메뉴 건너뛰기




Volumn 5, Issue , 2003, Pages 496-501

A binarization approach for CT-MR registration using normalized mutual information

Author keywords

Binarization; Multi resolution; Normalized mutual information; Registration

Indexed keywords

BINARIZATION; MULTI-RESOLUTION; NORMALIZED MUTUAL INFORMATIONS; REGISTRATION;

EID: 1542516519     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (2)

References (14)
  • 3
    • 0000190431 scopus 로고
    • Automated multi-modality image registration based on information theory
    • 1995, Y. Bizais, C. Barillot, and R. Di Paola, Eds., Dordrecht, Kluwer Acdemic, The Netherlands
    • A. Collignon, F. Maes, D. Delaere, D. Vandermeulen, P. Suetens, and G. Marchal. Automated multi-modality image registration based on information theory.: Information Process. Med. Imaging. 1995, Y. Bizais, C. Barillot, and R. Di Paola, Eds., 263-274, Dordrecht, Kluwer Acdemic, The Netherlands, 1995.
    • (1995) Information Process. Med. Imaging , pp. 263-274
    • Collignon, A.1    Maes, F.2    Delaere, D.3    Vandermeulen, D.4    Suetens, P.5    Marchal, G.6
  • 5
    • 0032762144 scopus 로고    scopus 로고
    • An overlap invariant entropy measure of 3D medical image alignment
    • C. Studholme, D.L.G. Hill, and D.J. Hawkes. An overlap invariant entropy measure of 3D medical image alignment. Pattern Recognition., 32(1):71-86, 1999.
    • (1999) Pattern Recognition , vol.32 , Issue.1 , pp. 71-86
    • Studholme, C.1    Hill, D.L.G.2    Hawkes, D.J.3
  • 8
    • 0033251944 scopus 로고    scopus 로고
    • Comparative evaluation of multiresolution optimization strategies for multimodality image registration by maximization of mutual information
    • F. Maes, D. Vandermeulen, and P. Suetens. Comparative evaluation of multiresolution optimization strategies for multimodality image registration by maximization of mutual information. Medical Image Analysis., 3:373-386, 1999.
    • (1999) Medical Image Analysis , vol.3 , pp. 373-386
    • Maes, F.1    Vandermeulen, D.2    Suetens, P.3
  • 11
    • 0036173417 scopus 로고    scopus 로고
    • Influence of implementation parameters on registration of MR and SPECT brain images by maximization of mutual information
    • Y. Zhu and S.M. Cochoff. Influence of implementation parameters on registration of MR and SPECT brain images by maximization of mutual information. The Journal of Nuclear Medicine., 43(2):160-166, 2002.
    • (2002) The Journal of Nuclear Medicine , vol.43 , Issue.2 , pp. 160-166
    • Zhu, Y.1    Cochoff, S.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.