메뉴 건너뛰기




Volumn 19, Issue 3, 2004, Pages 308-312

Brief report: Validation of a system for automated measurement of knee laxity

Author keywords

AP drawer; Fluoroscope; Knee; Laxity

Indexed keywords

DIAGNOSIS; IMAGE ANALYSIS; JOINTS (ANATOMY); LIGAMENTS; TRANSDUCERS;

EID: 1542375391     PISSN: 02680033     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.clinbiomech.2003.12.004     Document Type: Article
Times cited : (5)

References (11)
  • 1
    • 0030175447 scopus 로고    scopus 로고
    • Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy
    • Banks S.A., Hodge W.A. Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy. IEEE Trans. Biomed. Eng. 43:1996;638-649.
    • (1996) IEEE Trans. Biomed. Eng. , vol.43 , pp. 638-649
    • Banks, S.A.1    Hodge, W.A.2
  • 4
    • 0034884522 scopus 로고    scopus 로고
    • Accuracy and repeatability of Roentgen stereophotogrammetric analysis (RSA) for measuring knee laxity in longitudinal studies
    • Fleming B.C., Peura G.D., Abate J.A., Beynnon B.D. Accuracy and repeatability of Roentgen stereophotogrammetric analysis (RSA) for measuring knee laxity in longitudinal studies. J. Biomech. 34:2001;1355-1359.
    • (2001) J. Biomech. , vol.34 , pp. 1355-1359
    • Fleming, B.C.1    Peura, G.D.2    Abate, J.A.3    Beynnon, B.D.4
  • 6
    • 0024820164 scopus 로고
    • Genucom, KT-1000, and Stryker knee laxity measuring device comparisons. Device reproducibility and interdevice comparison in asymptomatic subjects
    • Highgenboten C.L., Jackson A., Meske N.B. Genucom, KT-1000, and Stryker knee laxity measuring device comparisons. Device reproducibility and interdevice comparison in asymptomatic subjects. Am. J. Sports Med. 17:1989;743-746.
    • (1989) Am. J. Sports Med. , vol.17 , pp. 743-746
    • Highgenboten, C.L.1    Jackson, A.2    Meske, N.B.3
  • 8
    • 0025114477 scopus 로고
    • Measurement of anterior-posterior displacement of the knee. A comparison of the results with instrumented devices and with clinical examination
    • Steiner M.E., Brown C., Zarins B., Brownstein B., Koval P.S., Stone P. Measurement of anterior-posterior displacement of the knee. A comparison of the results with instrumented devices and with clinical examination. J. Bone Joint Surg. Am. 72:1990;1307-1315.
    • (1990) J. Bone Joint Surg. Am. , vol.72 , pp. 1307-1315
    • Steiner, M.E.1    Brown, C.2    Zarins, B.3    Brownstein, B.4    Koval, P.S.5    Stone, P.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.