메뉴 건너뛰기




Volumn 3, Issue , 2003, Pages 1609-1614

Optimal And Adaptive Active Filtering Under Non Stiff and Distorted Voltage Conditions

Author keywords

Harmonics; IEEE 519; Instability; Non linear Optimization; Optimal Compensation; Power Factor; Power Quality; Voltage Distortion

Indexed keywords

ACTIVE FILTERS; ADAPTIVE FILTERING; CLOSED LOOP CONTROL SYSTEMS; COMPUTER SIMULATION; ELECTRIC CURRENT CONTROL; ELECTRIC LOADS; HARMONIC ANALYSIS; OPTIMAL SYSTEMS; TRANSIENTS;

EID: 1542318378     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (2)

References (6)
  • 1
    • 0025218230 scopus 로고
    • A Study of Active Power Filters Using Quad-Source PWM Converters for Harmonic Compensation
    • January
    • F. Peng, H. Akagi, and A. Nabae, "A Study of Active Power Filters Using Quad-Source PWM Converters for Harmonic Compensation," IEEE, Trans. on Power Electronics, Vol. 5, No. 1, January 1990.
    • (1990) IEEE, Trans. on Power Electronics , vol.5 , Issue.1
    • Peng, F.1    Akagi, H.2    Nabae, A.3
  • 2
    • 0030289837 scopus 로고    scopus 로고
    • New Trends in Active Filters for Line Conditioning
    • Nov./Dec.
    • H. Akagi, "New Trends in Active Filters for Line Conditioning, " IEEE, Trans. on Industry App., Vol. 32, No. 6, Nov./Dec. 1996.
    • (1996) IEEE, Trans. on Industry App. , vol.32 , Issue.6
    • Akagi, H.1
  • 3
    • 0035306571 scopus 로고    scopus 로고
    • An Optimal and Flexible Control Strategy For Active Filtering and Power Factor Correction Under Non-Sinusoidal Line Voltages
    • April
    • S.M.R. Rafiei, H.A. Toliyat, R. Ghazi, and T. Gopalarathnam, "An Optimal and Flexible Control Strategy For Active Filtering and Power Factor Correction Under Non-Sinusoidal Line Voltages," IEEE Transactions on Power Delivery, Vol. 16, No. 2, April 2001, pp 207-305.
    • (2001) IEEE Transactions on Power Delivery , vol.16 , Issue.2 , pp. 207-305
    • Rafiei, S.M.R.1    Toliyat, H.A.2    Ghazi, R.3    Gopalarathnam, T.4
  • 4
    • 0036650121 scopus 로고    scopus 로고
    • IEEE-519 Based Real Time and Optimal Control of Active Filters Under Non-Sinusoidal Line Voltages Using Neural Networks
    • July
    • S.M.R. Rafiei, R. Ghazi, and H.A. Toliyat, "IEEE-519 Based Real Time and Optimal Control of Active Filters Under Non-Sinusoidal Line Voltages Using Neural Networks," IEEE Transactions on Power Delivery, Vol. 17, No. 3, July 2002, pp 815-822.
    • (2002) IEEE Transactions on Power Delivery , vol.17 , Issue.3 , pp. 815-822
    • Rafiei, S.M.R.1    Ghazi, R.2    Toliyat, H.A.3
  • 5
    • 0003397335 scopus 로고
    • IEEE Recommended Practices and Requirements for Harmonic Control in Electric Power Systems
    • IEEE Std 519-1992, New York
    • IEEE Recommended Practices and Requirements for Harmonic Control in Electric Power Systems, IEEE std 519-1992, New York, 1993.
    • (1993) IEEE Std


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.