메뉴 건너뛰기




Volumn 2, Issue 6, 1996, Pages 387-391

Arteriovenous access fistulae diminish cardiac reserve, anaerobic threshold and work capacity: A case for fistula closure in stable renal transplant recipients

Author keywords

Anaerobic threshold; Arteriovenous fistula; Cardiac output; Renal transplantation; Work capacity

Indexed keywords


EID: 1542528229     PISSN: 13205358     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1440-1797.1996.tb00118.x     Document Type: Article
Times cited : (1)

References (13)
  • 1
    • 0028888359 scopus 로고
    • Proceedings: Symposium on Renal Replacement Therapy throughout the world: The Registries
    • D'Amico G, Striker GE (eds). Proceedings: Symposium on Renal Replacement Therapy throughout the world: The Registries. Am. J. Kidney Dis. 1995; 25: 113-205.
    • (1995) Am. J. Kidney Dis. , vol.25 , pp. 113-205
    • D'Amico, G.1    Striker, G.E.2
  • 2
    • 0029144535 scopus 로고
    • Ischemic heart disease: A major cause of death and graft loss after renal transplantation in Scandinavia
    • Lindholm A, Albrechtsen D, Frodin L, Tufveson G, Persson NH, Lundgren G. Ischemic heart disease: A major cause of death and graft loss after renal transplantation in Scandinavia. Transplantation 1995; 60: 451-7.
    • (1995) Transplantation , vol.60 , pp. 451-457
    • Lindholm, A.1    Albrechtsen, D.2    Frodin, L.3    Tufveson, G.4    Persson, N.H.5    Lundgren, G.6
  • 3
    • 0024394986 scopus 로고
    • Role of anaemia in the pathogenesis of left ventricular hypertrophy in end-stage renal disease
    • Silherber JS, Rahal DP, Barre P et al. Role of anaemia in the pathogenesis of left ventricular hypertrophy in end-stage renal disease. Am. J. Cardiol. 1989; 64: 222-4.
    • (1989) Am. J. Cardiol. , vol.64 , pp. 222-224
    • Silherber, J.S.1    Rahal, D.P.2    Barre, P.3
  • 4
    • 0019520998 scopus 로고
    • Cardiac effects of chronic renal failure and haemodialysis treatment
    • Ikaheimo M, Huttunen K, Takkunen J. Cardiac effects of chronic renal failure and haemodialysis treatment. Br. Heart J. 1981; 45: 710-16.
    • (1981) Br. Heart J. , vol.45 , pp. 710-716
    • Ikaheimo, M.1    Huttunen, K.2    Takkunen, J.3
  • 5
    • 0015379043 scopus 로고
    • Heart failure as a complication of hemodialysis arteriovenous fistula
    • Ahern DJ, Maher JF. Heart failure as a complication of hemodialysis arteriovenous fistula. Ann. Intern. Med. 1972; 77: 201-4.
    • (1972) Ann. Intern. Med. , vol.77 , pp. 201-204
    • Ahern, D.J.1    Maher, J.F.2
  • 6
    • 0028087874 scopus 로고
    • Banding a hemodialysis arteriovenous fistula to decrease blood flow and resolve high output cardiac failure: Report of a case
    • Isoda S, Kajiwara H, Kondo J, Matsumoto A. Banding a hemodialysis arteriovenous fistula to decrease blood flow and resolve high output cardiac failure: Report of a case. Surg. Today 1994; 24: 734-6.
    • (1994) Surg. Today , vol.24 , pp. 734-736
    • Isoda, S.1    Kajiwara, H.2    Kondo, J.3    Matsumoto, A.4
  • 7
    • 0025815841 scopus 로고
    • Measurement of aortic blood flow by Doppler echocardiography: Day to day variability in normal subjects and applicability in clinical research
    • Mouliner L, Venet T, Schiller NB, Kurtz TW, Morris RC, Sebastian A. Measurement of aortic blood flow by Doppler echocardiography: Day to day variability in normal subjects and applicability in clinical research. JACC 1991; 17: 1326-3.
    • (1991) JACC , vol.17 , pp. 1326-1333
    • Mouliner, L.1    Venet, T.2    Schiller, N.B.3    Kurtz, T.W.4    Morris, R.C.5    Sebastian, A.6
  • 8
    • 0022542458 scopus 로고
    • A new method for detecting anaerobic threshold by gas exchange
    • Beaver WL, Wasserman K, Whipp BJ. A new method for detecting anaerobic threshold by gas exchange. J. Appl. Physiol. 1986; 60: 2020-7.
    • (1986) J. Appl. Physiol. , vol.60 , pp. 2020-2027
    • Beaver, W.L.1    Wasserman, K.2    Whipp, B.J.3
  • 11
    • 0020460262 scopus 로고
    • Metabolic aspects of maximal exercise performance after slow release metoprolol and after atenolol
    • Folgering HT, Borm JF, van-Haaren RH. Metabolic aspects of maximal exercise performance after slow release metoprolol and after atenolol. Eur. J. Clin. Pharmacol. 1982; 23: 283-8.
    • (1982) Eur. J. Clin. Pharmacol. , vol.23 , pp. 283-288
    • Folgering, H.T.1    Borm, J.F.2    Van-Haaren, R.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.