-
1
-
-
0006074730
-
Accuracy Evaluation of Optically Pumped Primary Frequency Standard CRL-01
-
A. Hasegawa, K. Fukuda, M. Kajita, H. Ito, M. Kumagai, M. Hosokawa, N, Kotake, T. Morikawa, "Accuracy Evaluation of Optically Pumped Primary Frequency Standard CRL-01", Proceedings of ATF2000, pp. 199-205, 2000
-
(2000)
Proceedings of ATF2000
, pp. 199-205
-
-
Hasegawa, A.1
Fukuda, K.2
Kajita, M.3
Ito, H.4
Kumagai, M.5
Hosokawa, M.6
Kotake, N.7
Morikawa, T.8
-
2
-
-
1542334259
-
-
unpblished
-
Atsushi Hasegawa, Kyoya Fukuda, Masatoshi Kajita, Hiroyuki Ito, Motohiro Kumagai, Mizuhiko Hosokawa, Noboru Kotake, and Takao Morikawa:"Accuracy Evaluation of Optically Pumped Primary Frequency Standard CRL-O1" unpblished
-
Accuracy Evaluation of Optically Pumped Primary Frequency Standard CRL-O1
-
-
Hasegawa, A.1
Fukuda, K.2
Kajita, M.3
Ito, H.4
Kumagai, M.5
Hosokawa, M.6
Kotake, N.7
Morikawa, T.8
-
3
-
-
0029292752
-
A Cesium Fountain Frequency Standard: Preliminary Results
-
A. Clairon, P. Laurent, G. Satntarelli, S. Ghezali, SN. Lea, M, Bahoura, "A Cesium Fountain Frequency Standard: Preliminary Results", IEEE Trans. Instrum. Meas., 44, pp.128-131, 1995
-
(1995)
IEEE Trans. Instrum. Meas.
, vol.44
, pp. 128-131
-
-
Clairon, A.1
Laurent, P.2
Satntarelli, G.3
Ghezali, S.4
Lea, S.N.5
Bahoura, M.6
-
4
-
-
0035217651
-
Uncertainty evaluation of the atomic Caesium fountain CSF1 of the PTB
-
S, Weyers, U. Hübner, R. Schröder, Chr. Tamm, A. Bauch, "Uncertainty evaluation of the atomic Caesium fountain CSF1 of the PTB" Melrologia, 38, pp.343-352, 2001
-
(2001)
Melrologia
, vol.38
, pp. 343-352
-
-
Weyers, S.1
Hübner, U.2
Schröder, R.3
Tamm, Chr.4
Bauch, A.5
-
5
-
-
0036949947
-
Accuracy Evaluation of NIST-F1
-
S.R. Jefferts, J. Shirley, T.E. Parker, T.P. Heavner, D.M. Meekhof, C.W. Nelson, F. Levi, G. Costanzo, A. De Marchi, R.E. Drullinger, L. Hollberg, W.D. Lee and F.L. Walls: "Accuracy Evaluation of NIST-F1", Metrologia, 39. pp321-326, 2002
-
(2002)
Metrologia
, vol.39
, pp. 321-326
-
-
Jefferts, S.R.1
Shirley, J.2
Parker, T.E.3
Heavner, T.P.4
Meekhof, D.M.5
Nelson, C.W.6
Levi, F.7
Costanzo, G.8
De Marchi, A.9
Drullinger, R.E.10
Hollberg, L.11
Lee, W.D.12
Walls, F.L.13
-
6
-
-
1542304222
-
Cesium Fountain Development at CRL
-
K. Fukuda, H. Ito, M. Kumagai, M. Kajita, A. Hasegawa, M. Hosokawa, T, Morikawa, "Cesium Fountain Development at CRL" Proceedings of ATF2000, pp. 217-223, 2000
-
(2000)
Proceedings of ATF2000
, pp. 217-223
-
-
Fukuda, K.1
Ito, H.2
Kumagai, M.3
Kajita, M.4
Hasegawa, A.5
Hosokawa, M.6
Morikawa, T.7
-
7
-
-
1542363970
-
Development of Cs Atomic Fountain Frequency Standard at CRL
-
M. Kumagai, H. Ito, K. Fukuda, M. Kajita, M. Hosokawa and T. Morikawa: ''Development of Cs Atomic Fountain Frequency Standard at CRL" Proc. of ATF2002, pp. 150-155, 2002
-
(2002)
Proc. of ATF2002
, pp. 150-155
-
-
Kumagai, M.1
Ito, H.2
Fukuda, K.3
Kajita, M.4
Hosokawa, M.5
Morikawa, T.6
|