메뉴 건너뛰기




Volumn 30, Issue 2, 2005, Pages 300-307

The effects of implant composition on extensor tenosynovitis in a canine distal radius fracture model

Author keywords

Distal radius fractures; Titanium metallosis; plate

Indexed keywords

STAINLESS STEEL; TITANIUM;

EID: 15244341829     PISSN: 03635023     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jhsa.2004.08.004     Document Type: Article
Times cited : (19)

References (35)
  • 1
    • 0030928604 scopus 로고    scopus 로고
    • Prospective multicenter trial of a plate for dorsal fixation of distal radius fractures
    • D. Ring, J.B. Jupiter, J. Brennwald, U. Buchler, H. Hastings 2nd. Prospective multicenter trial of a plate for dorsal fixation of distal radius fractures J Hand Surg 22 1997 777 784
    • (1997) J Hand Surg , vol.22 , pp. 777-784
    • Ring, D.1    Jupiter, J.B.2    Brennwald, J.3    Buchler, U.4    Hastings II, H.5
  • 2
    • 0032460038 scopus 로고    scopus 로고
    • Complications of the AO/ASIF titanium distal radius plate system (pi plate) in internal fixation of the distal radius: A brief report
    • G.K. Kambouroglou, T.S. Axelrod Complications of the AO/ASIF titanium distal radius plate system (pi plate) in internal fixation of the distal radius a brief report J Hand Surg 23 1998 737 741
    • (1998) J Hand Surg , vol.23 , pp. 737-741
    • Kambouroglou, G.K.1    Axelrod, T.S.2
  • 3
    • 0034302091 scopus 로고    scopus 로고
    • Extensor tendon rupture secondary to the AO/ASIF titanium distal radius plate without associated plate failure: A case report
    • K.J. Lowry, B.J. Gainor, J.S. Hoskins Extensor tendon rupture secondary to the AO/ASIF titanium distal radius plate without associated plate failure a case report Am J Orthop 29 2000 789 791
    • (2000) Am J Orthop , vol.29 , pp. 789-791
    • Lowry, K.J.1    Gainor, B.J.2    Hoskins, J.S.3
  • 4
    • 0032885140 scopus 로고    scopus 로고
    • Internal fixation of distal radius fractures with dorsal dislocation: Pi-plate or two 1/4 tube plates? a prospective randomized study
    • D. Hahnloser, A. Platz, M. Amgwerd, O. Trentz Internal fixation of distal radius fractures with dorsal dislocation: pi-plate or two 1/4 tube plates? A prospective randomized study J Trauma 47 1999 760 765
    • (1999) J Trauma , vol.47 , pp. 760-765
    • Hahnloser, D.1    Platz, A.2    Amgwerd, M.3    Trentz, O.4
  • 5
    • 0034536828 scopus 로고    scopus 로고
    • Open reduction and internal fixation of intra articular and unstable fractures of the distal radius using the AO distal radius plate
    • D.A. Campbell Open reduction and internal fixation of intra articular and unstable fractures of the distal radius using the AO distal radius plate J Hand Surg 25B 2000 528 534
    • (2000) J Hand Surg , vol.25 , pp. 528-534
    • Campbell, D.A.1
  • 6
    • 0034097721 scopus 로고    scopus 로고
    • Fractures of the distal radius treated by internal fixation and early function. a prospective study of 73 consecutive patients
    • M. Jakob, D.A. Rikli, P. Regazzoni Fractures of the distal radius treated by internal fixation and early function. A prospective study of 73 consecutive patients J Bone Joint Surg 82B 2000 340 344
    • (2000) J Bone Joint Surg , vol.82 , pp. 340-344
    • Jakob, M.1    Rikli, D.A.2    Regazzoni, P.3
  • 7
    • 0025364276 scopus 로고
    • Open reduction and internal fixation of comminuted, intraarticular fractures of the distal radius
    • T.S. Axelrod, R.Y. McMurtry Open reduction and internal fixation of comminuted, intraarticular fractures of the distal radius J Hand Surg 15A 1990 1 11
    • (1990) J Hand Surg , vol.15 , pp. 1-11
    • Axelrod, T.S.1    McMurtry, R.Y.2
  • 8
    • 0032467256 scopus 로고    scopus 로고
    • Open reduction and internal fixation of unstable distal radius fractures with a low-profile plate: A multicenter study of 73 fractures
    • P.R. Carter, H.A. Frederick, G.F. Laseter Open reduction and internal fixation of unstable distal radius fractures with a low-profile plate a multicenter study of 73 fractures J Hand Surg 23A 1998 300 307
    • (1998) J Hand Surg , vol.23 , pp. 300-307
    • Carter, P.R.1    Frederick, H.A.2    Laseter, G.F.3
  • 9
    • 0141889322 scopus 로고    scopus 로고
    • Functional outcome and complications following two types of dorsal plating for unstable fractures of the distal part of the radius
    • T.D. Rozental, P.K. Beredjiklian, D.J. Bozentka Functional outcome and complications following two types of dorsal plating for unstable fractures of the distal part of the radius J Bone Joint Surg 85A 2003 1956 1960
    • (2003) J Bone Joint Surg , vol.85 , pp. 1956-1960
    • Rozental, T.D.1    Beredjiklian, P.K.2    Bozentka, D.J.3
  • 10
    • 0038722227 scopus 로고    scopus 로고
    • Dorsal plating for displaced intra-articular fractures of the distal radius
    • M. Herron, A. Faraj, M.A. Craigen Dorsal plating for displaced intra-articular fractures of the distal radius Injury 34 2003 497 502
    • (2003) Injury , vol.34 , pp. 497-502
    • Herron, M.1    Faraj, A.2    Craigen, M.A.3
  • 13
    • 0027474973 scopus 로고
    • Titanium lines: A manifestation of metallosis and tissue response to titanium alloy megaprostheses at the knee
    • D.J. Breen, D.J. Stoker Titanium lines a manifestation of metallosis and tissue response to titanium alloy megaprostheses at the knee Clin Radiol 47 1993 274 277
    • (1993) Clin Radiol , vol.47 , pp. 274-277
    • Breen, D.J.1    Stoker, D.J.2
  • 14
    • 0026641070 scopus 로고
    • Titanium wear debris in failed cemented total hip arthroplasty. An analysis of 71 cases
    • R.L. Buly, M.H. Huo, E. Salvati, W. Brien, M. Bansal Titanium wear debris in failed cemented total hip arthroplasty. An analysis of 71 cases J Arthroplasty 7 1992 315 323
    • (1992) J Arthroplasty , vol.7 , pp. 315-323
    • Buly, R.L.1    Huo, M.H.2    Salvati, E.3    Brien, W.4    Bansal, M.5
  • 15
    • 0036944038 scopus 로고    scopus 로고
    • [Iatrogenic "metalloma" (titanoma) caused by implant failure in "metal-backed" patellar joint surface replacement]
    • K. Buttner-Janz, M. Muller, K.M. Muller, J. Friemann [Iatrogenic "metalloma" (titanoma) caused by implant failure in "metal-backed" patellar joint surface replacement] Unfallchirurg 105 2002 278 282
    • (2002) Unfallchirurg , vol.105 , pp. 278-282
    • Buttner-Janz, K.1    Muller, M.2    Muller, K.M.3    Friemann, J.4
  • 17
    • 0028284421 scopus 로고
    • Cementless or hybrid total elbow arthroplasty with titanium- alloy implants. a study of interim clinical results and specific complications
    • H. Kudo, K. Iwano, J. Nishino Cementless or hybrid total elbow arthroplasty with titanium- alloy implants. A study of interim clinical results and specific complications J Arthroplasty 9 1994 269 278
    • (1994) J Arthroplasty , vol.9 , pp. 269-278
    • Kudo, H.1    Iwano, K.2    Nishino, J.3
  • 18
    • 0343851164 scopus 로고    scopus 로고
    • Extensive metallosis and necrosis in failed prostheses with cemented titanium-alloy stems and ceramic heads
    • L. Milosev, V. Antolic, A. Minovic, A. Cor, S. Herman, V. Pavlovcic Extensive metallosis and necrosis in failed prostheses with cemented titanium-alloy stems and ceramic heads J Bone Joint Surg 82B 2000 352 357
    • (2000) J Bone Joint Surg , vol.82 , pp. 352-357
    • Milosev, L.1    Antolic, V.2    Minovic, A.3    Cor, A.4    Herman, S.5    Pavlovcic, V.6
  • 20
    • 0025642529 scopus 로고
    • Cementless total joint arthroplasty, prostheses with titanium-alloy articular surfaces. a human retrieval analysis
    • S. Nasser, P.A. Campbell, D. Kilgus, N. Kossovsky, H.C. Amstutz Cementless total joint arthroplasty, prostheses with titanium-alloy articular surfaces. A human retrieval analysis Clin Orthop 261 1990 171 185
    • (1990) Clin Orthop , vol.261 , pp. 171-185
    • Nasser, S.1    Campbell, P.A.2    Kilgus, D.3    Kossovsky, N.4    Amstutz, H.C.5
  • 21
    • 0026004023 scopus 로고
    • Immunopathological response to loose cementless acetabular components
    • S. Santavirta, Y.T. Konttinen, V. Hoikka, A. Eskola Immunopathological response to loose cementless acetabular components J Bone Joint Surg 73B 1991 38 42
    • (1991) J Bone Joint Surg , vol.73 , pp. 38-42
    • Santavirta, S.1    Konttinen, Y.T.2    Hoikka, V.3    Eskola, A.4
  • 22
    • 0025874154 scopus 로고
    • Metal wear and tissue response in failed titanium alloy total hip replacements
    • J.D. Witt, M. Swann Metal wear and tissue response in failed titanium alloy total hip replacements J Bone Joint Surg 73B 1991 559 563
    • (1991) J Bone Joint Surg , vol.73 , pp. 559-563
    • Witt, J.D.1    Swann, M.2
  • 23
    • 0030991038 scopus 로고    scopus 로고
    • Tissue response to titanium plates: A transmitted electron microscopic study
    • Y.K. Kim, H.H. Yeo, S.C. Lim Tissue response to titanium plates a transmitted electron microscopic study J Oral Maxillofac Surg 55 1997 322 326
    • (1997) J Oral Maxillofac Surg , vol.55 , pp. 322-326
    • Kim, Y.K.1    Yeo, H.H.2    Lim, S.C.3
  • 24
    • 0028321408 scopus 로고
    • Particulate titanium and cobalt- chrome metallic debris in failed total knee arthroplasty. a quantitative histologic analysis
    • J.K. La Budde, J.F. Orosz, T.A. Bonfiglio, V.D. Pellegrini Jr. Particulate titanium and cobalt- chrome metallic debris in failed total knee arthroplasty. A quantitative histologic analysis J Arthroplasty 9 1994 291 304
    • (1994) J Arthroplasty , vol.9 , pp. 291-304
    • La Budde, J.K.1    Orosz, J.F.2    Bonfiglio, T.A.3    Pellegrini Jr., V.D.4
  • 25
    • 0025052402 scopus 로고
    • Macrophages stimulate bone resorption when they phagocytose particles
    • D.W. Murray, N. Rushton Macrophages stimulate bone resorption when they phagocytose particles J Bone Joint Surg 72B 1990 988 992
    • (1990) J Bone Joint Surg , vol.72 , pp. 988-992
    • Murray, D.W.1    Rushton, N.2
  • 26
    • 0014063691 scopus 로고
    • Tissue reaction in rabbit muscle exposed to metallic implants
    • P.G. Laing, A.B. Ferguson Jr, E.S. Hodge Tissue reaction in rabbit muscle exposed to metallic implants J Biomed Mater Res 1 1967 135 149
    • (1967) J Biomed Mater Res , vol.1 , pp. 135-149
    • Laing, P.G.1    Ferguson Jr., A.B.2    Hodge, E.S.3
  • 28
    • 0036068485 scopus 로고    scopus 로고
    • Failure of a retinacular flap to prevent dorsal wrist pain after titanium Pi plate fixation of distal radius fractures
    • P.P. Chiang, S. Roach, M.E. Baratz Failure of a retinacular flap to prevent dorsal wrist pain after titanium Pi plate fixation of distal radius fractures J Hand Surg 27A 2002 724 728
    • (2002) J Hand Surg , vol.27 , pp. 724-728
    • Chiang, P.P.1    Roach, S.2    Baratz, M.E.3
  • 29
    • 0034068196 scopus 로고    scopus 로고
    • Extensor tendon rupture after internal fixation of a distal radius fracture using a dorsally placed AO/ASIF titanium pi plate. Arbeitsgemeinschaft fur Osteosynthesefragen/Association for the Study of Internal Fixation
    • D.P. Schnur, B. Chang Extensor tendon rupture after internal fixation of a distal radius fracture using a dorsally placed AO/ASIF titanium pi plate. Arbeitsgemeinschaft fur Osteosynthesefragen/Association for the Study of Internal Fixation Ann Plast Surg 44 2000 564 566
    • (2000) Ann Plast Surg , vol.44 , pp. 564-566
    • Schnur, D.P.1    Chang, B.2
  • 30
    • 0015683182 scopus 로고
    • Changes in nonosseous tissue adjacent to titanium implants
    • G. Meachim, D.F. Williams Changes in nonosseous tissue adjacent to titanium implants J Biomed Mater Res 7 1973 555 572
    • (1973) J Biomed Mater Res , vol.7 , pp. 555-572
    • Meachim, G.1    Williams, D.F.2
  • 31
    • 0020199476 scopus 로고
    • Alloys for orthopaedic implant use
    • H.S. Dobbs, J.L. Robertson Alloys for orthopaedic implant use Eng Med 11 1982 175 182
    • (1982) Eng Med , vol.11 , pp. 175-182
    • Dobbs, H.S.1    Robertson, J.L.2
  • 32
    • 0025514172 scopus 로고
    • The effects of bulk versus particulate titanium and cobalt chrome alloy implanted into the rabbit tibia
    • S.B. Goodman, V.L. Fornasier, J. Lee, J. Kei The effects of bulk versus particulate titanium and cobalt chrome alloy implanted into the rabbit tibia J Biomed Mater Res 24 1990 1539 1549
    • (1990) J Biomed Mater Res , vol.24 , pp. 1539-1549
    • Goodman, S.B.1    Fornasier, V.L.2    Lee, J.3    Kei, J.4
  • 34
    • 0031951657 scopus 로고    scopus 로고
    • Rupture of flexor pollicis longus tendon: A complication of volar plating of the distal radius
    • J.S. Bell, R. Wollstein, N.D. Citron Rupture of flexor pollicis longus tendon a complication of volar plating of the distal radius J Bone Joint Surg 80B 1998 225 226
    • (1998) J Bone Joint Surg , vol.80 , pp. 225-226
    • Bell, J.S.1    Wollstein, R.2    Citron, N.D.3
  • 35
    • 0032720912 scopus 로고    scopus 로고
    • Delayed rupture of the flexor pollicis longus tendon after inappropriate placement of the pi plate on the volar surface of the distal radius
    • J.A. Nunley, P.R. Rowan Delayed rupture of the flexor pollicis longus tendon after inappropriate placement of the pi plate on the volar surface of the distal radius J Hand Surg 24A 1999 1279 1280
    • (1999) J Hand Surg , vol.24 , pp. 1279-1280
    • Nunley, J.A.1    Rowan, P.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.