메뉴 건너뛰기




Volumn , Issue , 2004, Pages 471-474

Diagnostic of non-ceramic insulators aged in a salt fog chamber by using electric field sensor

Author keywords

[No Author keywords available]

Indexed keywords

ELECTRIC CONDUCTORS; ELECTRIC FIELD MEASUREMENT; FLASHOVER; HYDROPHOBICITY; LEAKAGE CURRENTS; SENSORS;

EID: 14844323659     PISSN: 01642006     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (18)

References (11)
  • 2
    • 0007934664 scopus 로고
    • Hydrophobicity of composite insulators: Measurement and influence on flashover performance
    • Stockholm
    • Kartings R.: "Hydrophobicity of composite insulators: measurement and influence on flashover performance", International Symposium on Electric Power Engineering, Stockholm, 1995.
    • (1995) International Symposium on Electric Power Engineering
    • Kartings, R.1
  • 3
    • 14844328261 scopus 로고    scopus 로고
    • Set up of a method to evaluate the surface hydrophobicity of insulators
    • Yokohama
    • Pigini A., Tomba A.: "Set up of a method to evaluate the surface hydrophobicity of insulators", ISH 1993, Yokohama.
    • ISH 1993
    • Pigini, A.1    Tomba, A.2
  • 4
    • 14844305114 scopus 로고    scopus 로고
    • Diagnostic testing of composite insulators used on series compensation platforms in Hydro-Québec
    • Villancourt G. H. and y Bilodeau P.: "Diagnostic testing of composite insulators used on series compensation platforms in Hydro-Québec", ISH 1999.
    • ISH 1999
    • Villancourt, G.H.1    Bilodeau, P.2
  • 7
    • 0030125975 scopus 로고    scopus 로고
    • Outdoor leakage current monitoring of silicone composite insulators in coastal service conditions
    • April
    • Vlastós A. E., Orbeck T.: "Outdoor leakage current monitoring of silicone composite insulators in coastal service conditions", IEEE Trans. On Power Delivery, Vol. 11, No. 2, April 1996.
    • (1996) IEEE Trans. on Power Delivery , vol.11 , Issue.2
    • Vlastós, A.E.1    Orbeck, T.2
  • 10
    • 84904812063 scopus 로고    scopus 로고
    • Experience with two faulty composite insulators detection methods in Hydro-Quebec
    • Villancourt G.H.: "Experience with two faulty composite insulators detection methods in Hydro-Quebec", ISH 1997.
    • ISH 1997
    • Villancourt, G.H.1
  • 11
    • 14844332371 scopus 로고    scopus 로고
    • The influence of water and pollution on diagnosing defective composite insulator by electric field mapping
    • Yang Chun Chen, Cheng Rong Li, Xidong Liang, Shaowu Wang, "The influence of water and pollution on diagnosing defective composite insulator by electric field mapping", ISH 1999.
    • ISH 1999
    • Yang Chun Chen1    Cheng Rong Li2    Liang, X.3    Wang, S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.