An unusual case of guidewire impaction during internal jugular venous cannulation [8]

Author keywords

[No Author keywords available]

Indexed keywords

ARTIFICIAL EMBOLISM; CANNULATION; CATHETER INFECTION; CENTRAL VENOUS CATHETERIZATION; GUIDE WIRE; HISTOPATHOLOGY; INTERNAL JUGULAR VEIN; LETTER; NEEDLE; NEEDLE BIOPSY; PRIORITY JOURNAL; TECHNIQUE; VEIN PUNCTURE;

EID: 15544374911     PISSN: 00032999     EISSN: None     Source Type: Journal    
DOI: 10.1213/01.ANE.0000149012.22125.B8     Document Type: Letter
Times cited : (5)

References (4)
  • 1
    • 1642541768 scopus 로고    scopus 로고
    • Technique of retrieval of J-tip guidewire without withdrawing introducer needle during central venous cannulation by Seldinger technique
    • Arya VK, Kumar A. Technique of retrieval of J-tip guidewire without withdrawing introducer needle during central venous cannulation by Seldinger technique. Anesth Analg 2004;98:553-4.
    • (2004) Anesth Analg , vol.98 , pp. 553-554
    • Arya, V.K.1    Kumar, A.2
  • 2
    • 2442713397 scopus 로고
    • Catheter replacement of needle in percutaneous arteriography
    • Seldinger SI. Catheter replacement of needle in percutaneous arteriography. Acta Radiol 1953;39:368.
    • (1953) Acta Radiol , vol.39 , pp. 368
    • Seldinger, S.I.1
  • 3
    • 85047465088 scopus 로고    scopus 로고
    • Failure to advance the guidewire when the Seldinger technique is used for central venous cannulation: Safe and reliable
    • Henderson JJ. Failure to advance the guidewire when the Seldinger technique is used for central venous cannulation: safe and reliable. Anesth Analg 2004;99:620-30.
    • (2004) Anesth Analg , vol.99 , pp. 620-630
    • Henderson, J.J.1
  • 4
    • 0030210702 scopus 로고    scopus 로고
    • A sticky problem with a guidewire
    • Mitchell N. A sticky problem with a guidewire. Anaesthesia 1996;51:799.
    • (1996) Anaesthesia , vol.51 , pp. 799
    • Mitchell, N.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.