Volumn 30, Issue 2, 1996, Pages 145-150

Polyurethane versus silicone for endoprosthetic replacement of the metacarpophalangeal joints in rheumatoid arthritis

Author keywords

Endoprosthesis; Implant surgery; Polyurethane

Indexed keywords

POLYURETHAN; SILICONE;

EID: 1542635193     PISSN: 02844311     EISSN: None     Source Type: Journal    
DOI: 10.3109/02844319609056397     Document Type: Article
Times cited : (20)

References (32)
  • 1
    • 0025365820 scopus 로고
    • Schultz metacarpophalangeal arthroplasty: A long term follow-up study
    • Adams BD, Blair WF, Shurr DG, Schultz metacarpophalangeal arthroplasty: A long term follow-up study. J Hand Surg 1990; 15A: 641-645.
    • (1990) J Hand Surg , vol.15 A , pp. 641-645
    • Adams, B.D.1    Blair, W.F.2    Shurr, D.G.3
  • 3
    • 0022614097 scopus 로고
    • Silicone-rubber implant arthroplasty of the metacarpophalangeal joints for rheumatoid arthritis
    • Bieber EJ, Weiland AJ, Volenec-Dowling S. Silicone-rubber implant arthroplasty of the metacarpophalangeal joints for rheumatoid arthritis. J Bone Joint Surg 1986; 68A: 206-209.
    • (1986) J Bone Joint Surg , vol.68 A , pp. 206-209
    • Bieber, E.J.1    Weiland, A.J.2    Volenec-Dowling, S.3
  • 5
    • 0022649013 scopus 로고
    • Failure of silicone rubber wrist arthroplasty in rheumatoid arthritis
    • Brase D, Millender L. Failure of silicone rubber wrist arthroplasty in rheumatoid arthritis. J Hand Surg 1986; 11A: 175-183.
    • (1986) J Hand Surg , vol.11 A , pp. 175-183
    • Brase, D.1    Millender, L.2
  • 6
    • 0023637341 scopus 로고
    • High resolution CT of the wrist: Initial experience with scaphoid disorders and surgical fusions
    • Bush CH, Gillespy IT, Dell PC. High resolution CT of the wrist: initial experience with scaphoid disorders and surgical fusions. AJR 1987; 149: 757-760.
    • (1987) AJR , vol.149 , pp. 757-760
    • Bush, C.H.1    Gillespy, I.T.2    Dell, P.C.3
  • 7
    • 0023030680 scopus 로고
    • Silicone rubber carpal implants: A study of the incidence of late osseous complications
    • Carter P, Benton L, Dysert P. Silicone rubber carpal implants: A study of the incidence of late osseous complications. J Hand Surg 1986; 11A: 639-644.
    • (1986) J Hand Surg , vol.11 A , pp. 639-644
    • Carter, P.1    Benton, L.2    Dysert, P.3
  • 9
    • 0018135233 scopus 로고
    • An evaluation of a polyurethane for use as a medical grade plastic
    • Darby T, Johnson H, Northup S. An evaluation of a polyurethane for use as a medical grade plastic. Toxicol Appl Pharmacol 1978; 46: 449-453.
    • (1978) Toxicol Appl Pharmacol , vol.46 , pp. 449-453
    • Darby, T.1    Johnson, H.2    Northup, S.3
  • 11
    • 84907035369 scopus 로고
    • Perichondrial arthroplasty: A clinical study in twenty-six patients
    • Engkvist O, Johansson SH. Perichondrial arthroplasty: A clinical study in twenty-six patients. Scand J Plast Reconstr Surg 1980; 14: 71-87.
    • (1980) Scand J Plast Reconstr Surg , vol.14 , pp. 71-87
    • Engkvist, O.1    Johansson, S.H.2
  • 13
    • 0023288602 scopus 로고
    • Angular dependent ESCA and infrared studies of segmented polyurethanes
    • Grobe G, Gardella J, Hopson W, McKenna W, Eyring E. Angular dependent ESCA and infrared studies of segmented polyurethanes. J Biomed Mat Res 1987; 21: 211-229.
    • (1987) J Biomed Mat Res , vol.21 , pp. 211-229
    • Grobe, G.1    Gardella, J.2    Hopson, W.3    McKenna, W.4    Eyring, E.5
  • 14
    • 0016825490 scopus 로고
    • Metacarpophalangeal joint implants. I. Roentgenographic study of the silastic finger joint implant. Swanson design
    • Hagert C, Eiken O, Ohlsson N, Aschan W, Movin A. Metacarpophalangeal joint implants. I. Roentgenographic study of the silastic finger joint implant. Swanson design. Scand J Plast Reconstr Surg 1975; 9: 147-157.
    • (1975) Scand J Plast Reconstr Surg , vol.9 , pp. 147-157
    • Hagert, C.1    Eiken, O.2    Ohlsson, N.3    Aschan, W.4    Movin, A.5
  • 15
    • 0027772410 scopus 로고
    • Metacarpophalangeal joint arthroplasty based on the osseointegration concept
    • Lundborg G, Branemark P-I, Carlsson I. Metacarpophalangeal joint arthroplasty based on the osseointegration concept. J Hand Surg 1993; 18B: 693-703.
    • (1993) J Hand Surg , vol.18 B , pp. 693-703
    • Lundborg, G.1    Branemark, P.-I.2    Carlsson, I.3
  • 16
    • 0023306143 scopus 로고
    • Physicochemical characterization of a hydrophilic microporous polyurethane vascular graft
    • Martz H, Beaudoin G, Paynter R, King M, Marceau D, Guidoin R. Physicochemical characterization of a hydrophilic microporous polyurethane vascular graft. J Biomed Mat Res 1987; 21: 399-412.
    • (1987) J Biomed Mat Res , vol.21 , pp. 399-412
    • Martz, H.1    Beaudoin, G.2    Paynter, R.3    King, M.4    Marceau, D.5    Guidoin, R.6
  • 17
    • 0021503829 scopus 로고
    • Determination of extractable methylene dianiline in thermoplastic polyurethanes by HPLC
    • Mazzu A, Smith C. Determination of extractable methylene dianiline in thermoplastic polyurethanes by HPLC. J Biomed Mat Res 1984; 18: 961-968.
    • (1984) J Biomed Mat Res , vol.18 , pp. 961-968
    • Mazzu, A.1    Smith, C.2
  • 18
    • 0016200988 scopus 로고
    • An industrial outbreak of toxic hepatitis due to methylene-dianiline
    • McGill D, Motto J. An industrial outbreak of toxic hepatitis due to methylene-dianiline. N Engl J Med 1974; 291: 278-282.
    • (1974) N Engl J Med , vol.291 , pp. 278-282
    • McGill, D.1    Motto, J.2
  • 19
    • 0023740436 scopus 로고
    • Polyurethane implants: A 6-year review of 416 patients
    • Melmed E. Polyurethane implants: A 6-year review of 416 patients. Plast Reconstr Surg 1987; 82: 285-290.
    • (1987) Plast Reconstr Surg , vol.82 , pp. 285-290
    • Melmed, E.1
  • 20
    • 0020608509 scopus 로고
    • Long-term silicone implant arthroplasty
    • Nalbandian R, Swanson A, Maupin B. Long-term silicone implant arthroplasty. JAMA 1983; 250: 1195-1198.
    • (1983) JAMA , vol.250 , pp. 1195-1198
    • Nalbandian, R.1    Swanson, A.2    Maupin, B.3
  • 21
    • 0023915603 scopus 로고
    • Axillary lymphadenopathy 17 years after digital silicone implants; study with x-ray microanalysis
    • Paplamus S, Payne C. Axillary lymphadenopathy 17 years after digital silicone implants; study with x-ray microanalysis. J Hand Surg 1988; 13A: 411.
    • (1988) J Hand Surg , vol.13 A , pp. 411
    • Paplamus, S.1    Payne, C.2
  • 24
    • 0023325618 scopus 로고
    • Poly(ether) urethane reactivity with metal-ion in calcification and environmental stress cracking
    • Randall J. Poly(ether) urethane reactivity with metal-ion in calcification and environmental stress cracking. J Biomat Appl 1987; 1: 449.
    • (1987) J Biomat Appl , vol.1 , pp. 449
    • Randall, J.1
  • 26
    • 0024238299 scopus 로고
    • Silastic replacement of the trapezium for arthrosis - A twelve year follow-up study
    • Sollerman C, Herrlin K, Abrahamsson S-O, Lindholm A. Silastic replacement of the trapezium for arthrosis - A twelve year follow-up study. J Hand Surg 1988; 13B: 426-429.
    • (1988) J Hand Surg , vol.13 B , pp. 426-429
    • Sollerman, C.1    Herrlin, K.2    Abrahamsson, S.-O.3    Lindholm, A.4
  • 28
    • 0015326061 scopus 로고
    • Flexible implant arthroplasty for arthritic finger joints: Rationale, technique and results of treatment
    • Swanson AB. Flexible implant arthroplasty for arthritic finger joints: Rationale, technique and results of treatment. J Bone Joint Surg 1972; 54A: 435-455.
    • (1972) J Bone Joint Surg , vol.54 A , pp. 435-455
    • Swanson, A.B.1
  • 29
    • 0020916409 scopus 로고
    • Synthetic polymers in artificial hearts: A progress report
    • Szycher M, Poirier V. Synthetic polymers in artificial hearts: A progress report. Ind Eng Chem Prod Res Dev 1983; 22: 588-593.
    • (1983) Ind Eng Chem Prod Res Dev , vol.22 , pp. 588-593
    • Szycher, M.1    Poirier, V.2
  • 30
    • 0024516277 scopus 로고
    • The metacarpophalangeal volar plate arthroplasty
    • Tupper JW. The metacarpophalangeal volar plate arthroplasty. J Hand Surg 1989; 14A: 371-375.
    • (1989) J Hand Surg , vol.14 A , pp. 371-375
    • Tupper, J.W.1
  • 31
    • 0024524972 scopus 로고
    • Vainio arthoplasty of the metacarpophalangeal joints in rheumatoid arthritis
    • Vainio K. Vainio arthoplasty of the metacarpophalangeal joints in rheumatoid arthritis. J Hand Surg 1989; 14A: 367-368.
    • (1989) J Hand Surg , vol.14 A , pp. 367-368
    • Vainio, K.1