메뉴 건너뛰기




Volumn 23, Issue 4, 2004, Pages 528-532

Application of a glass fiber-reinforced composite material to clasps - The effects of immersion and repeated loading

Author keywords

Clasp; Glass fiber reinforced composite; Mechanical property

Indexed keywords

GLASS FIBER;

EID: 14844343281     PISSN: 02874547     EISSN: None     Source Type: Journal    
DOI: 10.4012/dmj.23.528     Document Type: Article
Times cited : (10)

References (12)
  • 1
    • 14844352830 scopus 로고    scopus 로고
    • Structural investigation of "Targis/Vectris"
    • Yoshinari M, Kataoka S. Structural investigation of "Targis/ Vectris". Quintessence Dent Technol 1997; extra number: 84-92.
    • (1997) Quintessence Dent Technol , vol.EXTRA NUMBER , pp. 84-92
    • Yoshinari, M.1    Kataoka, S.2
  • 4
    • 0036716071 scopus 로고    scopus 로고
    • Dynamic viscoelastic properties of commercial glass fiber-reinforced resin used for crowns and bridges
    • Fujii K, Arikawa H, Kanie T, Hamano T, Nishi Y, Nagaoka E. Dynamic viscoelastic properties of commercial glass fiber-reinforced resin used for crowns and bridges. J Oral Rehabil 2002; 29: 827-834.
    • (2002) J Oral Rehabil , vol.29 , pp. 827-834
    • Fujii, K.1    Arikawa, H.2    Kanie, T.3    Hamano, T.4    Nishi, Y.5    Nagaoka, E.6
  • 6
    • 14844342312 scopus 로고
    • Experimental studies on retention of cast clasp - Gingivally approaching clasp (I-bar type)
    • Nishiyama A. Experimental studies on retention of cast clasp - Gingivally approaching clasp (I-bar type). J Jpn Prosthodont Soc 1976; 20: 43-62.
    • (1976) J Jpn Prosthodont Soc , vol.20 , pp. 43-62
    • Nishiyama, A.1
  • 7
    • 84998204939 scopus 로고
    • The permanent deformation of cast clasp
    • Hattori M. The permanent deformation of cast clasp. J Jpn Prosthodont Soc 1976; 20: 134-150.
    • (1976) J Jpn Prosthodont Soc , vol.20 , pp. 134-150
    • Hattori, M.1
  • 8
    • 0019273760 scopus 로고
    • Study of retention in attachment for overdenture. Part I. Laboratory-made stud attachment
    • Nagaoka E. Study of retention in attachment for overdenture. Part I. Laboratory-made stud attachment. J Osaka Univ Dent Sch 1980; 20: 201-214.
    • (1980) J Osaka Univ Dent Sch , vol.20 , pp. 201-214
    • Nagaoka, E.1
  • 10
    • 0347654682 scopus 로고
    • Retention of cobalt-chromium partial dentures
    • Bates JF. Retention of cobalt-chromium partial dentures. Dent Pract 1963; 14: 168-171.
    • (1963) Dent Pract , vol.14 , pp. 168-171
    • Bates, J.F.1
  • 11
    • 0019541955 scopus 로고
    • A study of the flexibility of wrought wires clasps
    • Frank RP, Nicholls JI. A study of the flexibility of wrought wires clasps. J Prosthet Dent 1981; 45: 259-267.
    • (1981) J Prosthet Dent , vol.45 , pp. 259-267
    • Frank, R.P.1    Nicholls, J.I.2
  • 12
    • 14844357728 scopus 로고
    • Mechanical studies on cast clasps - Influence of factors on mechanical behavior and retention
    • Yamaga T. Mechanical studies on cast clasps - Influence of factors on mechanical behavior and retention. J Jpn Prosthodont Soc 1979; 23: 271-287.
    • (1979) J Jpn Prosthodont Soc , vol.23 , pp. 271-287
    • Yamaga, T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.