메뉴 건너뛰기




Volumn 18, Issue 4, 2004, Pages 283-287

The correlation of the bispectral index with propofol effect site concentrations is not altered by epochs indicated as artefact-loaded by narcotrend

Author keywords

Artefact; Bispectral index; Narcotrend index

Indexed keywords

BIOMEDICAL ENGINEERING; PATIENT TREATMENT; PROBABILITY;

EID: 15344341695     PISSN: 13871307     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10877-005-2700-8     Document Type: Article
Times cited : (9)

References (12)
  • 1
    • 0035543938 scopus 로고    scopus 로고
    • The Narcotrend - A new EEG monitor designed to measure the depth of anaesthesia. A comparison with bispectral index monitoring during propofol-remifentanil-anaesthesia
    • Kreuer S, Biedler A, Larsen R, Schoth S, Altmann S, Wilhelm W. The Narcotrend - a new EEG monitor designed to measure the depth of anaesthesia. A comparison with bispectral index monitoring during propofol-remifentanil-anaesthesia. Anaesthesist 2001; 50: 921-925
    • (2001) Anaesthesist , vol.50 , pp. 921-925
    • Kreuer, S.1    Biedler, A.2    Larsen, R.3    Schoth, S.4    Altmann, S.5    Wilhelm, W.6
  • 2
    • 0001162205 scopus 로고
    • Cerebral states during sleep as studied by human brain potentials
    • Loomis AL, Harvey EN, Hobart CA. Cerebral states during sleep as studied by human brain potentials. J Exp Psychol 1937; 21: 127-144
    • (1937) J. Exp. Psychol. , vol.21 , pp. 127-144
    • Loomis, A.L.1    Harvey, E.N.2    Hobart, C.A.3
  • 4
    • 1342267330 scopus 로고    scopus 로고
    • Narcotrend index versus bispectral index as EEG measures of anaesthetic drug effect during propofol anesthesia
    • Kreuer S, Wilhelm W, Grundmann U, Larsen R, Bruhn J. Narcotrend index versus bispectral index as EEG measures of anaesthetic drug effect during propofol anesthesia. Anesth Analg 2004; 98: 692-697
    • (2004) Anesth. Analg. , vol.98 , pp. 692-697
    • Kreuer, S.1    Wilhelm, W.2    Grundmann, U.3    Larsen, R.4    Bruhn, J.5
  • 5
    • 0025908613 scopus 로고
    • Pharmacokinetic model driven infusion of propofol in children
    • 1:STN:280:By6A3MrptF0%3D
    • Marsh B, White M, Morton N, Kenny GN. Pharmacokinetic model driven infusion of propofol in children. Br J Anaesth 1991; 67: 41-48. 1:STN:280:By6A3MrptF0%3D
    • (1991) Br. J. Anaesth. , vol.67 , pp. 41-48
    • Marsh, B.1    White, M.2    Morton, N.3    Kenny, G.N.4
  • 7
    • 0030021080 scopus 로고    scopus 로고
    • Measuring the performance of anesthetic depth indicators
    • 10.1097/00000542-199601000-00005
    • Smith WD, Dutton RC, Smith NT. Measuring the performance of anesthetic depth indicators. Anesthesiology 1996; 84: 38-51. 10.1097/ 00000542-199601000-00005
    • (1996) Anesthesiology , vol.84 , pp. 38-51
    • Smith, W.D.1    Dutton, R.C.2    Smith, N.T.3
  • 8
    • 7844247988 scopus 로고
    • Autonomic measures as electrophysiological techniques for evaluation of the central nervous system
    • Elselvier
    • Johnson LC. Autonomic measures as electrophysiological techniques for evaluation of the central nervous system. Handbook of Electroencephalography and Clinical Neurophysiology, Vol. 8B, Elselvier, 1973: Pp. 23-42
    • (1973) Handbook of Electroencephalography and Clinical Neurophysiology , vol.8 B , pp. 23-42
    • Johnson, L.C.1
  • 9
    • 0036137528 scopus 로고    scopus 로고
    • Artefact robustness, inter- and intra-individual baseline stability, and rational EEG parameter selection
    • Bruhn J, Bouillon TW, Hoeft A, Shafer SL. Artefact robustness, inter- and intra-individual baseline stability, and rational EEG parameter selection. Anesthesiology 2002; 96: 54-59
    • (2002) Anesthesiology , vol.96 , pp. 54-59
    • Bruhn, J.1    Bouillon, T.W.2    Hoeft, A.3    Shafer, S.L.4
  • 11
    • 0032167498 scopus 로고    scopus 로고
    • Automatic artefact detection in intraoperative EEG monitoring
    • Eckert O. Automatic artefact detection in intraoperative EEG monitoring. Biomed Tech 1998; 43: 236-242
    • (1998) Biomed. Tech. , vol.43 , pp. 236-242
    • Eckert, O.1
  • 12
    • 0038110672 scopus 로고    scopus 로고
    • Narcotrend monitoring allows faster emergence and a reduction of drug consumption in propofol-remifentanil anesthesia
    • 10.1097/00000542-200307000-00009
    • Kreuer S, Biedler A, Larsen R, Altmann S, Wilhelm W. Narcotrend monitoring allows faster emergence and a reduction of drug consumption in propofol-remifentanil anesthesia. Anesthesiology 2003; 99: 34-41. 10.1097/00000542-200307000-00009
    • (2003) Anesthesiology , vol.99 , pp. 34-41
    • Kreuer, S.1    Biedler, A.2    Larsen, R.3    Altmann, S.4    Wilhelm, W.5