메뉴 건너뛰기




Volumn 45, Issue 6, 2005, Pages 896-900

Clinical study of interference with cardiac pacemakers by a magnetic field at power line frequencies

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ALGORITHM; ARTICLE; CONTROLLED STUDY; DENSITY; ELECTRIC FIELD; ELECTROCARDIOGRAPHY; ELECTROMAGNETIC FIELD; ENERGY; FEMALE; HUMAN; MAGNETIC FIELD; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; SINUS NODE;

EID: 14844331752     PISSN: 07351097     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jacc.2004.10.072     Document Type: Article
Times cited : (56)

References (7)
  • 2
    • 0034777612 scopus 로고    scopus 로고
    • The interference threshold of unipolar cardiac pacemakers in extremely low frequency magnetic fields
    • A. Scholten, J. Silny The interference threshold of unipolar cardiac pacemakers in extremely low frequency magnetic fields J Med Engl Technol 25 2001 185 194
    • (2001) J Med Engl Technol , vol.25 , pp. 185-194
    • Scholten, A.1    Silny, J.2
  • 3
    • 0026316643 scopus 로고
    • The influence of elevated 50 Hz electric and magnetic fields on implanted cardiac pacemakers: The role of the lead configuration and programming of the sensitivity
    • L. Toinoven, J. Valjus, M. Hongisto, R. Metso The influence of elevated 50 Hz electric and magnetic fields on implanted cardiac pacemakers: the role of the lead configuration and programming of the sensitivity Pacing Clin Electrophysiol 14 1991 2114 2122
    • (1991) Pacing Clin Electrophysiol , vol.14 , pp. 2114-2122
    • Toinoven, L.1    Valjus, J.2    Hongisto, M.3    Metso, R.4
  • 4
    • 85030813696 scopus 로고    scopus 로고
    • Journal officiel des Communautés Européennes, L199/59, July 30, 1999
    • Journal officiel des Communautés Européennes, L199/59, July 30, 1999 http://europa.eu.int/eur-lex/fr/search/search_oj.html Accessed August 22, 2004
  • 5
    • 0036741233 scopus 로고    scopus 로고
    • Interference in implanted cardiac devices: Part I
    • S.L. Pinski, R.G. Trohman Interference in implanted cardiac devices: part I Pacing Clin Electrophysiol 25 2002 1367 1381
    • (2002) Pacing Clin Electrophysiol , vol.25 , pp. 1367-1381
    • Pinski, S.L.1    Trohman, R.G.2
  • 6
    • 0038523779 scopus 로고    scopus 로고
    • Effects of 50 to 60 Hz and of 20 to 50 kHz magnetic fields on the operation of implanted cardiac pacemakers
    • R. Frank, M. Souques, C. Himbert Effects of 50 to 60 Hz and of 20 to 50 kHz magnetic fields on the operation of implanted cardiac pacemakers Arch Mal Coeur 96 2003 35 41
    • (2003) Arch Mal Coeur , vol.96 , pp. 35-41
    • Frank, R.1    Souques, M.2    Himbert, C.3
  • 7
    • 0036693687 scopus 로고    scopus 로고
    • Electronic security systems and active implantable medical devices
    • W. Irnich Electronic security systems and active implantable medical devices Pacing Clin Electrophysiol 25 2002 1235 1258
    • (2002) Pacing Clin Electrophysiol , vol.25 , pp. 1235-1258
    • Irnich, W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.