메뉴 건너뛰기




Volumn 58, Issue 3, 1996, Pages 127-135

Speech understanding in quiet and in noise with the cis speech coding strategy (MED-EL Combi-40) compared to the multipeak and spectral peak strategies (nucleus)

Author keywords

Cochlear implant; Continuous interleaved sampling; Multipeak speech coding; Spectral peak speech coding; Speech coding; Speech understanding

Indexed keywords

ADULT; ARTICLE; CLINICAL ARTICLE; COCHLEA PROSTHESIS; COMPREHENSION; HEARING LOSS; HUMAN; INTERMETHOD COMPARISON; NOISE; PRIORITY JOURNAL; SPEECH DISCRIMINATION;

EID: 15844391441     PISSN: 03011569     EISSN: 14230275     Source Type: Journal    
DOI: 10.1159/000276812     Document Type: Article
Times cited : (54)

References (17)
  • 1
    • 0028827611 scopus 로고
    • Multicentric field evaluation of a new speech coding strategy for cochlear implants
    • Dillier N, Battmer RD, Döring WH, Müller-Deilc J: Multicentric field evaluation of a new speech coding strategy for cochlear implants. Audiologv 1995;34:145-159.
    • (1995) Audiologv , vol.34 , pp. 145-159
    • Dillier, N.1    Battmer, R.D.2    Döring, W.H.3    Müller-Deilc, J.4
  • 2
    • 0027430650 scopus 로고
    • New processing strategies for multichannel cochlear prosthesis
    • Lawson DT, Wilson BS, Finley CC: New processing strategies for multichannel cochlear prosthesis. Prog Brain Res 1993:97:313-321.
    • (1993) Prog Brain Res , vol.97 , pp. 313-321
    • Lawson, D.T.1    Wilson, B.S.2    Finley, C.C.3
  • 4
    • 0027362047 scopus 로고
    • Perceptual performance of subjects with cochlear implants using the Spectral Maxima Sound Processor (SMSP) and the Mini Speech Processor (MSP)
    • McKay CM, McDermott HJ: Perceptual performance of subjects with cochlear implants using the Spectral Maxima Sound Processor (SMSP) and the Mini Speech Processor (MSP). Ear Hear 1993:14:350-367.
    • (1993) Ear Hear , vol.14 , pp. 350-367
    • McKay, C.M.1    McDermott, H.J.2
  • 5
    • 0000234772 scopus 로고
    • Response characteristics of nerve fibers to patterned electrical stimulation
    • Miller JM. Spelman FA (eds), New York, Springer
    • Hartmann R, Klinke R: Response characteristics of nerve fibers to patterned electrical stimulation: in Miller JM. Spelman FA (eds): Cochlear Implants. Models of the electrically Stimulated Ear. New York, Springer. 1989. pp 135-160.
    • (1989) Cochlear Implants. Models of the Electrically Stimulated Ear , pp. 135-160
    • Hartmann, R.1    Klinke, R.2
  • 6
    • 0001929328 scopus 로고
    • Encoding of temporal information
    • Miller JM. Spelman FA (eds), New York. Springer
    • Javcl E: Encoding of temporal information: in Miller JM. Spelman FA (eds): Cochlear Implants, Models of the Electrically Stimulated Ear. New York. Springer. 1989. pp 247-295.
    • (1989) Cochlear Implants, Models of the Electrically Stimulated Ear , pp. 247-295
    • Javcl, E.1
  • 7
    • 0019286073 scopus 로고
    • Speech processing for a multiple-electrode cochlear implant hearing prosthesis
    • Tong YC, Clark GM, Seligman PM, Patrick JF: Speech processing for a multiple-electrode cochlear implant hearing prosthesis. J Acoust SocAm 1980:68:1897-1899.
    • (1980) J Acoust Socam , vol.68 , pp. 1897-1899
    • Tong, Y.C.1    Clark, G.M.2    Seligman, P.M.3    Patrick, J.F.4
  • 9
    • 0023600936 scopus 로고
    • Speech perception using a two formant 22-clectrode cochlear prosthesis in quiet and in noise
    • Dowell RC, Seligman PM, Blarney PJ, Clark GM: Speech perception using a two formant 22-clectrode cochlear prosthesis in quiet and in noise. Acta Otolaryngol (Stockh) 1987:104: 439-446.
    • (1987) Acta Otolaryngol (Stockh) , vol.104 , pp. 439-446
    • Dowell, R.C.1    Seligman, P.M.2    Blarney, P.J.3    Clark, G.M.4
  • 10
    • 0000886707 scopus 로고
    • Preliminary results with a six spectral maxima sound processor for the University of Melbourne/Nucleus multiplc-clcctrodc cochlear implant
    • McKay C, McDermott HJ, Vandali A, Clark GM: Preliminary results with a six spectral maxima sound processor for the University of Melbourne/Nucleus multiplc-clcctrodc cochlear implant. J Otolaryngol Soc Aust 1991:6: 354-359.
    • (1991) J Otolaryngol Soc Aust , vol.6 , pp. 354-359
    • McKay, C.1    McDermott, H.J.2    Vandali, A.3    Clark, G.M.4
  • 11
    • 0026719968 scopus 로고
    • A new portable sound processor for the University of Melbourne/Nucleus limited multiclcc-trode cochlear implant
    • McDermott HJ, McKay CM, Vandali AE: A new portable sound processor for the University of Melbourne/Nucleus limited multiclcc-trode cochlear implant. J Acoust Soc Am 1992: 91:3367-3371.
    • (1992) J Acoust Soc Am , vol.91 , pp. 3367-3371
    • McDermott, H.J.1    McKay, C.M.2    Vandali, A.E.3
  • 13
    • 0027493144 scopus 로고
    • Design and evaluation of a continuous interleaved sampling (CIS) processing strategy for multichannel cochlear implants
    • Wilson BS, Finley CC, Lawson DT, Wolford RD, Zerbi M: Design and evaluation of a continuous interleaved sampling (CIS) processing strategy for multichannel cochlear implants. J Rehabil Res Dev 1993:30:116-125.
    • (1993) J Rehabil Res Dev , vol.30 , pp. 116-125
    • Wilson, B.S.1    Finley, C.C.2    Lawson, D.T.3    Wolford, R.D.4    Zerbi, M.5
  • 14
    • 0029267320 scopus 로고
    • Electronic design of a cochlear implant for multichannel high-rate pulsatile stimulation strategies
    • Zierhofer CM, Hochmair IJ, Hochmair ES: Electronic design of a cochlear implant for multichannel high-rate pulsatile stimulation strategies. IEEE Trans Rehabil Engr 1995:3:112-116.
    • (1995) IEEE Trans Rehabil Engr , vol.3 , pp. 112-116
    • Zierhofer, C.M.1    Hochmair, I.J.2    Hochmair, E.S.3
  • 16
    • 15844416925 scopus 로고
    • The performance of the Nucleus Spectra 22 and the Clarion CIS devices in quiet and in noise (Abstract)
    • Battmer RD, Lenarz T: The performance of the Nucleus Spectra 22 and the Clarion CIS devices in quiet and in noise (abstract). IIIrd Paris Int Cochlear Implant Conf 1995. p 330.
    • (1995) Iiird Paris Int Cochlear Implant Conf , pp. 330
    • Battmer, R.D.1    Lenarz, T.2
  • 17
    • 0027230715 scopus 로고
    • Clarion cochlear implant: Phase I investigational results
    • Schindler RA, Kessler DK: Clarion cochlear implant: Phase I investigational results. Am J Otol 1993;14:263-272.
    • (1993) Am J Otol , vol.14 , pp. 263-272
    • Schindler, R.A.1    Kessler, D.K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.