메뉴 건너뛰기




Volumn 1, Issue , 2004, Pages 456-461

Analysis of the effects of load cycling and thermal transients on polymer-insulated HVAC cable life

Author keywords

[No Author keywords available]

Indexed keywords

DIELECTRIC MATERIALS; ELECTRIC CABLES; ELECTRIC CONDUCTORS; ELECTRIC CURRENTS; ELECTRIC INSULATION; ELECTRIC POTENTIAL; INTERFACES (MATERIALS);

EID: 15844368655     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (16)

References (9)
  • 1
    • 0028524025 scopus 로고
    • Development of 500-kV XLPE cables and accessories for long distance underground transmission line. Part 1. Insulation design of cables
    • October
    • T. Kubota, Y. Takahashi, S. Sakuma, M. Watanabe, M. Kanaoka, H. Yamanouchi, "Development of 500-kV XLPE cables and accessories for long distance underground transmission Line. Part 1. Insulation design of cables", IEEE Trans. Power Delivery, vol. 9, no. 4, pp.1738-1749, October 1994.
    • (1994) IEEE Trans. Power Delivery , vol.9 , Issue.4 , pp. 1738-1749
    • Kubota, T.1    Takahashi, Y.2    Sakuma, S.3    Watanabe, M.4    Kanaoka, M.5    Yamanouchi, H.6
  • 3
    • 15844363436 scopus 로고
    • Current ratings of cables for cyclic and emergency loads. Part 1. Cyclic ratings (load factor less than 100%) and response to a step function
    • CIGRE paper: October
    • CIGRE paper: "Current ratings of cables for cyclic and emergency loads. Part 1. Cyclic ratings (load factor less than 100%) and response to a step function", Electro, no. 24, pp. 63-96, October 1972.
    • (1972) Electro , Issue.24 , pp. 63-96
  • 4
    • 15844371532 scopus 로고
    • Current ratings of cables for cyclic and emergency loads. Part 2. Emergency ratings and short duration response to a step function
    • CIGRE paper: January
    • CIGRE paper: "Current ratings of cables for cyclic and emergency loads. Part 2. Emergency ratings and short duration response to a step function", Electro, no. 44, pp. 3-16, January 1976.
    • (1976) Electro , Issue.44 , pp. 3-16
  • 5
    • 0026941532 scopus 로고
    • Transient ratings of buried power cables. Part 1: Historical perspective and mathematical model
    • October
    • G.J. Anders, M.A. El-Kady, "Transient ratings of buried power cables. Part 1: historical perspective and mathematical model", IEEE Trans. Power Delivery, vol. 7, no. 4, pp.1724-1734, October 1992.
    • (1992) IEEE Trans. Power Delivery , vol.7 , Issue.4 , pp. 1724-1734
    • Anders, G.J.1    El-Kady, M.A.2
  • 6
    • 85115243338 scopus 로고
    • Cumulative damage in fatigue
    • September
    • M. A. Miner, "Cumulative damage in fatigue", J. Appl. Mechanics, pp. A159-A163, September 1945.
    • (1945) J. Appl. Mechanics
    • Miner, M.A.1
  • 7
    • 0036817808 scopus 로고    scopus 로고
    • Progress in electrothermal life modeling of electrical insulation over the last decades
    • October
    • G.C. Montanari, G. Mazzanti, L. Simoni, "Progress in electrothermal life modeling of electrical insulation over the last decades", IEEE Trans. Diel. El. Insul., vol. 9, no. 5, pp. 730-745, October 2002.
    • (2002) IEEE Trans. Diel. El. Insul. , vol.9 , Issue.5 , pp. 730-745
    • Montanari, G.C.1    Mazzanti, G.2    Simoni, L.3
  • 8
    • 0030735645 scopus 로고    scopus 로고
    • A comparison between XLPE and EPR as insulating materials for HV cables
    • January
    • G. Mazzanti, G.C. Montanari, "A comparison between XLPE and EPR as insulating materials for HV cables", IEEE Trans. Pow. Del., vol. 12, no. 1, pp. 15-28, January 1997.
    • (1997) IEEE Trans. Pow. Del. , vol.12 , Issue.1 , pp. 15-28
    • Mazzanti, G.1    Montanari, G.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.