메뉴 건너뛰기




Volumn 6, Issue 4, 2003, Pages 187-190

Scan mode performance of dual energy X-ray absorptiometry bone densitometer

Author keywords

Bone density; Scan

Indexed keywords

MINERAL;

EID: 1542606440     PISSN: None     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (1)

References (13)
  • 1
    • 0026034394 scopus 로고
    • Longitudinal precision of dual energy X-ray absorptiometry in a multicenter study
    • Nafarelin/Bone Study Group
    • Orwoll ES, Oviatt SK, Nafarelin/Bone Study Group. Longitudinal precision of dual energy X-ray absorptiometry in a multicenter study. J Bone Miner Res 1991;6:191-197.
    • (1991) J. Bone Miner Res. , vol.6 , pp. 191-197
    • Orwoll, E.S.1    Oviatt, S.K.2
  • 2
    • 0025303078 scopus 로고
    • Dual-energy X-ray absorptiometry for total-body and regional bone-mineral and soft-tissue composition
    • Mazess RB, Barden HS, Bisek JP, Hansen J. Dual-energy X-ray absorptiometry for total-body and regional bone-mineral and soft-tissue composition. Am J Clin Nutr 1990;51:1106-1112.
    • (1990) Am. J. Clin. Nutr. , vol.51 , pp. 1106-1112
    • Mazess, R.B.1    Barden, H.S.2    Bisek, J.P.3    Hansen, J.4
  • 3
    • 0026012481 scopus 로고
    • Precision and stability of dual-energy X-ray absorptiometry measurements
    • Johnson J, Dawson-Hughes B. Precision and stability of dual-energy X-ray absorptiometry measurements. Calcif Tissue Int 1991;49:174-178.
    • (1991) Calcif. Tissue Int. , vol.49 , pp. 174-178
    • Johnson, J.1    Dawson-Hughes, B.2
  • 4
    • 0024336819 scopus 로고
    • X-ray dual-photon absorptiometry: A new method for the measurement of bone density
    • Cullum ID, Ell PJ, Ryder JP. X-ray dual-photon absorptiometry: A new method for the measurement of bone density. Br J Radiol 1989;62:587-592.
    • (1989) Br. J. Radiol. , vol.62 , pp. 587-592
    • Cullum, I.D.1    Ell, P.J.2    Ryder, J.P.3
  • 5
    • 0026046427 scopus 로고
    • Comparative performance in vitro and in vivo of Lunar DPX and Hologic QDR-1000 dual energy X-ray absorptiometers
    • Laskey MA, Flaxman ME, Barber RW, et al. Comparative performance in vitro and in vivo of Lunar DPX and Hologic QDR-1000 dual energy X-ray absorptiometers. Br J Radiol 1991;64: 1023-1029.
    • (1991) Br. J. Radiol. , vol.64 , pp. 1023-1029
    • Laskey, M.A.1    Flaxman, M.E.2    Barber, R.W.3
  • 6
    • 0001584034 scopus 로고
    • Performance evaluation of a new bone densitometer: Hologic QDR-4500
    • Fuerst T, Gluer CC, Genant HK. Performance evaluation of a new bone densitometer: Hologic QDR-4500. J Bone Miner Res 1995;10 (Suppl):370.
    • (1995) J. Bone Miner. Res. , vol.10 , Issue.SUPPL. , pp. 370
    • Fuerst, T.1    Gluer, C.C.2    Genant, H.K.3
  • 7
    • 0034985938 scopus 로고    scopus 로고
    • Development of a phantom for morphometric X-ray absorptiometry
    • Rea JA, Blake GM, Fogelman I. Development of a phantom for morphometric X-ray absorptiometry. Br J Radiol 2001;74(880): 341-350.
    • (2001) Br. J. Radiol. , vol.74 , Issue.880 , pp. 341-350
    • Rea, J.A.1    Blake, G.M.2    Fogelman, I.3
  • 8
    • 0028956926 scopus 로고
    • Evaluation of dual-energy X-ray absorpiometry bone mineral measurement - Comparison of a single-beam and fan-beam design: The effect of osteophytic calification on spine bone mineral density
    • Franck H, Munz M, Scherrer M. Evaluation of dual-energy X-ray absorpiometry bone mineral measurement - comparison of a single-beam and fan-beam design: The effect of osteophytic calification on spine bone mineral density. Calcif Tissue Int 1995;56(3):192-195.
    • (1995) Calcif. Tissue Int. , vol.56 , Issue.3 , pp. 192-195
    • Franck, H.1    Munz, M.2    Scherrer, M.3
  • 9
    • 0028791592 scopus 로고
    • Hologic QDR 2000 whole-body scans: A comparison of three combination's of scan modes and analysis software
    • Spector E, LeBlanc A, Shackelford L. Hologic QDR 2000 whole-body scans: A comparison of three combination's of scan modes and analysis software. Osteoporosis Int 1995;5:440-445.
    • (1995) Osteoporosis Int. , vol.5 , pp. 440-445
    • Spector, E.1    LeBlanc, A.2    Shackelford, L.3
  • 12
    • 1542395511 scopus 로고
    • Clinical evaluation of a fourth generation fan beam DXA system
    • Baran D, Leahey D, Von Stetton E. Clinical evaluation of a fourth generation fan beam DXA system. J Bone Miner Res 1995;10 (Suppl):374.
    • (1995) J. Bone Miner. Res. , vol.10 , Issue.SUPPL. , pp. 374
    • Baran, D.1    Leahey, D.2    Von Stetton, E.3
  • 13
    • 1542605089 scopus 로고    scopus 로고
    • Hologic. Reference database and reports
    • Waltham
    • Hologic. Reference database and reports. QDR 4500 Operator's Manual. Waltham, 8.1-20.
    • QDR 4500 Operator's Manual , vol.8 , pp. 1-20


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.