로고    scopus 로고
    • X-ray microtomography scanner using time-delay integration for elimination of ring artefacts in the reconstructed image
    • G.R. Davis, J.C. Elliott, "X-ray microtomography scanner using time-delay integration for elimination of ring artefacts in the reconstructed image," Nucl. Instr. Meth. Phys. Res. A, 394, pp. 157-162 (1997).
    • (1997) Nucl. Instr. Meth. Phys. Res. A , vol.394 , pp. 157-162
    • Davis, G.R.1    Elliott, J.C.2
  • 4
    • 0038392744 scopus 로고    scopus 로고
    • High definition X-ray microtomography using a conventional impact X-ray source
    • G.R. Davis and J.C. Elliott, High definition X-ray microtomography using a conventional impact X-ray source," J. Phys. IV France, 104, pp. 131 - 134 (2003).
    • (2003) J. Phys. IV France , vol.104 , pp. 131-134
    • Davis, G.R.1    Elliott, J.C.2
  • 5
    • 2542464481 scopus 로고    scopus 로고
    • A model-based correction method for beam hardening artefacts in X-ray microtomography
    • E. Van de Casteele, D. Van Dyck, J. Sijbers and E. Roman, "A model-based correction method for beam hardening artefacts in X-ray microtomography," J. X-ray Sci. Tech., 12, pp. 43-57 (2004).
    • (2004) J. X-ray Sci. Tech. , vol.12 , pp. 43-57
    • Van De Casteele, E.1    Van Dyck, D.2    Sijbers, J.3    Roman, E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.