2
-
-
0007934664
-
Hydrophobicity of composite insulators: Measurement and influence on flashover performance
-
Stockholm
-
Kartings R.: "Hydrophobicity of composite insulators: measurement and influence on flashover performance", International Symposium on Electric Power Engineering, Stockholm, 1995.
-
(1995)
International Symposium on Electric Power Engineering
-
-
Kartings, R.1
-
3
-
-
14844328261
-
Set up of a method to evaluate the surface hydrophobicity of insulators
-
Yokohama
-
Pigini A., Tomba A.: "Set up of a method to evaluate the surface hydrophobicity of insulators", ISH 1993, Yokohama.
-
ISH 1993
-
-
Pigini, A.1
Tomba, A.2
-
4
-
-
14844305114
-
Diagnostic testing of composite insulators used on series compensation platforms in Hydro-Québec
-
Villancourt G. H. and y Bilodeau P.: "Diagnostic testing of composite insulators used on series compensation platforms in Hydro-Québec", ISH 1999.
-
ISH 1999
-
-
Villancourt, G.H.1
Bilodeau, P.2
-
5
-
-
0013180176
-
Diagnostic methods of non-ceramic insulators for H.V. lines
-
Nigris M., Tavano F., Zagliani F., Rendina R.: "Diagnostic methods of non-ceramic insulators for H.V. lines", CIGRE Session 2000, 22-207.
-
CIGRE Session 2000
, pp. 22-207
-
-
Nigris, M.1
Tavano, F.2
Zagliani, F.3
Rendina, R.4
-
6
-
-
14844318261
-
Daylight corona discharge imager
-
Linders M., Elstein S., Linders P., Topaz J.M. and Phillips A.J.: "Daylight corona discharge imager", ISH 1999, Page 439.
-
ISH 1999
, pp. 439
-
-
Linders, M.1
Elstein, S.2
Linders, P.3
Topaz, J.M.4
Phillips, A.J.5
-
7
-
-
0030125975
-
Outdoor leakage current monitoring of silicone composite insulators in coastal service conditions
-
April
-
Vlastós A. E., Orbeck T.: "Outdoor leakage current monitoring of silicone composite insulators in coastal service conditions", IEEE Trans. On Power Delivery, Vol. 11, No. 2, April 1996.
-
(1996)
IEEE Trans. on Power Delivery
, vol.11
, Issue.2
-
-
Vlastós, A.E.1
Orbeck, T.2
-
8
-
-
0030283705
-
On-line leakage current monitoring of 400 kV insulator strings in polluted areas
-
Nov.
-
Fierro-Chávez, J.L., Ramírez-Vázquez I. and Montoya-Tena, G.: "On-line leakage current monitoring of 400 kV insulator strings in polluted areas". IEE Proc.-Generation, Transmission and Distribution, Vol. 143, No. 6, Nov. 1996.
-
(1996)
IEE Proc.-generation, Transmission and Distribution
, vol.143
, Issue.6
-
-
Fierro-Chávez, J.L.1
Ramírez-Vázquez, I.2
Montoya-Tena, G.3
-
9
-
-
0036647403
-
Nonstandard method for accelerated ageing tests of nonceramic insulators
-
July
-
I.R. Vazquez, G. M. Tena and R.H. Corona, "Nonstandard method for accelerated ageing tests of nonceramic insulators", IEE Proceedings - Generation, Transmission and Distribution, Vol. 149, N. 4, July 2002.
-
(2002)
IEE Proceedings - Generation, Transmission and Distribution
, vol.149
, Issue.4
-
-
Vazquez, I.R.1
Tena, G.M.2
Corona, R.H.3
-
10
-
-
84904812063
-
Experience with two faulty composite insulators detection methods in Hydro-Quebec
-
Villancourt G.H.: "Experience with two faulty composite insulators detection methods in Hydro-Quebec", ISH 1997.
-
ISH 1997
-
-
Villancourt, G.H.1
-
11
-
-
14844332371
-
The influence of water and pollution on diagnosing defective composite insulator by electric field mapping
-
Yang Chun Chen, Cheng Rong Li, Xidong Liang, Shaowu Wang, "The influence of water and pollution on diagnosing defective composite insulator by electric field mapping", ISH 1999.
-
ISH 1999
-
-
Yang Chun Chen1
Cheng Rong Li2
Liang, X.3
Wang, S.4
|