메뉴 건너뛰기




Volumn 13, Issue 8, 2005, Pages 1071-1078

Accommodation of multi-leak location in a pipeline

Author keywords

Leak detection; Model based approach for fault detection and isolation; Robust observer; Updating residual generator

Indexed keywords

ALGORITHMS; COMPUTER SIMULATION; DUCTS; ERROR ANALYSIS; FLUID DYNAMICS; LEAKAGE (FLUID); MATHEMATICAL MODELS; PRESSURE EFFECTS; SENSORS;

EID: 14944354567     PISSN: 09670661     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.conengprac.2004.09.010     Document Type: Article
Times cited : (74)

References (16)
  • 1
    • 0023345971 scopus 로고
    • Leak detection methods for pipelines
    • L. Billman R. Isermann Leak detection methods for pipelines Automatica 23 3 1987 381-385
    • (1987) Automatica , vol.23 , Issue.3 , pp. 381-385
    • Billman, L.1    Isermann, R.2
  • 8
    • 0004178386 scopus 로고    scopus 로고
    • Englewood Cliffs, NJ: Prentice-Hall
    • H. Khalil Nonlinear systems 2002 Prentice-Hall Englewood Cliffs, NJ
    • (2002) Nonlinear Systems
    • Khalil, H.1
  • 9
    • 0000038479 scopus 로고    scopus 로고
    • Leak detection and isolation for transmission pipelines via nonlinear state estimation
    • Kowalczuk, Z., Gunawickrama, K. (2000). Leak detection and isolation for transmission pipelines via nonlinear state estimation, In 4th IFAC SAFEPROCESS, vol. 2 (pp. 943-948).
    • (2000) 4th IFAC SAFEPROCESS , vol.2 , pp. 943-948
    • Kowalczuk, Z.1    Gunawickrama, K.2
  • 10
    • 14944374892 scopus 로고    scopus 로고
    • Sistema detector de fugas en una tuberia con transferencia de calor
    • Nov., México
    • Pascual, S., Verde, C., & Casasola, V. (2003). Sistema detector de fugas en una tuberia con transferencia de calor, In Congreso de Ductos PEMEX, Puebla, Nov., México.
    • (2003) Congreso de Ductos PEMEX Puebla,
    • Pascual, S.1    Verde, C.2    Casasola, V.3
  • 11
    • 0035281423 scopus 로고    scopus 로고
    • Design of nonlinear observers for detecting faults in hydraulic sub-sea pipelines
    • D. Shields S. Ashton S. Daley Design of nonlinear observers for detecting faults in hydraulic sub-sea pipelines Control Engineering Practice 9 2001 297-311
    • (2001) Control Engineering Practice , vol.9 , pp. 297-311
    • Shields, D.1    Ashton, S.2    Daley, S.3
  • 12
    • 0035366175 scopus 로고    scopus 로고
    • Multi-leak detection and isolation in fluid pipelines
    • C. Verde Multi-leak detection and isolation in fluid pipelines Control Engineering Practice 9 2001 673-682
    • (2001) Control Engineering Practice , vol.9 , pp. 673-682
    • Verde, C.1
  • 14
    • 12344310103 scopus 로고    scopus 로고
    • Leak isolation conditions in a pipeline via a geometric approach
    • IFAC, Washington DC
    • Visairo, N., & Verde, C. (2003). Leak isolation conditions in a pipeline via a geometric approach. In Safeprocess03, IFAC, Washington DC (pp. 1023-1028).
    • (2003) Safeprocess03 , pp. 1023-1028
    • Visairo, N.1    Verde, C.2
  • 16
    • 0036530317 scopus 로고    scopus 로고
    • A robust detection and isolation scheme for abrupt and incipient faults in nonlinear systems
    • X. Zhang M. Polycarpou T. Parisini A robust detection and isolation scheme for abrupt and incipient faults in nonlinear systems IEEE Transactions on Automatic Control 47 4 2002 576-592
    • (2002) IEEE Transactions on Automatic Control , vol.47 , Issue.4 , pp. 576-592
    • Zhang, X.1    Polycarpou, M.2    Parisini, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.