메뉴 건너뛰기




Volumn 4, Issue , 2003, Pages 3317-3320

Microfluidic Characterization of a Valved Glaucoma Drainage Device With Implications for Enhanced Therapeutic Efficacy

Author keywords

Fibrous Capsule; Glaucoma; Microfluidic; Microvalve; Nanopore Membrane; Valved GDD

Indexed keywords

FIBROUS CAPSULE; GLAUCOMA; MICROFLUIDIC; MICROVALVE; NANOPORE MEMBRANE; VALVED GDD;

EID: 1542270667     PISSN: 05891019     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (6)

References (10)
  • 1
    • 0014573691 scopus 로고
    • New Implant for Drainage in Glaucoma
    • A. C. Molteno, "New Implant for Drainage in Glaucoma", Br J Ophthalmol., vol. 53, no. 9, pp. 606-15, 1969.
    • (1969) Br J Ophthalmol. , vol.53 , Issue.9 , pp. 606-615
    • Molteno, A.C.1
  • 2
    • 0033795545 scopus 로고    scopus 로고
    • Ahmed Glaucoma Valve Implant vs Trabeculectomy in the Surgical Treatment of Glaucoma
    • M. R. Wilson, U. Mendis, S. D. Smith, A. Paliwal, "Ahmed Glaucoma Valve Implant vs Trabeculectomy in the Surgical Treatment of Glaucoma", Am J Ophthalmol., vol. 130, pp. 267-273, 2000.
    • (2000) Am J Ophthalmol. , vol.130 , pp. 267-273
    • Wilson, M.R.1    Mendis, U.2    Smith, S.D.3    Paliwal, A.4
  • 3
    • 0028245125 scopus 로고
    • Pathophysiology of Artificial Aqueous Drainage in Primate Eyes with Molteno Implants
    • M. J. Wilcox, D. S. Minckler, and T. E. Ogden, "Pathophysiology of Artificial Aqueous Drainage in Primate Eyes with Molteno Implants", J Glaucoma, vol. 3, no. 2, pp. 140-51, 1994.
    • (1994) J Glaucoma , vol.3 , Issue.2 , pp. 140-151
    • Wilcox, M.J.1    Minckler, D.S.2    Ogden, T.E.3
  • 4
    • 0029022776 scopus 로고
    • In Vitro and In Vivo Flow Characteristics of Glaucoma Drainage Implants
    • J. A. Prata, A. Mermoud, L. LaBree, and D. S. Minckler, "In Vitro and In Vivo Flow Characteristics of Glaucoma Drainage Implants", Ophthalmology, vol. 102, pp. 894-904, 1995.
    • (1995) Ophthalmology , vol.102 , pp. 894-904
    • Prata, J.A.1    Mermoud, A.2    LaBree, L.3    Minckler, D.S.4
  • 5
    • 0036906973 scopus 로고    scopus 로고
    • A Microfluid Test-Bed with Nanopore Membranes for In-Vitro Simulation of Flow Characteristics of Glaucoma Drainage Devices
    • Houston, TX
    • nd IEEE EMBS/BMES 2002, Houston, TX, vol. 3, pp. 1830-1831, 2002.
    • (2002) nd IEEE EMBS/BMES 2002 , vol.3 , pp. 1830-1831
    • Pan, T.1    Brown, J.D.2    Ziaie, B.3
  • 6
    • 18744388999 scopus 로고    scopus 로고
    • In Vitro Simulation of Flow Characteristics of Valved Glaucoma Drainage Devices After Fibrous Capsule Formation
    • Abstract No. 3308
    • J. D. Brown, T. Pan, B. Ziaie, "In Vitro Simulation of Flow Characteristics of Valved Glaucoma Drainage Devices After Fibrous Capsule Formation," ARVO 2003, Abstract No. 3308.
    • ARVO 2003
    • Brown, J.D.1    Pan, T.2    Ziaie, B.3
  • 7
    • 0036822706 scopus 로고    scopus 로고
    • Expectations from Clinical Trails
    • P. R. Lichter, "Expectations from Clinical Trails," Arch Ophthalmol., vol. 120, pp. 1371-1372, 2002.
    • (2002) Arch Ophthalmol. , vol.120 , pp. 1371-1372
    • Lichter, P.R.1
  • 8
    • 0004014021 scopus 로고    scopus 로고
    • Gulf Publishing Company, Houston, TX
    • th ed., Gulf Publishing Company, Houston, TX, pp. 27-37, 1998.
    • (1998) th Ed. , pp. 27-37
    • Zappe, R.W.1
  • 9
    • 0031732954 scopus 로고    scopus 로고
    • Characteristics of Glaucoma Drainage Implants during Dynamic and Steady-state Flow Conditions
    • B. A. Francis, A. Cortes, J. Chen, J. A. Alvarado, "Characteristics of Glaucoma Drainage Implants during Dynamic and Steady-state Flow Conditions", Ophthalmology, vol. 105, no. 9, pp. 1708-1714, 1997.
    • (1997) Ophthalmology , vol.105 , Issue.9 , pp. 1708-1714
    • Francis, B.A.1    Cortes, A.2    Chen, J.3    Alvarado, J.A.4
  • 10
    • 84862051140 scopus 로고    scopus 로고
    • Website: www.dowcorning.com