메뉴 건너뛰기




Volumn 46, Issue 9-10, 2005, Pages 1595-1611

An algorithmic approach towards finding better refrigerant substitutes of CFCs in terms of the second law of thermodynamics

Author keywords

CFC replacements; Irreversibility; Rational efficiency; REFPROP; Refrigerant mixtures

Indexed keywords

ALGORITHMS; BINARY MIXTURES; CHLOROFLUOROCARBONS; CONDENSERS (LIQUEFIERS); COOLING SYSTEMS; ENTROPY; EVAPORATORS; HEAT EXCHANGERS; HEAT TRANSFER; PRESSURE EFFECTS; SPECIFIC HEAT; THERMODYNAMICS;

EID: 15744392946     PISSN: 01968904     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.enconman.2004.07.012     Document Type: Article
Times cited : (23)

References (21)
  • 1
    • 0029406105 scopus 로고
    • A method for the prediction of vapor-liquid equilibria of refrigerant mixtures at low and moderate pressure
    • M. Barolo, A. Bertucco, and G. Scalabrin A method for the prediction of vapor-liquid equilibria of refrigerant mixtures at low and moderate pressure Int. J. Refrig. 18 1995 550 556
    • (1995) Int. J. Refrig. , vol.18 , pp. 550-556
    • Barolo, M.1    Bertucco, A.2    Scalabrin, G.3
  • 2
    • 0033727739 scopus 로고    scopus 로고
    • Binary and ternary blends of R-134a as alternative refrigerants to R-22
    • A. Stegou-Sagia, and M. Damanakis Binary and ternary blends of R-134a as alternative refrigerants to R-22 Energy Convers. Manage. 41 2000 1345 1359
    • (2000) Energy Convers. Manage. , vol.41 , pp. 1345-1359
    • Stegou-Sagia, A.1    Damanakis, M.2
  • 3
    • 0032757280 scopus 로고    scopus 로고
    • Determination of optimum working conditions in heat pumps using nonazeotropic refrigerant mixtures
    • Ö. ÇomaklI, C. Çelik, and S. Erdoǧan Determination of optimum working conditions in heat pumps using nonazeotropic refrigerant mixtures Energy Convers. Manage. 40 1999 193 203
    • (1999) Energy Convers. Manage. , vol.40 , pp. 193-203
    • Çomakli, Ö.1    Çelik, C.2    Erdoǧan, S.3
  • 4
    • 38149144684 scopus 로고
    • A computer simulation program for mixed-refrigerant air conditioning
    • G.G. Haselden, and J. Chen A computer simulation program for mixed-refrigerant air conditioning Int. J. Refrig. 17 1994 343 350
    • (1994) Int. J. Refrig. , vol.17 , pp. 343-350
    • Haselden, G.G.1    Chen, J.2
  • 5
    • 0000022206 scopus 로고    scopus 로고
    • The Optimal design of refrigerant mixtures for a two-evaporator refrigeration system
    • N. Churi, and L.E.K. Achenie The Optimal design of refrigerant mixtures for a two-evaporator refrigeration system Comp. Chem. Eng. 21 1997 349 354
    • (1997) Comp. Chem. Eng. , vol.21 , pp. 349-354
    • Churi, N.1    Achenie, L.E.K.2
  • 6
    • 0030151402 scopus 로고    scopus 로고
    • Behaviour and performances of R502 alternative working fluids in refrigerating plants
    • C. Aprea, and R. Mastrullo Behaviour and performances of R502 alternative working fluids in refrigerating plants Int. J. Refrig. 19 1996 257 263
    • (1996) Int. J. Refrig. , vol.19 , pp. 257-263
    • Aprea, C.1    Mastrullo, R.2
  • 7
    • 0026169069 scopus 로고
    • Second-law analysis of solar-assisted heat pumps
    • S.K. Chaturvedi, T.O. Mohieldin, and D.T. Chen Second-law analysis of solar-assisted heat pumps Energy 16 1991 941 949
    • (1991) Energy , vol.16 , pp. 941-949
    • Chaturvedi, S.K.1    Mohieldin, T.O.2    Chen, D.T.3
  • 8
    • 0026174062 scopus 로고
    • Irreversibility analysis of a water-to-water mechanical-compression heat pump
    • H. Liang, and T.H. Kuehn Irreversibility analysis of a water-to-water mechanical-compression heat pump Energy 16 1991 883 896
    • (1991) Energy , vol.16 , pp. 883-896
    • Liang, H.1    Kuehn, T.H.2
  • 9
    • 0030290313 scopus 로고    scopus 로고
    • Second-law-based thermodynamic analysis of two-stage and mechanical-subcooling refrigeration cycles
    • S.M. Zubair, M. Yaqub, and S.H. Khan Second-law-based thermodynamic analysis of two-stage and mechanical-subcooling refrigeration cycles Int. J. Refrig. 19 1996 506 516
    • (1996) Int. J. Refrig. , vol.19 , pp. 506-516
    • Zubair, S.M.1    Yaqub, M.2    Khan, S.H.3
  • 10
    • 43949154025 scopus 로고
    • Glide matching with binary and ternary zeotropic refrigerant mixtures
    • P.A. Domanski, W.J. Mulroy, and D.A. Didion Glide matching with binary and ternary zeotropic refrigerant mixtures Int. J. Refrig. 17 1994 226 230
    • (1994) Int. J. Refrig. , vol.17 , pp. 226-230
    • Domanski, P.A.1    Mulroy, W.J.2    Didion, D.A.3
  • 14
    • 0026191095 scopus 로고
    • Performance simulation of single evaporator refrigerator with pure and mixed refrigerants
    • D.S. Jung, and R. Radermacher Performance simulation of single evaporator refrigerator with pure and mixed refrigerants Int. J. Refrig. 14 1991 223 232
    • (1991) Int. J. Refrig. , vol.14 , pp. 223-232
    • Jung, D.S.1    Radermacher, R.2
  • 15
    • 0023453321 scopus 로고
    • Methods for comparing the performance of pure and mixed refrigerants in the vapour compression cycle
    • M.O. McLinden, and R. Radermacher Methods for comparing the performance of pure and mixed refrigerants in the vapour compression cycle Int. J. Refrig. 10 1987 318 325
    • (1987) Int. J. Refrig. , vol.10 , pp. 318-325
    • McLinden, M.O.1    Radermacher, R.2
  • 16
    • 0030704496 scopus 로고    scopus 로고
    • Experimental evaluation of refrigerant mixtures as substitutes for CFC12 and R502
    • R. Camporese, G. Bigolaro, S. Bobbo, and G. Cortella Experimental evaluation of refrigerant mixtures as substitutes for CFC12 and R502 Int. J. Refrig. 20 1997 22 31
    • (1997) Int. J. Refrig. , vol.20 , pp. 22-31
    • Camporese, R.1    Bigolaro, G.2    Bobbo, S.3    Cortella, G.4
  • 17
    • 0029232015 scopus 로고
    • The performance of propane/isobutane in a vapor-compression refrigeration system
    • R. Richardson, and J. Butterworth The performance of propane/isobutane in a vapor-compression refrigeration system Int. J. Refrig. 18 1995 58 62
    • (1995) Int. J. Refrig. , vol.18 , pp. 58-62
    • Richardson, R.1    Butterworth, J.2
  • 18
    • 0002814155 scopus 로고
    • Assessment of HFCs, fluorinated ethers and amine as alternatives to CFC12
    • S. Devotta, S. Gopichand, and V.R. Pendyala Assessment of HFCs, fluorinated ethers and amine as alternatives to CFC12 Int. J. Refrig. 16 1993 84 90
    • (1993) Int. J. Refrig. , vol.16 , pp. 84-90
    • Devotta, S.1    Gopichand, S.2    Pendyala, V.R.3
  • 19
    • 0033355603 scopus 로고    scopus 로고
    • Evaluation of supplementary/retrofit refrigerants for automobile air-conditioners charged with R12
    • D. Jung, B. Park, and H. Lee Evaluation of supplementary/retrofit refrigerants for automobile air-conditioners charged with R12 Int. J. Refrig. 22 1999 558 568
    • (1999) Int. J. Refrig. , vol.22 , pp. 558-568
    • Jung, D.1    Park, B.2    Lee, H.3
  • 20
    • 0029408744 scopus 로고
    • Vapour-liquid equilibrium of ternary mixtures of the refrigerants R32, R125 and R134a
    • M. Nagel, and K. Bier Vapour-liquid equilibrium of ternary mixtures of the refrigerants R32, R125 and R134a Int. J. Refrig. 18 1995 534 543
    • (1995) Int. J. Refrig. , vol.18 , pp. 534-543
    • Nagel, M.1    Bier, K.2
  • 21
    • 0028446822 scopus 로고
    • Performance evaluation of two azeotropic refrigerant mixtures of HFC-134a with propane and isobutane
    • M.S. Kim, W.J. Mulroy, and D.A. Didion Performance evaluation of two azeotropic refrigerant mixtures of HFC-134a with propane and isobutane J. Energy Res. Technol. 116 1994 148 154
    • (1994) J. Energy Res. Technol. , vol.116 , pp. 148-154
    • Kim, M.S.1    Mulroy, W.J.2    Didion, D.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.