메뉴 건너뛰기




Volumn 25, Issue 3, 2004, Pages 371-375

The Silzone effect: How to reconcile contradictory reports?

Author keywords

Paravalvular leak; Silzone heart valve; St. Jude Medical heart valve; Thromboembolism

Indexed keywords

ARTICLE; CLINICAL FEATURE; CLINICAL TRIAL; COMPARATIVE STUDY; ENDOCARDITIS; HEART VALVE PROSTHESIS; HUMAN; INCIDENCE; PRIORITY JOURNAL; SAINT JUDE HEART VALVE PROSTHESIS; THROMBOEMBOLISM;

EID: 1542613961     PISSN: 10107940     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ejcts.2003.12.014     Document Type: Article
Times cited : (8)

References (25)
  • 2
    • 0000581752 scopus 로고    scopus 로고
    • Unexpectedly high incidence of embolic events with the St Jude Silzone valve
    • Ionescu A., Fraser A.G., Butchart E.G. Unexpectedly high incidence of embolic events with the St Jude Silzone valve. Eur Heart J. 20:1999;558.
    • (1999) Eur Heart J , vol.20 , pp. 558
    • Ionescu, A.1    Fraser, A.G.2    Butchart, E.G.3
  • 3
    • 0001404998 scopus 로고    scopus 로고
    • High incidence of embolism after St Jude Silzone prosthetic valve implantation
    • Ionescu A.A., Fraser A.G., Butchart E.G. High incidence of embolism after St Jude Silzone prosthetic valve implantation. Circulation. 100:1999;I-524.
    • (1999) Circulation , vol.100 , pp. 524
    • Ionescu, A.A.1    Fraser, A.G.2    Butchart, E.G.3
  • 4
    • 0035514649 scopus 로고    scopus 로고
    • Silzone coating and paravalvular leak: An independent, randomized study
    • Discussion pp. 715-716
    • Herijgers P., Herregods M.C., Vandeplas A., Meyns B., Flameng W. Silzone coating and paravalvular leak: an independent, randomized study. J Heart Valve Dis. 10:(6):2001;712-715. Discussion pp. 715-716.
    • (2001) J Heart Valve Dis , vol.10 , Issue.6 , pp. 712-715
    • Herijgers, P.1    Herregods, M.C.2    Vandeplas, A.3    Meyns, B.4    Flameng, W.5
  • 5
    • 0141836992 scopus 로고    scopus 로고
    • Thrombogenicity and reoperation of the St. Jude Silzone Valve: A comparison with the conventional St. Jude Valve
    • Stalenhoef J.E., Mellema E.C., Veeger N.J., Ebels T. Thrombogenicity and reoperation of the St. Jude Silzone Valve: a comparison with the conventional St. Jude Valve. J Heart Valve Dis. 12:(5):2003;635-639.
    • (2003) J Heart Valve Dis , vol.12 , Issue.5 , pp. 635-639
    • Stalenhoef, J.E.1    Mellema, E.C.2    Veeger, N.J.3    Ebels, T.4
  • 6
    • 0035106239 scopus 로고    scopus 로고
    • Thrombogenicity of the St. Jude medical prosthesis with and without silzone-coated sewing cuffs
    • Horstkotte D., Bergemann R. Thrombogenicity of the St. Jude medical prosthesis with and without silzone-coated sewing cuffs. Ann Thorac Surg. 71:(3):2001;1065.
    • (2001) Ann Thorac Surg , vol.71 , Issue.3 , pp. 1065
    • Horstkotte, D.1    Bergemann, R.2
  • 7
    • 1642633627 scopus 로고    scopus 로고
    • First clinical experience with a mechanical valve with silver coating
    • Discussion pp. 129-130
    • Brutel de la Riviere A., Dossche K.M., Birnbaum D.E., Hacker R. First clinical experience with a mechanical valve with silver coating. J Heart Valve Dis. 9:(1):2000;123-129. Discussion pp. 129-130.
    • (2000) J Heart Valve Dis , vol.9 , Issue.1 , pp. 123-129
    • Brutel De La Riviere, A.1    Dossche, K.M.2    Birnbaum, D.E.3    Hacker, R.4
  • 9
    • 0034747352 scopus 로고    scopus 로고
    • Silzone-coated St. Jude medical valve: A safe valve
    • Houel R., Kirsch M., Hillion M.L., Loisance D. Silzone-coated St. Jude medical valve: a safe valve. J Heart Valve Dis. 10:(6):2001;724-727.
    • (2001) J Heart Valve Dis , vol.10 , Issue.6 , pp. 724-727
    • Houel, R.1    Kirsch, M.2    Hillion, M.L.3    Loisance, D.4
  • 10
    • 0042328280 scopus 로고    scopus 로고
    • Incidence of embolism and paravalvar leak after St Jude Silzone valve implantation: Experience from the Cardiff Embolic Risk Factor Study
    • Ionescu A., Payne N., Fraser A.G., Giddings J., Grunkemeier G.L., Butchart E.G. Incidence of embolism and paravalvar leak after St Jude Silzone valve implantation: experience from the Cardiff Embolic Risk Factor Study. Heart. 89:(9):2003;1055-1061.
    • (2003) Heart , vol.89 , Issue.9 , pp. 1055-1061
    • Ionescu, A.1    Payne, N.2    Fraser, A.G.3    Giddings, J.4    Grunkemeier, G.L.5    Butchart, E.G.6
  • 12
    • 0032948422 scopus 로고    scopus 로고
    • Artificial Valve Endocarditis Reduction Trial (AVERT): Protocol of a multicenter randomized trial
    • Schaff H., Carrel T., Steckelberg J.M., Grunkemeier G.L., Holubkov R. Artificial Valve Endocarditis Reduction Trial (AVERT): protocol of a multicenter randomized trial. J Heart Valve Dis. 8:(2):1999;131-139.
    • (1999) J Heart Valve Dis , vol.8 , Issue.2 , pp. 131-139
    • Schaff, H.1    Carrel, T.2    Steckelberg, J.M.3    Grunkemeier, G.L.4    Holubkov, R.5
  • 13
    • 0031670540 scopus 로고    scopus 로고
    • Definitive cure of recurrent prosthetic endocarditis using silver-coated St. Jude Medical heart valves: A preliminary case report
    • Carrel T., Nguyen T., Kipfer B., Althaus U. Definitive cure of recurrent prosthetic endocarditis using silver-coated St. Jude Medical heart valves: a preliminary case report. J Heart Valve Dis. 7:(5):1998;531-533.
    • (1998) J Heart Valve Dis , vol.7 , Issue.5 , pp. 531-533
    • Carrel, T.1    Nguyen, T.2    Kipfer, B.3    Althaus, U.4
  • 14
    • 0033630092 scopus 로고    scopus 로고
    • Employment of St. Jude 'silzone' valve in the surgical treatment of early prosthetic valve endocarditis: A preliminary case report and review of the literature
    • Garcia Fuster R., Montero Argudo J.A., Gil Albarova O., Hornero Sos F., Canovas S., Dalmau Sorli M.J. Employment of St. Jude 'silzone' valve in the surgical treatment of early prosthetic valve endocarditis: a preliminary case report and review of the literature. Rev Esp Cardiol. 53:(1):2000;139-141.
    • (2000) Rev Esp Cardiol , vol.53 , Issue.1 , pp. 139-141
    • Garcia Fuster, R.1    Montero Argudo, J.A.2    Gil Albarova, O.3    Hornero Sos, F.4    Canovas, S.5    Dalmau Sorli, M.J.6
  • 15
    • 0033974986 scopus 로고    scopus 로고
    • Preliminary experience with Silzone-coated St. Jude medical valves in acute infective endocarditis
    • Bertrand S., Houel R., Vermes E., Soustelle C., Hillion M.L., Loisance D. Preliminary experience with Silzone-coated St. Jude medical valves in acute infective endocarditis. J Heart Valve Dis. 9:(1):2000;131-134.
    • (2000) J Heart Valve Dis , vol.9 , Issue.1 , pp. 131-134
    • Bertrand, S.1    Houel, R.2    Vermes, E.3    Soustelle, C.4    Hillion, M.L.5    Loisance, D.6
  • 17
    • 0035006437 scopus 로고    scopus 로고
    • Silver-coated prosthetic heart valve: A double-bladed weapon
    • Tozzi P., Al-Darweesh A., Vogt P., Stumpe F. Silver-coated prosthetic heart valve: a double-bladed weapon. Eur J Cardiothorac Surg. 19:(5):2001;729-731.
    • (2001) Eur J Cardiothorac Surg , vol.19 , Issue.5 , pp. 729-731
    • Tozzi, P.1    Al-Darweesh, A.2    Vogt, P.3    Stumpe, F.4
  • 18
    • 0036154518 scopus 로고    scopus 로고
    • Prosthetic valve endocarditis occurring on a silzone coated heart valve used as treatment for rheumatic mitral valve disease
    • Cooper M.H., Onsager D.R., Ende D., Chopra P.S. Prosthetic valve endocarditis occurring on a silzone coated heart valve used as treatment for rheumatic mitral valve disease. Eur J Cardiothorac Surg. 21:(1):2002;158-159.
    • (2002) Eur J Cardiothorac Surg , vol.21 , Issue.1 , pp. 158-159
    • Cooper, M.H.1    Onsager, D.R.2    Ende, D.3    Chopra, P.S.4
  • 19
    • 0036331985 scopus 로고    scopus 로고
    • Prosthetic heart valves with silver-coated sewing cuff fabric: Early morphological features in two patients
    • Butany J., Scully H.E., VanArsdell G., Leask R. Prosthetic heart valves with silver-coated sewing cuff fabric: early morphological features in two patients. Can J Cardiol. 18:(7):2002;733-738.
    • (2002) Can J Cardiol , vol.18 , Issue.7 , pp. 733-738
    • Butany, J.1    Scully, H.E.2    Vanarsdell, G.3    Leask, R.4
  • 21
    • 33845382806 scopus 로고
    • Nonparametric estimation from incomplete observations
    • Kaplan E.L., Meier P. Nonparametric estimation from incomplete observations. J Am Stat Assoc. 53:1958;457-481.
    • (1958) J Am Stat Assoc , vol.53 , pp. 457-481
    • Kaplan, E.L.1    Meier, P.2
  • 22
    • 0000166882 scopus 로고
    • Some simple approximate test for Poisson variates
    • Cox D.R. Some simple approximate test for Poisson variates. Biometrika. 40:1953;354-360.
    • (1953) Biometrika , vol.40 , pp. 354-360
    • Cox, D.R.1
  • 23
    • 0031961463 scopus 로고    scopus 로고
    • Clinical evaluation and analysis of heart valve substitutes
    • Grunkemeier G.L., Anderson W.N. Jr. Clinical evaluation and analysis of heart valve substitutes. J Heart Valve Dis. 7:1998;163-169.
    • (1998) J Heart Valve Dis , vol.7 , pp. 163-169
    • Grunkemeier, G.L.1    Anderson Jr., W.N.2
  • 24
    • 0006507249 scopus 로고
    • Division of Cardiovascular, Respiratory, and Neurological Devices, Center for Devices and Radiological Health, Food and Drug Administration. Draft Replacement Heart Valve Guidance, Version 4.1; 1994.
    • (1994) Draft Replacement Heart Valve Guidance, Version 4.1
  • 25
    • 0034109733 scopus 로고    scopus 로고
    • The Silzone dilemma - What did we learn?
    • Bodnar E. The Silzone dilemma - what did we learn? J Heart Valve Dis. 9:(2):2000;170-173.
    • (2000) J Heart Valve Dis , vol.9 , Issue.2 , pp. 170-173
    • Bodnar, E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.