메뉴 건너뛰기




Volumn 123, Issue 4, 2005, Pages 618-624

Performance of an automated immature granulocyte count as a predictor of neonatal sepsis

Author keywords

Automated hematology analyzer; Differential leukocyte counts; Immature granulocyte count; Left shift; Neonatal sepsis; Neutrophil band counts; Sysmex XE 2100

Indexed keywords

ARTICLE; AUTOMATION; BLOOD CELL COUNT; BLOOD CULTURE; COMPARATIVE STUDY; COMPUTER PROGRAM; CONTROLLED STUDY; GRANULOCYTE; HUMAN; HUMAN CELL; LEUKOCYTE COUNT; LEUKOCYTE DIFFERENTIAL COUNT; MAJOR CLINICAL STUDY; NEUTROPENIA; NEWBORN; NEWBORN SEPSIS; PREDICTION; PRIORITY JOURNAL; PROSPECTIVE STUDY; RESIDENT; SENSITIVITY ANALYSIS;

EID: 15744386110     PISSN: 00029173     EISSN: None     Source Type: Journal    
DOI: 10.1309/73H7K7UBW816PBJJ     Document Type: Article
Times cited : (74)

References (16)
  • 1
    • 0036130649 scopus 로고    scopus 로고
    • Clinical utility of the band count
    • Cornbleet PJ. Clinical utility of the band count. Clin Lab Med. 2002;22:101-135.
    • (2002) Clin Lab Med , vol.22 , pp. 101-135
    • Cornbleet, P.J.1
  • 2
    • 0018361814 scopus 로고
    • The neonatal blood count in health and disease, 1: Reference values for neutrophilic cells
    • Manroe BL, Weinberg AG, Rosenfeld CR, et al. The neonatal blood count in health and disease, 1: reference values for neutrophilic cells. J Pediatr. 1979;95:89-98.
    • (1979) J Pediatr , vol.95 , pp. 89-98
    • Manroe, B.L.1    Weinberg, A.G.2    Rosenfeld, C.R.3
  • 3
    • 0023937143 scopus 로고
    • Early diagnosis of neonatal sepsis using a hematologic scoring system
    • Rodwell RL, Leslie AL, Tudehope DI. Early diagnosis of neonatal sepsis using a hematologic scoring system. J Pediatr. 1988;112:761-767.
    • (1988) J Pediatr , vol.112 , pp. 761-767
    • Rodwell, R.L.1    Leslie, A.L.2    Tudehope, D.I.3
  • 4
    • 0031917112 scopus 로고    scopus 로고
    • Diagnostic tests for bacterial infection from birth to 90 days: A systematic review
    • Fowlie PW, Schmidt B. Diagnostic tests for bacterial infection from birth to 90 days: a systematic review. Arch Dis Child Fetal Neonatal Ed. 1998;78:F92-F98.
    • (1998) Arch Dis Child Fetal Neonatal Ed , vol.78
    • Fowlie, P.W.1    Schmidt, B.2
  • 5
    • 0029166188 scopus 로고
    • Clinical and laboratory observations: Differentiation of segmented and band neutrophils during the early newborn period
    • Schelonka RL, Yoder BA, Hall RB, et al. Clinical and laboratory observations: differentiation of segmented and band neutrophils during the early newborn period. J Pediatr. 1995;127:298-300.
    • (1995) J Pediatr , vol.127 , pp. 298-300
    • Schelonka, R.L.1    Yoder, B.A.2    Hall, R.B.3
  • 6
    • 0034452663 scopus 로고    scopus 로고
    • New quantitative parameters on a recently introduced automated blood cell counter: The XE 2100
    • Briggs C, Harrison P, Grant D, et al. New quantitative parameters on a recently introduced automated blood cell counter: the XE 2100. Clin Lab Haematol. 2000;22:345-350.
    • (2000) Clin Lab Haematol , vol.22 , pp. 345-350
    • Briggs, C.1    Harrison, P.2    Grant, D.3
  • 7
    • 0002020192 scopus 로고    scopus 로고
    • Precision and accuracy of the leukocyte differential on the Sysmex XE-2100
    • Herklotz R, Huber AR. Precision and accuracy of the leukocyte differential on the Sysmex XE-2100. Sysmex J Int. 2001;11:8-21.
    • (2001) Sysmex J Int , vol.11 , pp. 8-21
    • Herklotz, R.1    Huber, A.R.2
  • 8
    • 15744384732 scopus 로고    scopus 로고
    • Evaluation of the automated immature granulocyte count (IG) on Sysmex XE-2100 automated haematology analyzer vs visual microscopy (NCCLS H20-A)
    • Weiland TH, Kalkman H, Heihn H. Evaluation of the automated immature granulocyte count (IG) on Sysmex XE-2100 automated haematology analyzer vs visual microscopy (NCCLS H20-A). Sysmex J Int. 2002;12:63-70.
    • (2002) Sysmex J Int , vol.12 , pp. 63-70
    • Weiland, T.H.1    Kalkman, H.2    Heihn, H.3
  • 9
    • 0242300575 scopus 로고    scopus 로고
    • Immature granulocyte measurement using the Sysmex XE-2100: Relationship to infection and sepsis
    • Ansari-Lari MA, Kickler TS, Borowitz MJ. Immature granulocyte measurement using the Sysmex XE-2100: relationship to infection and sepsis. Am J Clin Pathol. 2003;120:795-799.
    • (2003) Am J Clin Pathol , vol.120 , pp. 795-799
    • Ansari-Lari, M.A.1    Kickler, T.S.2    Borowitz, M.J.3
  • 10
    • 0141616498 scopus 로고    scopus 로고
    • Evaluation of immature granulocyte counts by the XE-IG Master: Upgraded software for the XE-2100 automated hematology analyzer
    • Briggs C, Kunka S, Fujimoto H, et al. Evaluation of immature granulocyte counts by the XE-IG Master: upgraded software for the XE-2100 automated hematology analyzer. Lab Hematol. 2003;9:117-124.
    • (2003) Lab Hematol , vol.9 , pp. 117-124
    • Briggs, C.1    Kunka, S.2    Fujimoto, H.3
  • 11
    • 0026440373 scopus 로고
    • Total leukocyte and neutrophil count changes associated with antenatal betamethasone administration in premature infants
    • Barak M, Cohen A, Herschkowitz S. Total leukocyte and neutrophil count changes associated with antenatal betamethasone administration in premature infants. Acta Paediatr. 1992;81:760-763.
    • (1992) Acta Paediatr , vol.81 , pp. 760-763
    • Barak, M.1    Cohen, A.2    Herschkowitz, S.3
  • 12
    • 0032857885 scopus 로고    scopus 로고
    • Early dexamethasone therapy and blood cell count in preterm infants
    • Peng CT, Lin HC, Lin YJ, et al. Early dexamethasone therapy and blood cell count in preterm infants. Pediatrics. 1999;104(3 pt 1):476-481.
    • (1999) Pediatrics , vol.104 , Issue.3 PART 1 , pp. 476-481
    • Peng, C.T.1    Lin, H.C.2    Lin, Y.J.3
  • 13
    • 0023982645 scopus 로고
    • Effect of antenatal dexamethasone on neonatal leukocyte count
    • Zachman RD, Bauer CR, Boehm J, et al. Effect of antenatal dexamethasone on neonatal leukocyte count. J Perinatol. 1988;8:111-113.
    • (1988) J Perinatol , vol.8 , pp. 111-113
    • Zachman, R.D.1    Bauer, C.R.2    Boehm, J.3
  • 14
    • 0018895768 scopus 로고
    • Exhaustion of mature marrow neutrophils in neonates with sepsis
    • Christensen RD, Rothstein G. Exhaustion of mature marrow neutrophils in neonates with sepsis. J Pediatr. 1980;96:316-318.
    • (1980) J Pediatr , vol.96 , pp. 316-318
    • Christensen, R.D.1    Rothstein, G.2
  • 15
    • 0020059447 scopus 로고
    • Supply and release of storage neutrophils: A developmental study
    • Erdman SH, Christensen RD, Bradley PP, et al. Supply and release of storage neutrophils: a developmental study. Biol Neonate. 1982;41:132-137.
    • (1982) Biol Neonate , vol.41 , pp. 132-137
    • Erdman, S.H.1    Christensen, R.D.2    Bradley, P.P.3
  • 16
    • 0015411175 scopus 로고
    • Blood neutrophil response to bacterial infection in the first month of life
    • Gregory J, Hey E. Blood neutrophil response to bacterial infection in the first month of life. Arch Dis Child. 1972;47:747-753.
    • (1972) Arch Dis Child , vol.47 , pp. 747-753
    • Gregory, J.1    Hey, E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.