메뉴 건너뛰기




Volumn 2, Issue , 2003, Pages 1960-1963

Charge-injection waveforms for indium oxide (AIROF) microelectrodes

Author keywords

AIROF; Anodic bias; Charge injection; Iridium; Microelectrodes; Neural stimulation; Waveforms

Indexed keywords

ANODES; APPLICATION SPECIFIC INTEGRATED CIRCUITS; CHEMICAL ACTIVATION; CURRENT DENSITY; ELECTRIC CHARGE; ELECTROCHEMISTRY; FUNCTIONAL ELECTRIC STIMULATION; FUNCTIONAL NEURAL STIMULATION; IRIDIUM COMPOUNDS; NEUROPHYSIOLOGY; PULSE GENERATORS; THIN FILM DEVICES; WAVEFORM ANALYSIS;

EID: 1542331448     PISSN: 05891019     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (15)

References (9)
  • 1
    • 0022611152 scopus 로고
    • Neuronal activity evoked by chronically implanted intracortical microelectrodes
    • D. B. McCreery, L. A. Bullara, W. F. Agnew, "Neuronal activity evoked by chronically implanted intracortical microelectrodes," Exp. Neur., vol. 92, pp. 147-161, 1986.
    • (1986) Exp. Neur. , vol.92 , pp. 147-161
    • McCreery, D.B.1    Bullara, L.A.2    Agnew, W.F.3
  • 2
    • 0033198609 scopus 로고    scopus 로고
    • Stability of the interface between neural tissue and chronically implanted intracortical microelectrodes
    • X. Liu X, D. B. McCreery, R. R. Carter, L. A. Bullara, T. G. H. Yuen, W. F. Agnew, "Stability of the interface between neural tissue and chronically implanted intracortical microelectrodes," IEEE Trans. Rehab. Eng., vol. 7, pp. 315-326, 1999.
    • (1999) IEEE Trans. Rehab. Eng. , vol.7 , pp. 315-326
    • Liu, X.1    McCreery, D.B.2    Carter, R.R.3    Bullara, L.A.4    Yuen, T.G.H.5    Agnew, W.F.6
  • 3
    • 0033620873 scopus 로고    scopus 로고
    • Bladder and urethral pressures evoked by microstimulation of the sacral spinal cord in cats
    • W. M. Grill, N. Bhadra, B. Wang, "Bladder and urethral pressures evoked by microstimulation of the sacral spinal cord in cats," Brain Research, vol. 836, pp. 19-30, 1999.
    • (1999) Brain Research , vol.836 , pp. 19-30
    • Grill, W.M.1    Bhadra, N.2    Wang, B.3
  • 5
    • 0033932838 scopus 로고    scopus 로고
    • Chronic neural stimulation with thin-film, iridium oxide electrodes at high current densities
    • J. D. Weiland, D. J. Anderson, "Chronic neural stimulation with thin-film, iridium oxide electrodes at high current densities," IEEE Trans. Biomed Eng., vol. 35, pp. 911-918, 2000.
    • (2000) IEEE Trans. Biomed Eng. , vol.35 , pp. 911-918
    • Weiland, J.D.1    Anderson, D.J.2
  • 6
    • 0024027087 scopus 로고
    • Charge injection limits of activated iridium oxide electrodes with 0.2 ms pulses in bicarbonate buffered saline
    • X. Beebe, T. L. Rose, "Charge injection limits of activated iridium oxide electrodes with 0.2 ms pulses in bicarbonate buffered saline," IEEE Trans. Biomed. Eng., vol. 35, pp. 494-495, 1988.
    • (1988) IEEE Trans. Biomed. Eng. , vol.35 , pp. 494-495
    • Beebe, X.1    Rose, T.L.2
  • 7
    • 0002027562 scopus 로고
    • Electrochemical guidelines for selection of protocols and electrode materials for neural stimulation
    • W. F. Agnew, D. B. McCreery, editors. Prentice Hall: Englewood Cliffs NJ
    • L. S. Robblee, T. L. Rose, "Electrochemical guidelines for selection of protocols and electrode materials for neural stimulation." In W. F. Agnew, D. B. McCreery, editors. Neural Prostheses: Fundamental Studies. Prentice Hall: Englewood Cliffs NJ, pp. 25-66, 1990.
    • (1990) Neural Prostheses: Fundamental Studies , pp. 25-66
    • Robblee, L.S.1    Rose, T.L.2
  • 8
    • 0347927495 scopus 로고    scopus 로고
    • In vitro electrical properties of iridium oxide versus titanium nitride stimulating electrodes
    • J. D. Weiland, D. J. Anderson, M. S. Humayun, "In vitro electrical properties of iridium oxide versus titanium nitride stimulating electrodes," IEEE Trans. Biomed. Eng., vol. 49, pp. 1574-1579, 2002.
    • (2002) IEEE Trans. Biomed. Eng. , vol.49 , pp. 1574-1579
    • Weiland, J.D.1    Anderson, D.J.2    Humayun, M.S.3
  • 9
    • 0031260395 scopus 로고    scopus 로고
    • A characterization of the effects on neuronal excitability due to prolonged microstimulation with chronically implanted microelectrodes
    • D. B. McCreery, T. G. H. Yuen, W. F. Agnew, L. A. Bullara, "A characterization of the effects on neuronal excitability due to prolonged microstimulation with chronically implanted microelectrodes," IEEE Trans Biomed Eng., vol. 44, pp. 931-939, 1997.
    • (1997) IEEE Trans Biomed Eng. , vol.44 , pp. 931-939
    • McCreery, D.B.1    Yuen, T.G.H.2    Agnew, W.F.3    Bullara, L.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.