메뉴 건너뛰기




Volumn 4, Issue , 2003, Pages 3368-3371

Inductive Link Modeling and Design Guidelines for Optimum Power Transfer in Implantable Wireless Microsystems

Author keywords

Coupling coefficient; Inductive link; Integrated coil; Wireless microsystems

Indexed keywords

COMPUTER SIMULATION; COUPLINGS; CURRENT DENSITY; ELECTRIC COILS; ELECTRIC INDUCTORS; ELECTRIC POTENTIAL; ELECTRIC POWER TRANSMISSION; FINITE ELEMENT METHOD; NATURAL FREQUENCIES; TRANSMITTERS;

EID: 1542330615     PISSN: 05891019     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (12)

References (11)
  • 1
    • 0030083719 scopus 로고    scopus 로고
    • A High-Efficiency Power and Data Transmission System for Biomedical Implanted Electronic Devices
    • Z. Hamici, R. Itti, and J. Champier, "A High-Efficiency Power and Data Transmission System for Biomedical Implanted Electronic Devices," Meas. Sci. Technol., vol. 7, pp. 192-201, 1996.
    • (1996) Meas. Sci. Technol. , vol.7 , pp. 192-201
    • Hamici, Z.1    Itti, R.2    Champier, J.3
  • 2
    • 0017559930 scopus 로고
    • Design of Radio-Frequency Powered Coils for Implant Instruments
    • W. H. Ko, S, P. Liang, and C. D. F. Fung, "Design of Radio-Frequency Powered Coils for Implant Instruments," Med. & Bio. Eng. & Comput., no. 15, pp. 634-640, 1977.
    • (1977) Med. & Bio. Eng. & Comput. , Issue.15 , pp. 634-640
    • Ko, W.H.1    Liang, S.P.2    Fung, C.D.F.3
  • 3
    • 0021285916 scopus 로고
    • System Optimization for Improved Accuracy in Transcutaneous Signal and Power Transmission
    • February
    • E. S. Hochmair, "System Optimization for Improved Accuracy in Transcutaneous Signal and Power Transmission," IEEE Trans. Biomed Eng., vol. BME-31, no. 2, pp. 177-186, February 1984.
    • (1984) IEEE Trans. Biomed Eng. , vol.BME-31 , Issue.2 , pp. 177-186
    • Hochmair, E.S.1
  • 4
    • 0025457142 scopus 로고
    • High-Efficiency Coupling-Insensitive Transcutaneous Power and Data Transmission via an Inductive-link
    • July
    • C. M. Zierhofer and E. S. Hochmair, "High-Efficiency Coupling-Insensitive Transcutaneous Power and Data Transmission via an Inductive-link," IEEE Trans. Biomed. Eng., vol. 37, no. 7, pp. 716-722, July 1990.
    • (1990) IEEE Trans. Biomed. Eng. , vol.37 , Issue.7 , pp. 716-722
    • Zierhofer, C.M.1    Hochmair, E.S.2
  • 5
    • 0030200060 scopus 로고    scopus 로고
    • Geometric Approach for Coupling Enhancement of Magnetically Coupled Coils
    • July
    • C. M Zierhofer, "Geometric Approach for Coupling Enhancement of Magnetically Coupled Coils," IEEE Trans. Biomed. Eng., vol. 43, no. 7, pp. 708-714, July 1996.
    • (1996) IEEE Trans. Biomed. Eng. , vol.43 , Issue.7 , pp. 708-714
    • Zierhofer, C.M.1
  • 6
    • 0024693784 scopus 로고
    • An Advanced Multiple Channel Cochlear Implant
    • July
    • H. McDermott, "An Advanced Multiple Channel Cochlear Implant," IEEE Trans. Biomed. Eng., vol. 36, no. 7, pp. 789-797, July 1989.
    • (1989) IEEE Trans. Biomed. Eng. , vol.36 , Issue.7 , pp. 789-797
    • McDermott, H.1
  • 7
    • 0035386288 scopus 로고    scopus 로고
    • Signal Transmission System for High Frequency Magnetic Telemetry for an Artificial Heart
    • July
    • M. Takahashi, K. Wanatabe, F. Sato, and H. Matsuki, "Signal Transmission System for High Frequency Magnetic Telemetry for an Artificial Heart," IEEE Trans. On Magnetics, vol. 37, No, 4, pp. 2921-2924, July 2001.
    • (2001) IEEE Trans. On Magnetics , vol.37 , Issue.4 , pp. 2921-2924
    • Takahashi, M.1    Wanatabe, K.2    Sato, F.3    Matsuki, H.4
  • 8
    • 0003196681 scopus 로고    scopus 로고
    • Microsensors, Microactuators, and Microsystems
    • August
    • K. D. Wise, editor, "Microsensors, Microactuators, and Microsystems" Proceedings of the IEEE, Vol. 86, August 1998.
    • (1998) Proceedings of the IEEE , vol.86
    • Wise, K.D.1
  • 9
    • 0031260315 scopus 로고    scopus 로고
    • A Single-Channel Implantable Microstimulator for Functional Neuromuscular Stimulation
    • B. Ziaie, M. D. Nardin, A. T. Coghlan, and K Najafi, "A Single-Channel Implantable Microstimulator for Functional Neuromuscular Stimulation," IEEE trans. on Biomedical Engineering, Vol. 44, No. 10, pp. 909-920, 1997.
    • (1997) IEEE Trans. on Biomedical Engineering , vol.44 , Issue.10 , pp. 909-920
    • Ziaie, B.1    Nardin, M.D.2    Coghlan, A.T.3    Najafi, K.4
  • 10
    • 0026543093 scopus 로고
    • Class E driver for Transcutaneous Power and Data Link for Implanted Electronic Devices
    • P.R. Troyk, M.A Schwan, "Class E driver for Transcutaneous Power and Data Link for Implanted Electronic Devices", Med. & Biol. Eng. & Comput., 30, pp.69-75, 1992.
    • (1992) Med. & Biol. Eng. & Comput. , vol.30 , pp. 69-75
    • Troyk, P.R.1    Schwan, M.A.2
  • 11
    • 0242710346 scopus 로고    scopus 로고
    • A Wireless Single-Chip Telemetry-Powered Neural Stimulation System
    • J. A. Von Arx, and K. Najafi, "A Wireless Single-Chip Telemetry-Powered Neural Stimulation System," Solid-State Circuits Conference, ISSCC, 1999, Page(s): 214-215
    • (1999) Solid-state Circuits Conference, ISSCC , pp. 214-215
    • Von Arx, J.A.1    Najafi, K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.