1
-
-
0346450102
-
Image and sample geometry effects in SQUID magnetometers
-
Zieba A 1993 Image and sample geometry effects in SQUID magnetometers Rev. Sci. Instrum. 64 3357-74
-
(1993)
Rev. Sci. Instrum.
, vol.64
, pp. 3357-3374
-
-
Zieba, A.1
-
2
-
-
1542684304
-
Spatial Fourier transform method for evaluating SQUID gradiometers
-
Costa Ribeiro P, Bruno A C and Paulsen C C 1987 Spatial Fourier transform method for evaluating SQUID gradiometers Rev. Sci. Instrum. 58 (8) 1510-3
-
(1987)
Rev. Sci. Instrum.
, vol.58
, Issue.8
, pp. 1510-1513
-
-
Costa Ribeiro, P.1
Bruno, A.C.2
Paulsen, C.C.3
-
3
-
-
0020155059
-
Sample holder for measurement of small magnetic moments using SQUID magnetometers
-
Roy A, Buchanan D S and Ginsberg D M 1982 Sample holder for measurement of small magnetic moments using SQUID magnetometers Rev. Sci. Instrum. 53 (7) 1053-7
-
(1982)
Rev. Sci. Instrum.
, vol.53
, Issue.7
, pp. 1053-1057
-
-
Roy, A.1
Buchanan, D.S.2
Ginsberg, D.M.3
-
4
-
-
0021380270
-
Measurement of magnetic susceptibility with the aid of quantum magnetometer
-
Kuznetsov V D 1984 Measurement of magnetic susceptibility with the aid of quantum magnetometer Sov. Phys. J. 27 (2) 118-26
-
(1984)
Sov. Phys. J.
, vol.27
, Issue.2
, pp. 118-126
-
-
Kuznetsov, V.D.1
-
5
-
-
1542684280
-
Non-uniform magnetisation and the vibrating sample magnetometer
-
2nd equation on p 1637
-
Guy C N and Howarth W 1978 Non-uniform magnetisation and the vibrating sample magnetometer J. Phys. C: Solid State Phys. 11 1635-50 2nd equation on p 1637
-
(1978)
J. Phys. C: Solid State Phys.
, vol.11
, pp. 1635-1650
-
-
Guy, C.N.1
Howarth, W.2
-
6
-
-
0027577940
-
The determination of magnetic moments of extended samples in a SQUID magnetometer
-
Blott B H and Daniell G J 1993 The determination of magnetic moments of extended samples in a SQUID magnetometer Meas. Sci. Technol. 4 462-7
-
(1993)
Meas. Sci. Technol.
, vol.4
, pp. 462-467
-
-
Blott, B.H.1
Daniell, G.J.2
-
7
-
-
0345818895
-
The response of longitudinal and transverse pick-up coils to a misaligned magnetic dipole
-
Miller L L 1996 The response of longitudinal and transverse pick-up coils to a misaligned magnetic dipole Rev. Sci. Instrum. 67 3201-7
-
(1996)
Rev. Sci. Instrum.
, vol.67
, pp. 3201-3207
-
-
Miller, L.L.1
-
8
-
-
0020176931
-
Detection coil, sensitivity function, and sample geometry effects for vibrating sample magnetometers
-
Zieba A and Foner S 1982 Detection coil, sensitivity function, and sample geometry effects for vibrating sample magnetometers Rev. Sci. Instrum. 53 1344-54
-
(1982)
Rev. Sci. Instrum.
, vol.53
, pp. 1344-1354
-
-
Zieba, A.1
Foner, S.2
-
9
-
-
1542684285
-
Erratum: Detection coil, sensitivity function, and sample geometry effects for vibrating sample magnetometers
-
Zieba A and Foner S 1991 Erratum: Detection coil, sensitivity function, and sample geometry effects for vibrating sample magnetometers Rev. Sci. Instrum. 62 2293
-
(1991)
Rev. Sci. Instrum.
, vol.62
, pp. 2293
-
-
Zieba, A.1
Foner, S.2
-
10
-
-
1542579539
-
Macroscopic domains in CuMn spin glasses: I. Observation
-
Guy C N 1982 Macroscopic domains in CuMn spin glasses: I. Observation J. Phys. F: Met. Phys. 12 1453-65
-
(1982)
J. Phys. F: Met. Phys.
, vol.12
, pp. 1453-1465
-
-
Guy, C.N.1
-
11
-
-
0025505665
-
A reappraisal of irreversible behaviour in the intermediate state of a type-I superconductor
-
Grover A K, Kumar R, Chaddah P, Subramanian C K and Sankaranarayanan V 1990 A reappraisal of irreversible behaviour in the intermediate state of a type-I superconductor Physica C 170 431-6
-
(1990)
Physica C
, vol.170
, pp. 431-436
-
-
Grover, A.K.1
Kumar, R.2
Chaddah, P.3
Subramanian, C.K.4
Sankaranarayanan, V.5
-
12
-
-
0020829912
-
Effect of sample and magnetometer dimensions on the flux detected by a SQUID magnetometer
-
Osterman D P and Williamson S J 1983 Effect of sample and magnetometer dimensions on the flux detected by a SQUID magnetometer Rev. Sci. Instrum. 54 (10) 1380-2 Osterman D P and Williamson S J 1984 Erratum: Effect of sample and magnetometer dimensions on the flux detected by a SQUID magnetometer Rev. Sci. Instrum. 55 (5) 818
-
(1983)
Rev. Sci. Instrum.
, vol.54
, Issue.10
, pp. 1380-1382
-
-
Osterman, D.P.1
Williamson, S.J.2
-
13
-
-
36549103537
-
Erratum: Effect of sample and magnetometer dimensions on the flux detected by a SQUID magnetometer
-
Osterman D P and Williamson S J 1983 Effect of sample and magnetometer dimensions on the flux detected by a SQUID magnetometer Rev. Sci. Instrum. 54 (10) 1380-2 Osterman D P and Williamson S J 1984 Erratum: Effect of sample and magnetometer dimensions on the flux detected by a SQUID magnetometer Rev. Sci. Instrum. 55 (5) 818
-
(1984)
Rev. Sci. Instrum.
, vol.55
, Issue.5
, pp. 818
-
-
Osterman, D.P.1
Williamson, S.J.2
-
14
-
-
1542474884
-
Elimination of the induced current error in magnetometers using superconducting flux transformers
-
Dummer D and Weyhmann W 1987 Elimination of the induced current error in magnetometers using superconducting flux transformers Rev. Sci. Instrum. 58 (10) 1933-6
-
(1987)
Rev. Sci. Instrum.
, vol.58
, Issue.10
, pp. 1933-1936
-
-
Dummer, D.1
Weyhmann, W.2
-
15
-
-
0016509109
-
Coupling considerations for SQUID devices
-
Claassen J H 1975 Coupling considerations for SQUID devices J. Appl. Phys. 46 (5) 2268-75
-
(1975)
J. Appl. Phys.
, vol.46
, Issue.5
, pp. 2268-2275
-
-
Claassen, J.H.1
-
16
-
-
0022874278
-
Elimination of flux-transformer crosstalk in multichannel SQUID magnetometers
-
terBrake H J M, Fleuren F H, Ulfman J A and Flokstra J 1986 Elimination of flux-transformer crosstalk in multichannel SQUID magnetometers Cryogenics 26 (12) 667-70
-
(1986)
Cryogenics
, vol.26
, Issue.12
, pp. 667-670
-
-
TerBrake, H.J.M.1
Fleuren, F.H.2
Ulfman, J.A.3
Flokstra, J.4
-
20
-
-
0028401201
-
Pick-up systems for vibrating sample magnetometers - A theoretical discussion based on magnetic multipole expansions
-
Außerlechner U, Kasperkovitz P and Steiner W 1994 Pick-up systems for vibrating sample magnetometers - a theoretical discussion based on magnetic multipole expansions Meas. Sci. Technol. 5 213-25
-
(1994)
Meas. Sci. Technol.
, vol.5
, pp. 213-225
-
-
Außerlechner, U.1
Kasperkovitz, P.2
Steiner, W.3
-
21
-
-
85034742764
-
-
Thesis Technical University of Vienna, Austria table 6.1, model S603 by Cryogenics Ltd
-
Holubar Th 1995 3-achsen SQUID-magnetometrie Thesis Technical University of Vienna, Austria (table 6.1, p 44; model S603 by Cryogenics Ltd)
-
(1995)
3-achsen SQUID-magnetometrie
, pp. 44
-
-
Holubar, Th.1
-
22
-
-
0028401201
-
Pick-up systems for vibrating sample magnetometers - A theoretical discussion based on magnetic multipole expansions
-
equation (10) Außerlechner U 1996 Vector pick-up system for high field vibrating sample magnetometers Thesis Technical University of Vienna, Austria, equation (6.9)
-
Außerlechner U, Kasperkovitz P and Steiner W 1994 Pick-up systems for vibrating sample magnetometers - a theoretical discussion based on magnetic multipole expansions Meas. Sci. Technol. 5 213-25, equation (10) Außerlechner U 1996 Vector pick-up system for high field vibrating sample magnetometers Thesis Technical University of Vienna, Austria, equation (6.9)
-
(1994)
Meas. Sci. Technol.
, vol.5
, pp. 213-225
-
-
Außerlechner, U.1
Kasperkovitz, P.2
Steiner, W.3
-
23
-
-
0016881808
-
Superconducting magnetometer for high resolution susceptibility measurements
-
Cerdonio M, Cosmelli C, Romani G L, Messana C and Gramaccioni C 1976 Superconducting magnetometer for high resolution susceptibility measurements Rev. Sci. Instrum. 47 1-5
-
(1976)
Rev. Sci. Instrum.
, vol.47
, pp. 1-5
-
-
Cerdonio, M.1
Cosmelli, C.2
Romani, G.L.3
Messana, C.4
Gramaccioni, C.5
-
24
-
-
0015976853
-
Magnetic susceptibility measurement using a superconducting magnetometer
-
Cukauskas E J, Vincent D A and Deaver B S Jr 1973 Magnetic susceptibility measurement using a superconducting magnetometer Rev. Sci. Instrum. 45 (1) 1-6
-
(1973)
Rev. Sci. Instrum.
, vol.45
, Issue.1
, pp. 1-6
-
-
Cukauskas, E.J.1
Vincent, D.A.2
Deaver Jr., B.S.3
-
25
-
-
0001075424
-
A sample holder design and calibration technique for the quantum design magnetic properties measurement system superconducting quantum interference device magnetometer
-
MPMS system by Quantum Design Inc
-
Lewis L H and Bussmann K M 1996 A sample holder design and calibration technique for the quantum design magnetic properties measurement system superconducting quantum interference device magnetometer Rev. Sci. Instrum. 67 3537-42 (MPMS system by Quantum Design Inc)
-
(1996)
Rev. Sci. Instrum.
, vol.67
, pp. 3537-3542
-
-
Lewis, L.H.1
Bussmann, K.M.2
-
29
-
-
0001944421
-
The theory of vector spherical harmonics
-
Hill E L 1953 The theory of vector spherical harmonics Am. J. Phys. 22 211-4
-
(1953)
Am. J. Phys.
, vol.22
, pp. 211-214
-
-
Hill, E.L.1
-
30
-
-
0001152670
-
Addition theorems for spherical wave solutions of the vector Helmholtz equation
-
Felderhof B U and Jones R B 1987 Addition theorems for spherical wave solutions of the vector Helmholtz equation J. Math. Phys. 28 836-9
-
(1987)
J. Math. Phys.
, vol.28
, pp. 836-839
-
-
Felderhof, B.U.1
Jones, R.B.2
-
31
-
-
1542789587
-
Design of a detection coil system for a biaxial VSM and some applications
-
Bernards J P C 1993 Design of a detection coil system for a biaxial VSM and some applications Rev. Sci. Instrum. 64 (7) 1918-30
-
(1993)
Rev. Sci. Instrum.
, vol.64
, Issue.7
, pp. 1918-1930
-
-
Bernards, J.P.C.1
-
34
-
-
0020704107
-
Superconducting magnet image effects observed with a vibrating sample magnetometer
-
Zieba A and Foner S 1983 Superconducting magnet image effects observed with a vibrating sample magnetometer Rev. Sci. Instrum. 54 137-45
-
(1983)
Rev. Sci. Instrum.
, vol.54
, pp. 137-145
-
-
Zieba, A.1
Foner, S.2
|