2
-
-
0013920022
-
The low frequency response of electrocardiographs: A frequent source of recording errors
-
BERSON, A. S., and PIPBERGER, H. V., 1996, The low frequency response of electrocardiographs: a frequent source of recording errors. American Heart Journal, 71, 779-789.
-
(1996)
American Heart Journal
, vol.71
, pp. 779-789
-
-
Berson, A.S.1
Pipberger, H.V.2
-
3
-
-
0014114883
-
Electrocadiographic distortions caused by inadequate high-frequency response of direct-writing electrocardiographs
-
BERSON, A. S., and PIPBERGER, H. V., 1967, Electrocadiographic distortions caused by inadequate high-frequency response of direct-writing electrocardiographs. American Heart Journal, 74, 208-218.
-
(1967)
American Heart Journal
, vol.74
, pp. 208-218
-
-
Berson, A.S.1
Pipberger, H.V.2
-
4
-
-
0020767564
-
Signal distortion in the electrocardiogram due to inadequate phase response
-
TAYLER, D., and VINCENT, R., 1983, Signal distortion in the electrocardiogram due to inadequate phase response. IEEE Transactions on Biomedical Engineering, 30, 352-356.
-
(1983)
IEEE Transactions on Biomedical Engineering
, vol.30
, pp. 352-356
-
-
Tayler, D.1
Vincent, R.2
-
6
-
-
0021491391
-
Microprocessor controlled signal generator for functional testing of electrocardiographs
-
EVAN, A. L., 1984, Microprocessor controlled signal generator for functional testing of electrocardiographs. Medical & Biological Engineering & Computing, 22, 468-470.
-
(1984)
Medical & Biological Engineering & Computing
, vol.22
, pp. 468-470
-
-
Evan, A.L.1
-
7
-
-
0000774798
-
Use of microprocessor to simulate electrocardiogram
-
MARVELL, C. J., and KIRK, D. J., 1980, Use of microprocessor to simulate electrocardiogram. Journal of Biomedical Engineering, 2, 217-220.
-
(1980)
Journal of Biomedical Engineering
, vol.2
, pp. 217-220
-
-
Marvell, C.J.1
Kirk, D.J.2
-
8
-
-
0001127258
-
An analysis of the time relations of the electrocardiogram
-
BAZETT, H. C., 1920, An analysis of the time relations of the electrocardiogram. Heart, 7, 353-370.
-
(1920)
Heart
, vol.7
, pp. 353-370
-
-
Bazett, H.C.1
-
10
-
-
0000813319
-
The normal Q-T interval
-
SIMONSON, E., and LD, J., 1962, The normal Q-T interval. American Heart Journal, 63, 747.
-
(1962)
American Heart Journal
, vol.63
, pp. 747
-
-
Simonson, E.1
Ld, J.2
-
12
-
-
0000528643
-
Normal duration of the electrocardiographic ventricular complex
-
ADAMS, W., 1936, Normal duration of the electrocardiographic ventricular complex. Journal of Clinical Investigation, 15, 335.
-
(1936)
Journal of Clinical Investigation
, vol.15
, pp. 335
-
-
Adams, W.1
-
13
-
-
0019450149
-
The relationship between the QT interval and the heart rate during physiological exercise and pacing
-
AKHRAS, F., and RICKARD, A., 1981, The relationship between the QT interval and the heart rate during physiological exercise and pacing. Japanese Heart Journal, 22, 345.
-
(1981)
Japanese Heart Journal
, vol.22
, pp. 345
-
-
Akhras, F.1
Rickard, A.2
-
14
-
-
0022256548
-
The duration of the Q-T interval as a function of heart rate
-
SANDOR, J., and LOUIS, S., 1985, The duration of the Q-T interval as a function of heart rate. American Heart Journal, 110, 872-876.
-
(1985)
American Heart Journal
, vol.110
, pp. 872-876
-
-
Sandor, J.1
Louis, S.2
-
15
-
-
84930883886
-
A QRS preprocessor based on digital differentiation
-
HOLSINGER, W. P., KEMPNER, K. M., and MILLER, M. H., 1971, A QRS preprocessor based on digital differentiation. IEEE Transactions on Biomedical Engineering, 18, 212-217.
-
(1971)
IEEE Transactions on Biomedical Engineering
, vol.18
, pp. 212-217
-
-
Holsinger, W.P.1
Kempner, K.M.2
Miller, M.H.3
-
16
-
-
0017101880
-
A digital QRS detector based on the principle of contour limiting
-
GOOVAERTS, H. G., Ros, H. H., VAN DEN AKKER, T. J., and SCHNEIDER, H., 1976, A digital QRS detector based on the principle of contour limiting. IEEE Transactions on Biomedical Engineering, 23, 154-160.
-
(1976)
IEEE Transactions on Biomedical Engineering
, vol.23
, pp. 154-160
-
-
Goovaerts, H.G.1
Ros, H.H.2
Van Den Akker, T.J.3
Schneider, H.4
-
17
-
-
0018518924
-
Microprocessor detection of electrocardiogram R-waves
-
COLEMAN, J. D., and BOLTON, M. P., 1979, Microprocessor detection of electrocardiogram R-waves. Journal of Medical Engineering and Technology, 3, 235-241.
-
(1979)
Journal of Medical Engineering and Technology
, vol.3
, pp. 235-241
-
-
Coleman, J.D.1
Bolton, M.P.2
-
18
-
-
0015329609
-
QRS-wave detector evaluation
-
VINCENT, G. M., WEBB, G. N., Ross, R. S., and GUIER, W. H., 1972, QRS-wave detector evaluation. American Heart Journal, 83, 475-480.
-
(1972)
American Heart Journal
, vol.83
, pp. 475-480
-
-
Vincent, G.M.1
Webb, G.N.2
Ross, R.S.3
Guier, W.H.4
-
19
-
-
0020211552
-
Design and evaluation of QRS and noise detectors for ambulatory ECG monitors
-
THAKOR, N. V., and WEBSTER, J. G., 1982, Design and evaluation of QRS and noise detectors for ambulatory ECG monitors. Medical & Biological Engineering & Computing, 20, 709-714.
-
(1982)
Medical & Biological Engineering & Computing
, vol.20
, pp. 709-714
-
-
Thakor, N.V.1
Webster, J.G.2
-
20
-
-
0015868634
-
Template Waveform Recognition Applied to ECG Analysis
-
VAN BEMEL, J. H., and TALMAN, J. L., 1973, Template Waveform Recognition Applied to ECG Analysis. Computers in Biomedical Research, 6, 430.
-
(1973)
Computers in Biomedical Research
, vol.6
, pp. 430
-
-
Van Bemel, J.H.1
Talman, J.L.2
-
21
-
-
0021892974
-
Adaptive QRS detection: A study of performance
-
SORNMO, L., PAHL, O., and NYGARDS, M., 1985, Adaptive QRS detection: a study of performance. IEEE Transactions in Biomedical Engineering, 32, 392-401.
-
(1985)
IEEE Transactions in Biomedical Engineering
, vol.32
, pp. 392-401
-
-
Sornmo, L.1
Pahl, O.2
Nygards, M.3
-
22
-
-
0343445370
-
Matched filter location of ECG complexes
-
Southampton (London: IERE)
-
MONDS, F. C., and TELFORD, R. W., 1976, Matched filter location of ECG complexes. IERE Conference on Application of Electronics in Medicine, Southampton (London: IERE), 111-118.
-
(1976)
IERE Conference on Application of Electronics in Medicine
, pp. 111-118
-
-
Monds, F.C.1
Telford, R.W.2
-
23
-
-
0027471770
-
Time-Frequency mapping of the heart-rate, blood pressure and respiratory signals
-
NOVAK, P., and NOVAK, V., 1993, Time-Frequency mapping of the heart-rate, blood pressure and respiratory signals. Medical & Biological Engineering & Computing, 31, 103-110.
-
(1993)
Medical & Biological Engineering & Computing
, vol.31
, pp. 103-110
-
-
Novak, P.1
Novak, V.2
-
24
-
-
0002002419
-
Detection and classification of ECG signals in the time-frequency domain
-
ABEYKERA, S. S., 1994, Detection and classification of ECG signals in the time-frequency domain. Applied Signal Processing, 1, 35-51.
-
(1994)
Applied Signal Processing
, vol.1
, pp. 35-51
-
-
Abeykera, S.S.1
-
25
-
-
0026624202
-
Time-scale analysis of high-resolution signal-averaged surface ECG using wavelet transform
-
IEEE New York: Computer Society
-
MORLET, D., and PEYRIN, F., 1991, Time-scale analysis of high-resolution signal-averaged surface ECG using wavelet transform. Proceedings of Conference on Computers in Cardiology (IEEE New York: Computer Society), 393-396.
-
(1991)
Proceedings of Conference on Computers in Cardiology
, pp. 393-396
-
-
Morlet, D.1
Peyrin, F.2
-
26
-
-
0042047036
-
Wavelet analysis of cardiovascular signals
-
edited by C. Holt, P. Grant and W. Sandham (Amsterdam: Elsevier Science)
-
BENTLY, P., and MCDONNEL, E., 1994, Wavelet analysis of cardiovascular signals. In Signal Processing Vol. 7, edited by C. Holt, P. Grant and W. Sandham (Amsterdam: Elsevier Science), pp. 78-81.
-
(1994)
Signal Processing Vol. 7
, vol.7
, pp. 78-81
-
-
Bently, P.1
McDonnel, E.2
-
27
-
-
0026561926
-
Wavelet transform as a potential tool for ECG analysis and compression
-
CROWE, J., and GIBSON, N., 1992, Wavelet transform as a potential tool for ECG analysis and compression. Journal of Biomedical Engineering, 14, 168-272.
-
(1992)
Journal of Biomedical Engineering
, vol.14
, pp. 168-272
-
-
Crowe, J.1
Gibson, N.2
-
28
-
-
33749761735
-
Adaptive noise removal from complex signals using wavelet transform
-
ROBERT, R. S., and CHAUMERON, T., 1994, Adaptive noise removal from complex signals using wavelet transform. Proceedings of the European Association of Signal Processing, 10, 66-69.
-
(1994)
Proceedings of the European Association of Signal Processing
, vol.10
, pp. 66-69
-
-
Robert, R.S.1
Chaumeron, T.2
-
29
-
-
0012536834
-
Continuous wavelet transform: ECG recognition based on phase and modulus representation
-
edited by A. Akram and M. Unser (New York: CRC Press)
-
SENDHANDJI, L., and THORVAL, L., 1996, Continuous wavelet transform: ECG recognition based on phase and modulus representation. In Wavelets in Medicine and Biology, edited by A. Akram and M. Unser (New York: CRC Press), pp. 439-463.
-
(1996)
Wavelets in Medicine and Biology
, pp. 439-463
-
-
Sendhandji, L.1
Thorval, L.2
-
30
-
-
0000562670
-
Decomposition of the Hardy function into square integrable wavelets of constant shape
-
GROSSMANN, A., and MORLET, J., 1984, Decomposition of the Hardy function into square integrable wavelets of constant shape. Siam Journal of Mathematical Analysis, 15, 723-736.
-
(1984)
Siam Journal of Mathematical Analysis
, vol.15
, pp. 723-736
-
-
Grossmann, A.1
Morlet, J.2
-
31
-
-
84898785264
-
Characterization of signals from multiscale edges
-
MALLAT, S. G., and ZHONG, S., 1992, Characterization of signals from multiscale edges. IEEE Transactions on Pattern Analysis and Machine Intelligence, 14, 710-732.
-
(1992)
IEEE Transactions on Pattern Analysis and Machine Intelligence
, vol.14
, pp. 710-732
-
-
Mallat, S.G.1
Zhong, S.2
-
32
-
-
0026686049
-
Singularity detection and processing with wavelets
-
MALLAT, S. G., and HWANG, W. L., 1992, Singularity detection and processing with wavelets. IEEE Transactions an Information Theory, 38, 617-643.
-
(1992)
IEEE Transactions An Information Theory
, vol.38
, pp. 617-643
-
-
Mallat, S.G.1
Hwang, W.L.2
-
33
-
-
0001904877
-
AHA Committee Report: Recommendations for standardization of leads and of specifications for instruments in electrocardiography and vectorcardiography
-
PIPBERGER, H. V., ARZBAECHER, R. C., BERSON, A. S., BRILLER, S. A., BRODY, D. A., FLOWERS, N. C., GIESELOWITZ, D. B., LEPESCHKIN, E., OLIVER, G. C., SCHMITT, O. H., and SPACH, M. 1975, AHA Committee Report: Recommendations for standardization of leads and of specifications for instruments in electrocardiography and vectorcardiography. Circulation, 52, 11-31.
-
(1975)
Circulation
, vol.52
, pp. 11-31
-
-
Pipberger, H.V.1
Arzbaecher, R.C.2
Berson, A.S.3
Briller, S.A.4
Brody, D.A.5
Flowers, N.C.6
Gieselowitz, D.B.7
Lepeschkin, E.8
Oliver, G.C.9
Schmitt, O.H.10
Spach, M.11
-
34
-
-
0036130222
-
The time relationships of the constituent components of the human electrocar-diogram
-
BURKE, M. J., #and NASOR, M., 2002, The time relationships of the constituent components of the human electrocar-diogram. Journal of Medical Engineering & Technology, 26, 1-6.
-
(2002)
Journal of Medical Engineering & Technology
, vol.26
, pp. 1-6
-
-
Burke, M.J.1
Nasor, M.2
-
35
-
-
0034889595
-
An accurate programmable ECG simulator
-
BURKE, M. J., and NASOR, M., 2001, An accurate programmable ECG simulator. Journal of Medical Engineering & Technology, 25, 97-102.
-
(2001)
Journal of Medical Engineering & Technology
, vol.25
, pp. 97-102
-
-
Burke, M.J.1
Nasor, M.2
|