-
1
-
-
0028087215
-
Risk of replacement of descending aorta with a standardized left bypass technique
-
Borst HG, Jurmann M, Buhner B, et al. Risk of replacement of descending aorta with a standardized left bypass technique. J Thorac Cardiovasc Surg. 1994;107:125-33.
-
(1994)
J Thorac Cardiovasc Surg
, vol.107
, pp. 125-133
-
-
Borst, H.G.1
Jurmann, M.2
Buhner, B.3
-
2
-
-
0033739612
-
Stenting versus surgery of the thoracic aorta
-
Ince H, Nienaber CA. Stenting versus surgery of the thoracic aorta. J Interv Cardiol. 2000;13:469-74.
-
(2000)
J Interv Cardiol
, vol.13
, pp. 469-474
-
-
Ince, H.1
Nienaber, C.A.2
-
3
-
-
0027336410
-
1993 Update: Descending aortic aneurysmectomy without adjuncts to avoid ischemia
-
Najafi H. 1993 update: descending aortic aneurysmectomy without adjuncts to avoid ischemia. Ann Thorac Surg. 1993;55:1042-5.
-
(1993)
Ann Thorac Surg
, vol.55
, pp. 1042-1045
-
-
Najafi, H.1
-
4
-
-
0242331802
-
Open versus endovascular repair of para-anastomotic aneurysms in patients who were morphological candidates for endovascular treatment
-
Gawenda M, Zaehringer M, Brunkwall J. Open versus endovascular repair of para-anastomotic aneurysms in patients who were morphological candidates for endovascular treatment. J Endovasc Ther. 2003;10:745-51.
-
(2003)
J Endovasc Ther
, vol.10
, pp. 745-751
-
-
Gawenda, M.1
Zaehringer, M.2
Brunkwall, J.3
-
5
-
-
0026267990
-
Clinical experience of the use of self-fixing synthetic prostheses for remote endoprosthetics of the thoracic and the abdominal aorta and iliac arteries through the femoral artery and as intraoperative endoprosthesis for aorta reconstruction
-
Volodos NL, Karpovich IP, Troyan VI, et al. Clinical experience of the use of self-fixing synthetic prostheses for remote endoprosthetics of the thoracic and the abdominal aorta and iliac arteries through the femoral artery and as intraoperative endoprosthesis for aorta reconstruction. Vasa. 1991;33(suppl):93-5.
-
(1991)
Vasa
, vol.33
, Issue.SUPPL.
, pp. 93-95
-
-
Volodos, N.L.1
Karpovich, I.P.2
Troyan, V.I.3
-
6
-
-
0028631110
-
Transluminal placement of endovascular stent-grafts for the treatment of descending thoracic aortic aneurysms
-
Dake MD, Miller DC, Semba CP, et al. Transluminal placement of endovascular stent-grafts for the treatment of descending thoracic aortic aneurysms. N Engl J Med. 1994;331:1729-34.
-
(1994)
N Engl J Med
, vol.331
, pp. 1729-1734
-
-
Dake, M.D.1
Miller, D.C.2
Semba, C.P.3
-
7
-
-
0029865278
-
Endovascular stent-graft repair of thoracic aortic aneurysms
-
Mitchell RS, Dake MD, Semba CP, et al. Endovascular stent-graft repair of thoracic aortic aneurysms. J Thorac Cardiovasc Surg. 1996;111:1054-62.
-
(1996)
J Thorac Cardiovasc Surg
, vol.111
, pp. 1054-1062
-
-
Mitchell, R.S.1
Dake, M.D.2
Semba, C.P.3
-
8
-
-
0032125753
-
Endovascular stent graft repair for aneurysms on the descending thoracic aorta
-
Ehrlich M, Grabenwöger M, Grimm M, et al. Endovascular stent graft repair for aneurysms on the descending thoracic aorta. Ann Thorac Surg. 1998;66:19-24.
-
(1998)
Ann Thorac Surg
, vol.66
, pp. 19-24
-
-
Ehrlich, M.1
Grabenwöger, M.2
Grimm, M.3
-
9
-
-
1542314235
-
Midterm results of endovascular repair of descending thoracic aortic aneurysms with first-generation stent grafts
-
Demers P, Miller DC, Mitchell RS, et al. Midterm results of endovascular repair of descending thoracic aortic aneurysms with first-generation stent grafts. J Thorac Cardiovasc Surg. 2004;127:664-73.
-
(2004)
J Thorac Cardiovasc Surg
, vol.127
, pp. 664-673
-
-
Demers, P.1
Miller, D.C.2
Mitchell, R.S.3
-
10
-
-
0037080916
-
Predicting death in patients with acute type a aortic dissection
-
Mehta RH, Suzuki T, Hagan PG, et al. Predicting death in patients with acute type a aortic dissection. Circulation. 2002;105(2):200-6.
-
(2002)
Circulation
, vol.105
, Issue.2
, pp. 200-206
-
-
Mehta, R.H.1
Suzuki, T.2
Hagan, P.G.3
-
11
-
-
0032774377
-
Transfemoral endografting of thoracic aortic aneurysm under local anesthesia: A simple, safe and fast track procedure
-
Lachat M, Pfammatter T, Turina M. Transfemoral endografting of thoracic aortic aneurysm under local anesthesia: a simple, safe and fast track procedure. Vasa. 1999;28:204-6.
-
(1999)
Vasa
, vol.28
, pp. 204-206
-
-
Lachat, M.1
Pfammatter, T.2
Turina, M.3
-
12
-
-
0036178375
-
Percutaneous deployment of a low-profile bifurcated stent-graft
-
Quinn SF, Duke DJ, Baldwin SS, et al. Percutaneous deployment of a low-profile bifurcated stent-graft. AJR Am J Roentgenol. 2002;178:654-6.
-
(2002)
AJR Am J Roentgenol
, vol.178
, pp. 654-656
-
-
Quinn, S.F.1
Duke, D.J.2
Baldwin, S.S.3
-
13
-
-
0027751619
-
Improved distal circulatory support for repair of descending thoracic aortic aneurysms
-
von Segesser LK, Killur I, Jenni R, et al. Improved distal circulatory support for repair of descending thoracic aortic aneurysms. Ann Thorac Surg. 1993;56:1373-80.
-
(1993)
Ann Thorac Surg
, vol.56
, pp. 1373-1380
-
-
Von Segesser, L.K.1
Killur, I.2
Jenni, R.3
-
14
-
-
0031600841
-
Spinal cord protection in descending thoracic and thoracoabdominal aortic aneurysm repair
-
Safi HJ, Campbell MP, Ferreira ML, et al. Spinal cord protection in descending thoracic and thoracoabdominal aortic aneurysm repair. Semin Thorac Cardiovasc Surg. 1998;10:41-4.
-
(1998)
Semin Thorac Cardiovasc Surg
, vol.10
, pp. 41-44
-
-
Safi, H.J.1
Campbell, M.P.2
Ferreira, M.L.3
-
15
-
-
1542309008
-
On the problem of a theory of scientific method
-
London: Routledge
-
Popper KR. On the problem of a theory of scientific method. In: The logic of scientific discovery. London: Routledge; 1992.
-
(1992)
The Logic of Scientific Discovery
-
-
Popper, K.R.1
-
16
-
-
0041662025
-
Aortic dissection: New frontiers in diagnosis and management; part II: Therapeutic management and follow-up
-
Nienaber CA, Eagle KA. Aortic dissection: new frontiers in diagnosis and management; part II: therapeutic management and follow-up. Circulation. 2003;108:772-8.
-
(2003)
Circulation
, vol.108
, pp. 772-778
-
-
Nienaber, C.A.1
Eagle, K.A.2
|