메뉴 건너뛰기




Volumn 3, Issue , 2001, Pages 595-602

Dynamics of field amplified sample stacking

Author keywords

[No Author keywords available]

Indexed keywords

AMPLIFICATION; CONCENTRATION (PROCESS); ELECTRIC CONDUCTIVITY; ELECTRIC FIELD EFFECTS; ELECTROLYTES; ELECTROMIGRATION; ELECTROOSMOSIS; MATHEMATICAL MODELS; PRESSURE EFFECTS; VISCOSITY;

EID: 1542432769     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (3)

References (17)
  • 1
    • 0034501775 scopus 로고    scopus 로고
    • Dispersive Phenomena in Electromigration Separation Methods
    • Gas, B., and Kenndler, E., 2000, "Dispersive Phenomena in Electromigration Separation Methods," Electrophoresis, 21, pp. 3888-3897.
    • (2000) Electrophoresis , vol.21 , pp. 3888-3897
    • Gas, B.1    Kenndler, E.2
  • 3
    • 0033816077 scopus 로고    scopus 로고
    • On-line Preconcentration Methods for Capillary Electrophoresis
    • Osbourn, D.M., Weiss D.J., and Lunte, C.E., 2000,"On-line Preconcentration Methods for Capillary Electrophoresis," Electrophoresis, 21, pp. 2768-2779.
    • (2000) Electrophoresis , vol.21 , pp. 2768-2779
    • Osbourn, D.M.1    Weiss, D.J.2    Lunte, C.E.3
  • 6
    • 37049187574 scopus 로고
    • Electrophoresis: Mathematical Modeling and Computer Simulation
    • Bier, M., Palusinski, O.A., Mosher, R.A., and Saville, D.A., 1983, "Electrophoresis: Mathematical Modeling and Computer Simulation," Science, 219, pp. 1281-1287.
    • (1983) Science , vol.219 , pp. 1281-1287
    • Bier, M.1    Palusinski, O.A.2    Mosher, R.A.3    Saville, D.A.4
  • 10
    • 0026827189 scopus 로고
    • Electrokinetics of the silica-soltion interface: A flat plate streaming potential study
    • Scales, P.J., Grieser, F., and Healy, T.W., 1992, "Electrokinetics of the silica-soltion interface: a flat plate streaming potential study," Langmuir, 8, pp. 965-974.
    • (1992) Langmuir , vol.8 , pp. 965-974
    • Scales, P.J.1    Grieser, F.2    Healy, T.W.3
  • 11
    • 0000743079 scopus 로고
    • Optimization in Sample Stacking for High Performance Capillary Electrophoresis
    • Burgi, D.S., and Chien, R.L., 1991, "Optimization in Sample Stacking for High Performance Capillary Electrophoresis," Analytical Chemistry, 63, pp. 2042-2047
    • (1991) Analytical Chemistry , vol.63 , pp. 2042-2047
    • Burgi, D.S.1    Chien, R.L.2
  • 12
    • 0028932361 scopus 로고
    • Microchip Electrophoresis with Sample Stacking
    • Jacobson, S.C., and Ramsey, J.M., 1995, "Microchip Electrophoresis with Sample Stacking," Electrophoresis, 16, pp. 481-486.
    • (1995) Electrophoresis , vol.16 , pp. 481-486
    • Jacobson, S.C.1    Ramsey, J.M.2
  • 13
    • 0035145458 scopus 로고    scopus 로고
    • Sample Preconcentration by Field Amplification Satcking for Microchip-Based Capillary Electrophoresis
    • Lichtenberg, J., Verpoorte, E., and Rooji, N.F., 2001, "Sample Preconcentration by Field Amplification Satcking for Microchip-Based Capillary Electrophoresis," Electrophoresis, 22, pp. 258-271.
    • (2001) Electrophoresis , vol.22 , pp. 258-271
    • Lichtenberg, J.1    Verpoorte, E.2    Rooji, N.F.3
  • 17
    • 84963178275 scopus 로고
    • Electroosmosis Through Pores with Nonuniformly Charged Walls
    • Anderson, J.L., and Idol, W.K., 1985, "Electroosmosis Through Pores with Nonuniformly Charged Walls," Chemical Engineering Communications, 38, pp. 93-106.
    • (1985) Chemical Engineering Communications , vol.38 , pp. 93-106
    • Anderson, J.L.1    Idol, W.K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.