메뉴 건너뛰기




Volumn 243, Issue 2, 2005, Pages 178-181

Foreign body granulomas secondary to retained sponge fragment following mitomycin C trabeculectomy

Author keywords

[No Author keywords available]

Indexed keywords

GENTAMICIN; MITOMYCIN C; VANCOMYCIN;

EID: 14944363304     PISSN: 0721832X     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00417-004-1011-y     Document Type: Article
Times cited : (16)

References (7)
  • 1
    • 0036127424 scopus 로고    scopus 로고
    • Incidence of late onset bleb related complications following trabeculectomy with mitomycin
    • 1:CAS:528:DC%2BD38Xitlyqtb4%3D
    • DeBry P, Perkins TW, Heatley G, Kaufman P, Brumback LC (2002) Incidence of late onset bleb related complications following trabeculectomy with mitomycin. Arch Ophthalmol 120:297-300 1:CAS:528:DC%2BD38Xitlyqtb4%3D
    • (2002) Arch. Ophthalmol. , vol.120 , pp. 297-300
    • DeBry, P.1    Perkins, T.W.2    Heatley, G.3    Kaufman, P.4    Brumback, L.C.5
  • 2
    • 0031916590 scopus 로고    scopus 로고
    • Late-onset bleb leaks glaucoma filtering surgery
    • 1:STN:280:DyaK1c3isVOisw%3D%3D
    • Greenfield DS, Liebmann JM, Jee J, Ritch R (1998) Late-onset bleb leaks glaucoma filtering surgery. Arch Ophthalmol 116(4):443-447 1:STN:280:DyaK1c3isVOisw%3D%3D
    • (1998) Arch. Ophthalmol. , vol.116 , Issue.4 , pp. 443-447
    • Greenfield, D.S.1    Liebmann, J.M.2    Jee, J.3    Ritch, R.4
  • 3
    • 18144453999 scopus 로고    scopus 로고
    • Is cellulose sponge degradable or stable as an implant material?
    • 10.1016/S0142-9612(99)00094-0
    • Martson M, Viljanto J, Hurme T (1999) Is cellulose sponge degradable or stable as an implant material? Biomaterials 20:1989-1995 10.1016/ S0142-9612(99)00094-0
    • (1999) Biomaterials , vol.20 , pp. 1989-1995
    • Martson, M.1    Viljanto, J.2    Hurme, T.3
  • 5
    • 0036896445 scopus 로고    scopus 로고
    • Microscopic fragmentation of ophthalmic surgical sponge spears used for delivery of antiproliferative agents in glaucoma filtering surgery
    • 10.1136/bjo.86.12.1448
    • Poole TRG, Gillespie IH, Knee G, Hitworth J (2002) Microscopic fragmentation of ophthalmic surgical sponge spears used for delivery of antiproliferative agents in glaucoma filtering surgery. Br J Ophthalmol 86:1448-1449 10.1136/bjo.86.12.1448
    • (2002) Br. J. Ophthalmol. , vol.86 , pp. 1448-1449
    • Poole, T.R.G.1    Gillespie, I.H.2    Knee, G.3    Hitworth, J.4
  • 6
    • 0028307505 scopus 로고
    • Retained cellulose sponge after trabeculectomy with adjunctive subconjunctival mitomycin C
    • 1:STN:280:ByuB1MrmtVM%3D
    • Shin DH, Tsai CS, Kupin TH, Olivier M (1994) Retained cellulose sponge after trabeculectomy with adjunctive subconjunctival mitomycin C. Am J Ophthalmol 118:111-112 1:STN:280:ByuB1MrmtVM%3D
    • (1994) Am. J. Ophthalmol. , vol.118 , pp. 111-112
    • Shin, D.H.1    Tsai, C.S.2    Kupin, T.H.3    Olivier, M.4
  • 7
    • 0017365623 scopus 로고
    • Cellulose granulomas and their relationship to intestinal obstruction
    • 10.1016/0002-9610(77)90207-0
    • Tinker MA, Teicher I, Burdman D (1977) Cellulose granulomas and their relationship to intestinal obstruction. Am J Surg 133:134-139 10.1016/ 0002-9610(77)90207-0
    • (1977) Am. J. Surg. , vol.133 , pp. 134-139
    • Tinker, M.A.1    Teicher, I.2    Burdman, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.