메뉴 건너뛰기




Volumn 155, Issue 3-4, 2005, Pages 70-74

Modern ceramic-on-ceramic bearings in total hip arthroplasty;Moderne keramik-keramik-gleitpaarung in der hüftgelenksendoprothetik

Author keywords

Bearing; Ceramic; Total hip arthroplasty

Indexed keywords

ADULT; AGED; ARTICLE; CALCIFICATION; CALCULATION; CERAMIC PROSTHESIS; DEBRIDEMENT; DEMOGRAPHY; FEMALE; FOLLOW UP; HARRIS HIP SCORE; HUMAN; INFECTION; MAJOR CLINICAL STUDY; MALE; PROSTHESIS LOOSENING; SURGICAL TECHNIQUE; TOTAL HIP PROSTHESIS; TREATMENT FAILURE; TREATMENT OUTCOME; WOUND HEALING;

EID: 15344351294     PISSN: 00435341     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10354-004-0132-6     Document Type: Article
Times cited : (4)

References (16)
  • 1
    • 0026662669 scopus 로고
    • Periprosthetic bone loss in total hip arthroplasty: Role of polyethylene wear debris and the concept of the effected joint space
    • Schmalzried TP, Jasty M, Harris WH (1992) Periprosthetic bone loss in total hip arthroplasty: role of polyethylene wear debris and the concept of the effected joint space. J Bone Joint Surg 74A: 849-863
    • (1992) J Bone Joint Surg , vol.74 A , pp. 849-863
    • Schmalzried, T.P.1    Jasty, M.2    Harris, W.H.3
  • 2
    • 0015319816 scopus 로고
    • Arthroplastic total de hanche par prosthese en alumine fritte
    • Boutin PM (1972) Arthroplastic total de hanche par prosthese en alumine fritte. Rev Chir Orthop 58: 229-246
    • (1972) Rev Chir Orthop , vol.58 , pp. 229-246
    • Boutin, P.M.1
  • 3
    • 0013912485 scopus 로고
    • Replacement of the arthritic hips by McKee-Farrar prosthesis
    • McKee GK, Watson-Farrar J (1966) Replacement of the arthritic hips by McKee-Farrar prosthesis. J Bone Joint Surg 48B: 245-259
    • (1966) J Bone Joint Surg , vol.48 B , pp. 245-259
    • McKee, G.K.1    Watson-Farrar, J.2
  • 4
    • 0037907633 scopus 로고    scopus 로고
    • Keramische gleitpaarungen in der orthopädie
    • Thomsen M, Willmann G (2003) Keramische Gleitpaarungen in der Orthopädie. Orthopäde 32: 11-16
    • (2003) Orthopäde , vol.32 , pp. 11-16
    • Thomsen, M.1    Willmann, G.2
  • 5
    • 0033779502 scopus 로고    scopus 로고
    • Modern ceramic-on-ceramic total hip systems in the United States
    • Garino JP (2000) Modern Ceramic-on-Ceramic Total Hip Systems in the United States. Clin Orthop 379: 41-47
    • (2000) Clin Orthop , vol.379 , pp. 41-47
    • Garino, J.P.1
  • 8
    • 0014525462 scopus 로고
    • Traumatic arthritis of the hip after dislocation and acetabular fractures. An end result study using a new method of result evaluation
    • Harris WH (1969) Traumatic arthritis of the hip after dislocation and acetabular fractures. An end result study using a new method of result evaluation. J Bone Joint Surg 51A: 737-755
    • (1969) J Bone Joint Surg , vol.51 A , pp. 737-755
    • Harris, W.H.1
  • 9
    • 0018687995 scopus 로고
    • Modes of failure of cemented stem type femoral components. A radiolographic analysis of loosening
    • Gruen TA, McNiece GM, Amstutz HC (1979) Modes of failure of cemented stem type femoral components. A radiolographic analysis of loosening. Clin Orthop 141: 17-23
    • (1979) Clin Orthop , vol.141 , pp. 17-23
    • Gruen, T.A.1    McNiece, G.M.2    Amstutz, H.C.3
  • 10
    • 0017047304 scopus 로고
    • Radiological demarcation of cemented sockets in total hip replacement
    • De Lee JG, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop 121: 20-32
    • (1976) Clin Orthop , vol.121 , pp. 20-32
    • De Lee, J.G.1    Charnley, J.2
  • 11
    • 0015754154 scopus 로고    scopus 로고
    • Ectopic ossification following total hip replacement. Incidence and a method of classification
    • Brooker AF, Bowerman JW, Robinson RA, et al (1998) Ectopic ossification following total hip replacement. Incidence and a method of classification. J Bone Joint Surg 55A: 1629-1632
    • (1998) J Bone Joint Surg , vol.55 A , pp. 1629-1632
    • Brooker, A.F.1    Bowerman, J.W.2    Robinson, R.A.3
  • 12
    • 0001549373 scopus 로고    scopus 로고
    • Ceramics in total hip arthroplasty: History, mechanical properties, clinical results, and current manufacturing state of the art
    • Heros RJ, Willman G (1998) Ceramics in total hip arthroplasty: history, mechanical properties, clinical results, and current manufacturing state of the art. Semin Arthroplasty 9: 114-122
    • (1998) Semin Arthroplasty , vol.9 , pp. 114-122
    • Heros, R.J.1    Willman, G.2
  • 13
    • 0007484032 scopus 로고    scopus 로고
    • Analysis of wear behaviour of alumina-alumina hip prosthesis after 10 years of implantation
    • Sedel L, Wilmann G (eds) Georg Thieme, Stuttgart
    • Prudhommeaux F, Nevelos J, Doyle C, et al (1999) Analysis of wear behaviour of alumina-alumina hip prosthesis after 10 years of implantation. In: Sedel L, Wilmann G (eds) Reliability and long-term results of ceramics in orthopaedics. Georg Thieme, Stuttgart, p 111
    • (1999) Reliability and Long-term Results of Ceramics in Orthopaedics , pp. 111
    • Prudhommeaux, F.1    Nevelos, J.2    Doyle, C.3
  • 15
    • 0031034439 scopus 로고    scopus 로고
    • Fracture of a ceramic femoral head after a revision operation: A case report
    • Pulliam IT, Trousdale RT (1997) Fracture of a ceramic femoral head after a revision operation: a case report. J Bone Joint Surg 79A: 118-121
    • (1997) J Bone Joint Surg , vol.79 A , pp. 118-121
    • Pulliam, I.T.1    Trousdale, R.T.2
  • 16
    • 0032778766 scopus 로고    scopus 로고
    • Ceramic bearing surfaces
    • Skinner HB (1999) Ceramic bearing surfaces. Clin Orthop 369: 83-91
    • (1999) Clin Orthop , vol.369 , pp. 83-91
    • Skinner, H.B.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.