메뉴 건너뛰기




Volumn 68, Issue 6, 1997, Pages 571-576

Improved osseointeraction of calcium phosphate-coated external fixation pins

Author keywords

[No Author keywords available]

Indexed keywords

CALCIUM PHOSPHATE; MEDRONATE TECHNETIUM TC 99M;

EID: 15644370611     PISSN: 00016470     EISSN: None     Source Type: Journal    
DOI: 10.3109/17453679708999029     Document Type: Article
Times cited : (15)

References (22)
  • 1
    • 0023953712 scopus 로고
    • Bone mineral content and mechanical strength
    • Alho A, Husby T, Hoiseth A. Bone mineral content and mechanical strength. Clin Orthop 1988; 227: 292-7.
    • (1988) Clin Orthop , vol.227 , pp. 292-297
    • Alho, A.1    Husby, T.2    Hoiseth, A.3
  • 2
    • 0027435284 scopus 로고
    • Cortical bone reactions at the interface of external fixation half-pins under different loading conditions
    • Aro H T, Markel M D, Chao E Y S. Cortical bone reactions at the interface of external fixation half-pins under different loading conditions. J Trauma 1993; 35 (5): 776-85.
    • (1993) J Trauma , vol.35 , Issue.5 , pp. 776-785
    • Aro, H.T.1    Markel, M.D.2    Chao, E.Y.S.3
  • 3
    • 0020823258 scopus 로고
    • Osseointegration and its experimental background
    • Branemark P. Osseointegration and its experimental background. J Prosthet Dent 1983; 50; 399-410.
    • (1983) J Prosthet Dent , vol.50 , pp. 399-410
    • Branemark, P.1
  • 4
    • 0021489125 scopus 로고
    • The medical-physiological potential of plasma-sprayed ceramic coatings
    • Brown S D. The medical-physiological potential of plasma-sprayed ceramic coatings. Thin Solid Films 1984; 119: 127-39.
    • (1984) Thin Solid Films , vol.119 , pp. 127-139
    • Brown, S.D.1
  • 5
    • 0027605115 scopus 로고
    • Histomorphometric assessment of the mechanisms for rapid ingrowth of bone to HA/TCP coated implants
    • Burr D B, Mori S, Boyd R D, et al. Histomorphometric assessment of the mechanisms for rapid ingrowth of bone to HA/TCP coated implants. J Biomed Mater Res 1993; 27: 645-53.
    • (1993) J Biomed Mater Res , vol.27 , pp. 645-653
    • Burr, D.B.1    Mori, S.2    Boyd, R.D.3
  • 6
    • 0026908619 scopus 로고
    • Hydroxyapatite coating of porous implants improves bone ingrowth and interface attachment strength
    • Cook S D, Thomas K A, Dalton J E, et al. Hydroxyapatite coating of porous implants improves bone ingrowth and interface attachment strength. J Biomed Mater Res 1992; 26: 989-1001.
    • (1992) J Biomed Mater Res , vol.26 , pp. 989-1001
    • Cook, S.D.1    Thomas, K.A.2    Dalton, J.E.3
  • 7
    • 0025124071 scopus 로고
    • Effect of calcium phosphate coating characteristics on early post-operative bone tissue ingrowth
    • Ducheyne P, Beight J, Cuckler J, et al. Effect of calcium phosphate coating characteristics on early post-operative bone tissue ingrowth. Biomaterials 1990; 11: 531-40.
    • (1990) Biomaterials , vol.11 , pp. 531-540
    • Ducheyne, P.1    Beight, J.2    Cuckler, J.3
  • 8
    • 84995127643 scopus 로고
    • Effect of fixation pin insertion on the bone-pin interface
    • Egger E L, Histand M B, Blass C E, et al. Effect of fixation pin insertion on the bone-pin interface. Vet Surg 1986; 15: 246-52.
    • (1986) Vet Surg , vol.15 , pp. 246-252
    • Egger, E.L.1    Histand, M.B.2    Blass, C.E.3
  • 9
    • 0025608937 scopus 로고
    • Hydroxyapatite-coated total hip prostheses: Two-year clinical and roentgenographic results of 100 cases
    • Geesink R. Hydroxyapatite-coated total hip prostheses: Two-year clinical and roentgenographic results of 100 cases. Clin Orthop 1990; 261: 39-58.
    • (1990) Clin Orthop , vol.261 , pp. 39-58
    • Geesink, R.1
  • 10
    • 0021059815 scopus 로고
    • Complications of external skeletal fixation
    • Green S A. Complications of external skeletal fixation. Clin Orthop 1983; 180: 109-16.
    • (1983) Clin Orthop , vol.180 , pp. 109-116
    • Green, S.A.1
  • 12
    • 0024764129 scopus 로고
    • Evaluation of metal implants coated with several types of ceramics as biomaterials
    • Hayashi K, Matsuguchi N, Uenoyama K, et al. Evaluation of metal implants coated with several types of ceramics as biomaterials. J Biomed Mater Res 1989; 23: 1247-59.
    • (1989) J Biomed Mater Res , vol.23 , pp. 1247-1259
    • Hayashi, K.1    Matsuguchi, N.2    Uenoyama, K.3
  • 13
    • 0027670349 scopus 로고
    • Histological and histomorphometrical evaluation of the hone reaction to three different titanium alloy and hydroxyapatite coated implants
    • Jansen J A, van der Waerden JPC, Wolke J G C. Histological and histomorphometrical evaluation of the hone reaction to three different titanium alloy and hydroxyapatite coated implants. J Appl Biomater 1993; 4: 213-9.
    • (1993) J Appl Biomater , vol.4 , pp. 213-219
    • Jansen, J.A.1    Van Der Waerden, J.P.C.2    Wolke, J.G.C.3
  • 14
    • 0023765128 scopus 로고
    • Quantitative digital radiography versus dual photon absorptiometry of the lumbar spine
    • Kelly T L, Slovik D M, Schoenfeld D A, et al. Quantitative digital radiography versus dual photon absorptiometry of the lumbar spine. J Clin Endocrinol Metab 1988; 67: 839-44.
    • (1988) J Clin Endocrinol Metab , vol.67 , pp. 839-844
    • Kelly, T.L.1    Slovik, D.M.2    Schoenfeld, D.A.3
  • 15
    • 0023759924 scopus 로고
    • Hydroxyapatite coatings
    • Lemmons J E. Hydroxyapatite coatings. Clin Orthop 1988; 235: 220-3.
    • (1988) Clin Orthop , vol.235 , pp. 220-223
    • Lemmons, J.E.1
  • 16
    • 0021169798 scopus 로고
    • The thermal effects of skeletal fixation-pin insertion in bone
    • Matthews L S, Green C A, Goldstein S A. The thermal effects of skeletal fixation-pin insertion in bone. J Bone Joint Surg (Am) 1984; 66: 1077-83.
    • (1984) J Bone Joint Surg (Am) , vol.66 , pp. 1077-1083
    • Matthews, L.S.1    Green, C.A.2    Goldstein, S.A.3
  • 17
    • 0024307640 scopus 로고
    • Infection after intramedullary nailing of severe open tibial fractures initially treated with external fixation
    • Maurer D J, Merkow R L, Gustilo R B. Infection after intramedullary nailing of severe open tibial fractures initially treated with external fixation. J Bone Joint Surg (Am) 1989; 71: 835-8.
    • (1989) J Bone Joint Surg (Am) , vol.71 , pp. 835-838
    • Maurer, D.J.1    Merkow, R.L.2    Gustilo, R.B.3
  • 18
    • 0027703726 scopus 로고
    • Osteogenic differentiation of marrow stromal stem cells in porous hydroxyapatite ceramics
    • Ohgushi H, Dohi Y, Tamai S, et al. Osteogenic differentiation of marrow stromal stem cells in porous hydroxyapatite ceramics. J Biomed Mater Res 1993; 27: 1401-7.
    • (1993) J Biomed Mater Res , vol.27 , pp. 1401-1407
    • Ohgushi, H.1    Dohi, Y.2    Tamai, S.3
  • 19
    • 0026832935 scopus 로고
    • Tissue ingrowth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions
    • Soballe K, Hansen E S, B.-Rasmussen H, et al. Tissue ingrowth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions. J Orthop Res 1992; 10: 285-99.
    • (1992) J Orthop Res , vol.10 , pp. 285-299
    • Soballe, K.1    Hansen, E.S.2    B.-Rasmussen, H.3
  • 20
    • 0029347538 scopus 로고
    • Quantitative analysis of the bone-hydroxyapatite coaling interface
    • Stea S, Visentin M, Savarino L, et al. Quantitative analysis of the bone-hydroxyapatite coaling interface. J Materials Sci: Mater Med 1995; 6: 455-9.
    • (1995) J Materials Sci: Mater Med , vol.6 , pp. 455-459
    • Stea, S.1    Visentin, M.2    Savarino, L.3
  • 21
    • 15644377958 scopus 로고
    • The effect of storage of excised bone on measurement of bone mineral using dual-energy x-ray absorptiometry (DXA) (Abstract)
    • Toll P W, Anderson D E, Berryhill S A, et al. The effect of storage of excised bone on measurement of bone mineral using dual-energy x-ray absorptiometry (DXA) (Abstract). J Bone Miner Res (Suppl 1) 1994; 9: 174.
    • (1994) J Bone Miner Res , vol.9 , Issue.1 SUPPL. , pp. 174
    • Toll, P.W.1    Anderson, D.E.2    Berryhill, S.A.3
  • 22
    • 0025411162 scopus 로고
    • The biocompatability of hydroxyapatite ceramic: A study of retrieved human middle ear implants
    • van Blitterswijk C A, Hesseling S C, Grote J J, et al. The biocompatability of hydroxyapatite ceramic: a study of retrieved human middle ear implants. J Biomed Mater Res 1990; 24: 433-53.
    • (1990) J Biomed Mater Res , vol.24 , pp. 433-453
    • Blitterswijk, C.A.1    Hesseling, S.C.2    Grote, J.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.