메뉴 건너뛰기




Volumn 24, Issue 5, 2003, Pages 485-488

Parathyroid scintigraphy with 99mtc sestamibi

Author keywords

[No Author keywords available]

Indexed keywords

DIAGNOSTIC AGENT; METHOXY ISOBUTYL ISONITRILE TECHNETIUM TC 99M; RADIOPHARMACEUTICAL AGENT;

EID: 1542705893     PISSN: 01433636     EISSN: 14735628     Source Type: Journal    
DOI: 10.1097/00006231-200305000-00001     Document Type: Editorial
Times cited : (3)

References (42)
  • 2
    • 0026582792 scopus 로고
    • Parathyroid imaging with technetium-99m sestamibi: preoperative localisation and tissue uptake studies.
    • O’Doherty MJ, Kettle AG, Wells CP, Collins REC, Coakley AJ. Parathyroid imaging with technetium-99m sestamibi: preoperative localisation and tissue uptake studies. J Nucl Med 1992; 33: 313-318.
    • (1992) J Nucl Med , vol.33 , pp. 313-318
    • ODoherty, M.J.1    Kettle, A.G.2    Wells, C.P.3    Collins, R.4    Coakley, A.J.5
  • 3
    • 0026674754 scopus 로고
    • Detection and localisation of parathyroid adenomas in patients with hyperparathyroidism using a single radionuclide imaging procedure with technetium-99m-sestamibi (double-phase study).
    • Taillefer R, Boucher Y, Potvin C, Lambert R. Detection and localisation of parathyroid adenomas in patients with hyperparathyroidism using a single radionuclide imaging procedure with technetium-99m-sestamibi (double-phase study). J Nucl Med 1992; 33: 1801-1807.
    • (1992) J Nucl Med , vol.33 , pp. 1801-1807
    • Taillefer, R.1    Boucher, Y.2    Potvin, C.3    Lambert, R.4
  • 4
    • 0028297991 scopus 로고
    • Preoperative imaging of abnormal parathyroid glands in patients with hyperparathyroid disease using combination Tc-99m-pertechnetate and Tc-99m-sestamibi radionuclide scans.
    • Wei JP, Burke GJ, Mansberger AR. Preoperative imaging of abnormal parathyroid glands in patients with hyperparathyroid disease using combination Tc-99m-pertechnetate and Tc-99m-sestamibi radionuclide scans. Ann Surg 1994; 219: 568-573.
    • (1994) Ann Surg , vol.219 , pp. 568-573
    • Wei, J.P.1    Burke, G.J.2    Mansberger, A.R.3
  • 5
    • 0028833379 scopus 로고
    • Primary hyperparathyroidism: is technetium 99m-sestamibiiodine-123 subtraction scanning the best procedure to locate enlarged glands before surgery?
    • Hindié E, Melliere D, Simon D, Perlemuter L, Galle R. Primary hyperparathyroidism: is technetium 99m-sestamibi/iodine-123 subtraction scanning the best procedure to locate enlarged glands before surgery? J Clin Endocrinol Metab 1995; 80: 302-307.
    • (1995) J Clin Endocrinol Metab , vol.80 , pp. 302-307
    • Hindie, E.1    Melliere, D.2    Simon, D.3    Perlemuter, L.4    Galle, R.5
  • 6
    • 0030066339 scopus 로고    scopus 로고
    • The accuracy of parathyroid gland localisation in primary hyperparathyroidism using sestamibi radionuclide imaging.
    • Johnston LB, Carroll MJ, Britton KE, et al. The accuracy of parathyroid gland localisation in primary hyperparathyroidism using sestamibi radionuclide imaging. J Clin Endocrinol Metab 1996; 81: 346-352.
    • (1996) J Clin Endocrinol Metab , vol.81 , pp. 346-352
    • Johnston, L.B.1    Carroll, M.J.2    Britton, K.E.3
  • 7
    • 0034089663 scopus 로고    scopus 로고
    • Parathyroid imaging with pertechnetate plus perchlorateMIBI subtraction scintigraphy. A fast and effective technique.
    • Rubello D, Saladini G, Casara D, et al. Parathyroid imaging with pertechnetate plus perchlorate/MIBI subtraction scintigraphy. A fast and effective technique. Clin Nucl Med 2000; 25: 527-531.
    • (2000) Clin Nucl Med , vol.25 , pp. 527-531
    • Rubello, D.1    Saladini, G.2    Casara, D.3
  • 8
    • 0030998640 scopus 로고    scopus 로고
    • Localisation of ectopic parathyroid glands using technetium-99m sestamibi imaging: comparison with magnetic resonance and computed tomographic imaging.
    • Ishibashi M, Nishida H, Hiromatsu Y, Kojima K, Uchida M, Hayabuchi N. Localisation of ectopic parathyroid glands using technetium-99m sestamibi imaging: comparison with magnetic resonance and computed tomographic imaging. Eur J Nucl Med 1997; 24: 197-201.
    • (1997) Eur J Nucl Med , vol.24 , pp. 197-201
    • Ishibashi, M.1    Nishida, H.2    Hiromatsu, Y.3    Kojima, K.4    Uchida, M.5    Hayabuchi, N.6
  • 9
    • 12644310325 scopus 로고    scopus 로고
    • Efficacy of preoperative diagnostic imaging localisation of technetium 99m-sestamibi scintigraphy in hyperparathyroidism.
    • Caixàs A, Bernà L, Hernández A, et al. Efficacy of preoperative diagnostic imaging localisation of technetium 99m-sestamibi scintigraphy in hyperparathyroidism. Surgery 1997; 121: 535-541.
    • (1997) Surgery , vol.121 , pp. 535-541
    • Caixas, A.1    Berna, L.2    Hernandez, A.3
  • 10
    • 0031930383 scopus 로고    scopus 로고
    • Estudio del hiperparatiroidismo primario mediante gammagrafia en dos fases con 99mTc-MIBI: deteccion preoperatoria de las glandulas patologicas.
    • Blanco I, Carril JM, Banzo I, et al. Estudio del hiperparatiroidismo primario mediante gammagrafía en dos fases con 99mTc-MIBI: detección preoperatoria de las glándulas patológicas. Rev Esp Med Nucl 1998; 17: 8-14.
    • (1998) Rev Esp Med Nucl , vol.17 , pp. 8-14
    • Blanco, I.1    Carril, J.M.2    Banzo, I.3
  • 11
    • 0030119484 scopus 로고    scopus 로고
    • Technetium-99m-methoxyisobutylisonitrile in localisation of ectopic parathyroid adenoma.
    • Bernà L, Caixàs A, Piera J, et al. Technetium-99m-methoxyisobutylisonitrile in localisation of ectopic parathyroid adenoma. J Nucl Med 1996; 37: 631-633.
    • (1996) J Nucl Med , vol.37 , pp. 631-633
    • Berna, L.1    Caixas, A.2    Piera, J.3
  • 12
    • 85026175870 scopus 로고
    • 99mTc-sestamibi parathyroid scintigraphy. In: Freeman L, ed. Nuclear medicine annual 1995.
    • 99mTc-sestamibi parathyroid scintigraphy. In: Freeman L, ed. Nuclear medicine annual 1995. New York: Raven Press, 1995: 51-79.
    • (1995) New York: Raven Press , vol.51 , pp. 79
    • Taillefer, R.1
  • 13
    • 0030953069 scopus 로고    scopus 로고
    • Comparison of parathyroid imaging with technetium-99m-pertechnetatesestamibi subtraction, dual-phase technetium-99m-sestamibi and technetium-99m-sestamibi SPECT.
    • Chen CC, Holder LE, Scovill WA, Tehan AM, Gann DS. Comparison of parathyroid imaging with technetium-99m-pertechnetate/sestamibi subtraction, dual-phase technetium-99m-sestamibi and technetium-99m-sestamibi SPECT. J Nucl Med 1997; 38: 834-839.
    • (1997) J Nucl Med , vol.38 , pp. 834-839
    • Chen, C.C.1    Holder, L.E.2    Scovill, W.A.3    Tehan, A.M.4    Gann, D.S.5
  • 15
    • 0041926001 scopus 로고    scopus 로고
    • CK, Lim J, Lorberboym, et al. Parathyroid scintigraphy: dual (I-123 and Tc-99m MIBI) vs single (early and delayed MIBI) isotope imaging.
    • Kim CK, Lim J, Lorberboym, et al. Parathyroid scintigraphy: dual (I-123 and Tc-99m MIBI) vs single (early and delayed MIBI) isotope imaging. J Nucl Med 1996; 37(suppl): 16P.
    • (1996) J Nucl Med , vol.37
  • 18
    • 0036449478 scopus 로고    scopus 로고
    • Parathyroid 99mTc-sestamibi scintigraphy: dual-tracer subtraction is superior to double-phase washout.
    • 99mTc-sestamibi scintigraphy: dual-tracer subtraction is superior to double-phase washout. Eur J Nucl Med 2002; 29: 1566-1570.
    • (2002) Eur J Nucl Med , vol.29 , pp. 1566-1570
    • Leslie, W.D.1    Dupont, J.O.2    Bybel, B.3    Riese, K.T.4
  • 19
    • 0031032716 scopus 로고    scopus 로고
    • Localisation of a parathyroid adenoma by the addition of pinhole imaging to Tc-99m sestamibi dual-phase scintigraphy. Report of a case and review of experience.
    • Kipper MS, LaBarbera JJ, Krohn LD, Marcou LM. Localisation of a parathyroid adenoma by the addition of pinhole imaging to Tc-99m sestamibi dual-phase scintigraphy. Report of a case and review of experience. Clin Nucl Med 1997; 22: 73-75.
    • (1997) Clin Nucl Med , vol.22 , pp. 73-75
    • Kipper, M.S.1    LaBarbera, J.J.2    Krohn, L.D.3    Marcou, L.M.4
  • 20
    • 0036126461 scopus 로고    scopus 로고
    • Presurgical localisation of abnormal parathyroid glands using a single injection of Tc-99m-sestamibi: comparison of high-resolution parallel-hole and pinhole collimator, and interobserver and intraobserver variation.
    • Arveschoug AK, Bestelsen H, Vammen B. Presurgical localisation of abnormal parathyroid glands using a single injection of Tc-99m-sestamibi: comparison of high-resolution parallel-hole and pinhole collimator, and interobserver and intraobserver variation. Clin Nucl Med 2002; 27: 249-254.
    • (2002) Clin Nucl Med , vol.27 , pp. 249-254
    • Arveschoug, A.K.1    Bestelsen, H.2    Vammen, B.3
  • 21
    • 0029830663 scopus 로고    scopus 로고
    • Parathyroid adenomas: accurate detection and localisation with Tc-99m sestamibi SPECT.
    • Perez-Monte JE, Brown ML, Shah AN, et al. Parathyroid adenomas: accurate detection and localisation with Tc-99m sestamibi SPECT. Radiology 1996; 201: 85-91.
    • (1996) Radiology , vol.201 , pp. 85-91
    • Perez-Monte, J.E.1    Brown, M.L.2    Shah, A.N.3
  • 22
    • 0030138842 scopus 로고    scopus 로고
    • Efficient parathyroidectomy guided by SPECT-MIBI and hormonal measurements.
    • Sfakianakis GN, Irvin III GL, Foss J, et al. Efficient parathyroidectomy guided by SPECT-MIBI and hormonal measurements. J Nucl Med 1996; 37: 798-804.
    • (1996) J Nucl Med , vol.37 , pp. 798-804
    • Sfakianakis, G.N.1    Irvin, G.L.2    Foss, J.3
  • 23
    • 0029864540 scopus 로고    scopus 로고
    • Advantages of SPECT in technetium-99m-sestamibi parathyroid scintigraphy.
    • Billotey C, Sarfati E, Aurengo A, et al. Advantages of SPECT in technetium-99m-sestamibi parathyroid scintigraphy. J Nucl Med 1996; 37: 1773-1778.
    • (1996) J Nucl Med , vol.37 , pp. 1773-1778
    • Billotey, C.1    Sarfati, E.2    Aurengo, A.3
  • 24
    • 84876099849 scopus 로고    scopus 로고
    • SPECT vs planar imaging for preoperative parathyroid lesion localisation.
    • Tomas MB, Torres MA, Bhuiya TA, et al. SPECT vs planar imaging for preoperative parathyroid lesion localisation. J Nucl Med 1996; 37(suppl): 242P-243P.
    • (1996) J Nucl Med , vol.37
    • Tomas, M.B.1    Torres, M.A.2    Bhuiya, T.A.3
  • 26
    • 84876147453 scopus 로고    scopus 로고
    • Dual-phase (DP) SPECT has higher sensitivity and accuracy and similar specificity compared with DP planar Tc-99m-MIBI imaging in the detection of parathyroid adenoma (PA).
    • Juweid ME, Menda Y, Howe J, Graham MM. Dual-phase (DP) SPECT has higher sensitivity and accuracy and similar specificity compared with DP planar Tc-99m-MIBI imaging in the detection of parathyroid adenoma (PA). Eur J Nucl Med 2002; 29: S170.
    • (2002) Eur J Nucl Med , vol.29
    • Juweid, M.E.1    Menda, Y.2    Howe, J.3    Graham, M.M.4
  • 27
    • 0029148719 scopus 로고
    • Tc-99m tetrofosmin. A new diagnostic tracer for parathyroid imaging.
    • Ishibashi M, Nishida H, Kumabe T, et al. Tc-99m tetrofosmin. A new diagnostic tracer for parathyroid imaging. Clin Nucl Med 1995; 20: 902-905.
    • (1995) Clin Nucl Med , vol.20 , pp. 902-905
    • Ishibashi, M.1    Nishida, H.2    Kumabe, T.3
  • 29
    • 0031603978 scopus 로고    scopus 로고
    • Utilizacion de la gammagrafia con 99mTc-tetrofosmin en el diagnostico de pacientes con hiperparatiroidismo.
    • 99mTc-tetrofosmin en el diagnóstico de pacientes con hiperparatiroidismo. Rev Esp Med Nucl 1998; 17: 94-101.
    • (1998) Rev Esp Med Nucl , vol.17 , pp. 94-101
    • Vallejos, V.1    Martin-Comin, J.2    Mora, J.3
  • 30
    • 0030970528 scopus 로고    scopus 로고
    • Technetium-99m-tetrofosmin for parathyroid scintigraphy: a comparison with sestamibi.
    • Fjeld JG, Erichsen K, Pfeffer PF, Clausen OPF, Rootwelt K. Technetium-99m-tetrofosmin for parathyroid scintigraphy: a comparison with sestamibi. J Nucl Med 1997; 38: 831-834.
    • (1997) J Nucl Med , vol.38 , pp. 831-834
    • Fjeld, J.G.1    Erichsen, K.2    Pfeffer, P.F.3    Clausen, O.4    Rootwelt, K.5
  • 31
    • 0029974350 scopus 로고    scopus 로고
    • Parathyroid scintigraphy: comparison of technetium-99 methoxyisobutylisonitrile and technetium-99m tetrofosmin studies.
    • Aigner RM, Fueger GF, Nicoletti R. Parathyroid scintigraphy: comparison of technetium-99 methoxyisobutylisonitrile and technetium-99m tetrofosmin studies. Eur J Nucl Med 1996; 23: 693-696.
    • (1996) Eur J Nucl Med , vol.23 , pp. 693-696
    • Aigner, R.M.1    Fueger, G.F.2    Nicoletti, R.3
  • 32
    • 0033790154 scopus 로고    scopus 로고
    • Minimally invasive parathyroid surgery.
    • Howe JR. Minimally invasive parathyroid surgery. Surg Clin North Am 2000; 80: 1399-1426.
    • (2000) Surg Clin North Am , vol.80 , pp. 1399-1426
    • Howe, J.R.1
  • 33
    • 0033637365 scopus 로고    scopus 로고
    • Unilateral surgery for primary hyperparathyroidism on the basis of Tc-99m sestamibi and iodine-123 subtraction scanning.
    • Hindie E, Melliere D, Jeanguillaume C, Urena P, deLabriolle-Vaylet C, Perlemuter L. Unilateral surgery for primary hyperparathyroidism on the basis of Tc-99m sestamibi and iodine-123 subtraction scanning. Arch Surg 2000; 135: 1461-1468.
    • (2000) Arch Surg , vol.135 , pp. 1461-1468
    • Hindie, E.1    Melliere, D.2    Jeanguillaume, C.3    Urena, P.4    deLabriolle-Vaylet C, Perlemuter, L.5
  • 34
    • 0036960329 scopus 로고    scopus 로고
    • Parathyroid surgery: separating promise from reality.
    • Perrier ND, Ituarte PH, Morita E, et al. Parathyroid surgery: separating promise from reality. J Clin Endocrinol Metab 2002; 87: 1024-1029.
    • (2002) J Clin Endocrinol Metab , vol.87 , pp. 1024-1029
    • Perrier, N.D.1    Ituarte, P.H.2    Morita, E.3
  • 35
    • 0036688483 scopus 로고    scopus 로고
    • Will directed parathyroidectomy utilizing the gamma probe or intraoperative parathyroid hormone assay replace bilateral cervical exploration as the preferred operation for primary hyperparathyroidism?
    • Burkey SH, Van Heerden JA, Farley DR, Thompson GB, Grant CS, Curlee KJ. Will directed parathyroidectomy utilizing the gamma probe or intraoperative parathyroid hormone assay replace bilateral cervical exploration as the preferred operation for primary hyperparathyroidism? World J Surg 2002; 26: 914-920.
    • (2002) World J Surg , vol.26 , pp. 914-920
    • Burkey, S.H.1    Van Heerden, J.A.2    Farley, D.R.3    Thompson, G.B.4    Grant, C.S.5    Curlee, K.J.6
  • 36
    • 0036690313 scopus 로고    scopus 로고
    • New point-of-care: intraoperative parathyroid hormone assay for intraoperative guidance in parathyroidectomy.
    • Carneiro DM, Irvin III GL. New point-of-care: intraoperative parathyroid hormone assay for intraoperative guidance in parathyroidectomy. World J Surg 2002; 26: 1074-1077.
    • (2002) World J Surg , vol.26 , pp. 1074-1077
    • Carneiro, D.M.1    Irvin, G.L.2
  • 37
    • 0036324525 scopus 로고    scopus 로고
    • Modern parathyroid surgery: a cost-benefit analysis of localizing strategies.
    • Fahy BN, Bold RJ, Beckett L, Schneider PD. Modern parathyroid surgery: a cost-benefit analysis of localizing strategies. Arch Surg 2002; 137: 917-923.
    • (2002) Arch Surg , vol.137 , pp. 917-923
    • Fahy, B.N.1    Bold, R.J.2    Beckett, L.3    Schneider, P.D.4
  • 38
    • 0035666728 scopus 로고    scopus 로고
    • Intraoperative parathyroid hormone monitoring fails to detect double parathyroid adenomas: a 2-institution experience.
    • Gauger PS, Agarwal G, England BG, et al. Intraoperative parathyroid hormone monitoring fails to detect double parathyroid adenomas: a 2-institution experience. Surgery 2001; 130: 1005-1010.
    • (2001) Surgery , vol.130 , pp. 1005-1010
    • Gauger, P.S.1    Agarwal, G.2    England, B.G.3
  • 39
    • 0036323599 scopus 로고    scopus 로고
    • 3rd WB, Kim CK, Haber RS, Lopchinsky RA. Radioguidance is not necessary during parathyroidectomy.
    • Inabnet 3rd WB, Kim CK, Haber RS, Lopchinsky RA. Radioguidance is not necessary during parathyroidectomy. Arch Surg 2002; 137: 967-970.
    • (2002) Arch Surg , vol.137 , pp. 967-970
  • 40
    • 0036688483 scopus 로고    scopus 로고
    • Will directed parathyroidectomy utilizing the gamma probe or intraoperative parathyroid hormone assay replace bilateral cervical exploration as the preferred operation for primary hyperparathyroidism?
    • Burkey SH, Van Heerden JA, Farley DR, Thompson GB, Grant CS, Curlee KJ. Will directed parathyroidectomy utilizing the gamma probe or intraoperative parathyroid hormone assay replace bilateral cervical exploration as the preferred operation for primary hyperparathyroidism? World J Surg 2002; 26: 914-920.
    • (2002) World J Surg , vol.26 , pp. 914-920
    • Burkey, S.H.1    Van Heerden, J.A.2    Farley, D.R.3    Thompson, G.B.4    Grant, C.S.5    Curlee, K.J.6
  • 41
    • 0033044922 scopus 로고    scopus 로고
    • Reoperative parathyroid surgery in the era of sestamibi scanning and intraoperative parathyroid hormone monitoring.
    • Thompson GB, Grant CS, Perrier ND, et al. Reoperative parathyroid surgery in the era of sestamibi scanning and intraoperative parathyroid hormone monitoring. Arch Surg 1999; 134: 699-705.
    • (1999) Arch Surg , vol.134 , pp. 699-705
    • Thompson, G.B.1    Grant, C.S.2    Perrier, N.D.3
  • 42
    • 0036183794 scopus 로고    scopus 로고
    • Prospective evaluation of delayed technetium-99m sestamibi SPECT scintigraphy for preoperative localisation of primary hyperparathyroidism.
    • Civelek AC, Ozalp E, Donovan P, Udelsman R. Prospective evaluation of delayed technetium-99m sestamibi SPECT scintigraphy for preoperative localisation of primary hyperparathyroidism. Surgery 2002; 131: 149-157.
    • (2002) Surgery , vol.131 , pp. 149-157
    • Civelek, A.C.1    Ozalp, E.2    Donovan, P.3    Udelsman, R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.