Study of the impact of artificial articulations on the dose distribution under medical irradiation

Author keywords

BEAMnrc EGSnrc codes; Dose distribution; Hip prosthesis; Monte Carlo simulations; Pelvic irradiation

Indexed keywords

ATTENUATION; COMPUTER SIMULATION; HIP PROSTHESES; IONIZATION CHAMBERS; MONTE CARLO METHODS; OPTIMIZATION; RADIOTHERAPY; THERMOLUMINESCENCE;

EID: 15744390125     PISSN: 0168583X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.nimb.2004.11.005     Document Type: Article
Times cited : (11)

References (12)
  • 1
    • 0035889273 scopus 로고    scopus 로고
    • A study on beams passing through hip prosthesis for pelvic radiation treatment
    • G.X. Ding, and C.W. Yu A study on beams passing through hip prosthesis for pelvic radiation treatment Int. J. Radiat. Oncol. Biol. Phys. 51/4 2001 1167
    • (2001) Int. J. Radiat. Oncol. Biol. Phys. , vol.51 , Issue.4 , pp. 1167
    • Ding, G.X.1    Yu, C.W.2
  • 3
    • 0027475002 scopus 로고
    • Prostatic thermoluminescent dosimeter analysis in a patient treated with 18 MV X rays through a prosthetic hip
    • M.B. Hazuka, D.N. Stroud, J. Adams, G.S. Ibbott, and J.J. Kinzie Prostatic thermoluminescent dosimeter analysis in a patient treated with 18 MV X rays through a prosthetic hip Int. J. Radiat. Oncol. Biol. Phys. 25/2 1993 339
    • (1993) Int. J. Radiat. Oncol. Biol. Phys. , vol.25 , Issue.2 , pp. 339
    • Hazuka, M.B.1    Stroud, D.N.2    Adams, J.3    Ibbott, G.S.4    Kinzie, J.J.5
  • 4
    • 0038510218 scopus 로고    scopus 로고
    • Radiotherapy dose calculations in the presence of hip prostheses
    • P.J. Keall, J.V. Siebers, R. Jeraj, and R. Mohan Radiotherapy dose calculations in the presence of hip prostheses Med. Dosim. 28 2 2003 107
    • (2003) Med. Dosim. , vol.28 , Issue.2 , pp. 107
    • Keall, P.J.1    Siebers, J.V.2    Jeraj, R.3    Mohan, R.4
  • 5
    • 10744226022 scopus 로고    scopus 로고
    • Dosimetric considerations for patients with hip prostheses undergoing pelvic irradiation, Report of the AAPM Radiation Therapy Committee Task Group 63
    • C. Reft, R. Alecu, I.J. Das, B.J. Gerbi, P. Keall, E. Lief, B.J. Mijnheer, N. Papanikolaou, C. Sibata, and J. Van Dyk Dosimetric considerations for patients with hip prostheses undergoing pelvic irradiation, Report of the AAPM Radiation Therapy Committee Task Group 63 Med. Phys. 30 6 2003 1162
    • (2003) Med. Phys. , vol.30 , Issue.6 , pp. 1162
    • Reft, C.1    Alecu, R.2    Das, I.J.3    Gerbi, B.J.4    Keall, P.5    Lief, E.6    Mijnheer, B.J.7    Papanikolaou, N.8    Sibata, C.9    Van Dyk, J.10
  • 7
    • 0003797114 scopus 로고    scopus 로고
    • The EGSnrc code system: MC simulation of electron and photon transport
    • NRCC, Ottawa, Canada
    • I. Kawrakow, D.W.O. Rogers, The EGSnrc code system: MC simulation of electron and photon transport. Technical Report PIRS-701, NRCC, Ottawa, Canada, 2000
    • (2000) Technical Report , vol.PIRS-701
    • Kawrakow, I.1    Rogers, D.W.O.2
  • 9
    • 0033836680 scopus 로고    scopus 로고
    • Effect of hip prostheses on radiotherapy dose
    • M. Carolan, P. Dao, C. Fox, and P. Metcalfe Effect of hip prostheses on radiotherapy dose Australas Radiol. 44 3 2000 290
    • (2000) Australas Radiol. , vol.44 , Issue.3 , pp. 290
    • Carolan, M.1    Dao, P.2    Fox, C.3    Metcalfe, P.4
  • 10
    • 0036103853 scopus 로고    scopus 로고
    • The effect of a metal hip prosthesis on the radiation dose in therapeutic photon beam irradiation
    • S-Y. Lin, T-C. Chu, J-P. Lin, and M-T. Liu The effect of a metal hip prosthesis on the radiation dose in therapeutic photon beam irradiation Appl. Radiat. Isotopes 57 2002 17
    • (2002) Appl. Radiat. Isotopes , vol.57 , pp. 17
    • Lin, S.-Y.1    Chu, T.-C.2    Lin, J.-P.3    Liu, M.-T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.