메뉴 건너뛰기




Volumn 4, Issue , 2003, Pages 3169-3172

A PC-Based System for H-Reflex and Single Sweep SEP Coupled Monitoring of Spinal Cord Function in Vertebral Column Surgery

Author keywords

H reflex; Neuromonitoring; Scoliosis; Single sweep SEP; Spinal cord injury; Stimulator

Indexed keywords

AMPLIFIERS (ELECTRONIC); BIOELECTRIC POTENTIALS; DATA ACQUISITION; DIGITAL SIGNAL PROCESSING; ELECTROSURGERY; FUNCTIONAL ELECTRIC STIMULATION; FUNCTIONAL NEURAL STIMULATION; GAIN MEASUREMENT; MEDICAL APPLICATIONS; MUSCULOSKELETAL SYSTEM; PATIENT MONITORING; PERSONAL COMPUTERS; SPURIOUS SIGNAL NOISE; SWEEP CIRCUITS; TRIGGER CIRCUITS;

EID: 1542360544     PISSN: 05891019     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (2)

References (12)
  • 2
    • 1542344281 scopus 로고
    • H-Reflex spinal cord monitoring during vertebral column stabilization surgery
    • J. Boyd, Ed. London: Kluwer A.P.
    • F. Bracchi, P. Grossi, L. Trovati, and P. Viganò, "H-Reflex spinal cord monitoring during vertebral column stabilization surgery," in Handbook of Spinal Cord Monitoring, J. Boyd, Ed. London: Kluwer A.P., 1992, pp. 253-258.
    • (1992) Handbook of Spinal Cord Monitoring , pp. 253-258
    • Bracchi, F.1    Grossi, P.2    Trovati, L.3    Viganò, P.4
  • 4
    • 0023223798 scopus 로고
    • Single sweep analysis of visual evoked potentials through a model of parametric identification
    • S. Cerutti, G. Baselli, D. Liberati, and G. Pavesi, "Single sweep analysis of visual evoked potentials through a model of parametric identification," in Biol. Cybern., vol. 56, p.p. 111-120, 1987.
    • (1987) Biol. Cybern. , vol.56 , pp. 111-120
    • Cerutti, S.1    Baselli, G.2    Liberati, D.3    Pavesi, G.4
  • 8
    • 0028746879 scopus 로고
    • A programmable electronic stimulator for FES systems
    • Dec.
    • Milan Ilic', Dragan Vasiljevic', and Dejan B. Popovic', "A programmable electronic stimulator for FES systems," IEEE Trans. Rehab. Eng., vol. 45, pp. 234-238, Dec. 1994.
    • (1994) IEEE Trans. Rehab. Eng. , vol.45 , pp. 234-238
    • Ilic, M.1    Vasiljevic, D.2    Popovic, D.B.3
  • 9
    • 0031962536 scopus 로고    scopus 로고
    • A versatile microprocessor-based multichannel stimulator for skeletal muscle cardiac assist
    • Jan.
    • E. A. Cheever, D. R. Thompson, B. L. Cmolik, W. P. Santamore, and D. T. George, "A versatile microprocessor-based multichannel stimulator for skeletal muscle cardiac assist," IEEE Trans. Biomed. Eng., vol. 45, pp. 56-67, Jan. 1998.
    • (1998) IEEE Trans. Biomed. Eng. , vol.45 , pp. 56-67
    • Cheever, E.A.1    Thompson, D.R.2    Cmolik, B.L.3    Santamore, W.P.4    George, D.T.5
  • 10
    • 0036476803 scopus 로고    scopus 로고
    • A versatile multichannel direct-synthesized electrical stimulator for FES application
    • Feb.
    • Han-Chang Wu, Shuenn-Tsong Young, and Te-Son Kuo, "A versatile multichannel direct-synthesized electrical stimulator for FES application, " IEEE Trans. Instrum. Meas., vol. 51, Feb. 2002.
    • (2002) IEEE Trans. Instrum. Meas. , vol.51
    • Wu, H.-C.1    Young, S.-T.2    Kuo, T.-S.3
  • 11
    • 1542344280 scopus 로고    scopus 로고
    • Regulated-Current versus Regulated-Voltage Stimulation
    • Ed. NewYork: Springer
    • J. P. Reilly "Regulated-Current versus Regulated-Voltage Stimulation," in Applied Bioelectricity, 2nd ed., Ed. NewYork: Springer, 1998, pp. 309-310.
    • (1998) Applied Bioelectricity, 2nd Ed. , pp. 309-310
    • Reilly, J.P.1
  • 12
    • 0024691812 scopus 로고
    • The implementation of an autoregressive model with exogenous input in a single sweep visual evoked potential
    • D. Liberati, and S. Cerutti, "The implementation of an autoregressive model with exogenous input in a single sweep visual evoked potential," J. Biomed. Eng., vol. 11, p.p. 285-292, 1989.
    • (1989) J. Biomed. Eng. , vol.11 , pp. 285-292
    • Liberati, D.1    Cerutti, S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.