메뉴 건너뛰기




Volumn 15, Issue 3, 2005, Pages 323-331

Intra-rater reliability of electromyographic recordings and subjective evaluation of neck muscle fatigue among helicopter pilots

Author keywords

Borg scale; EMG; ICC; Measurement error; Repeatability

Indexed keywords

AIRPLANE PILOT; ARTICLE; CALCULATION; CONTROLLED STUDY; CORRELATION ANALYSIS; ELECTROMYOGRAPHY; ERROR; EVALUATION; FREQUENCY MODULATION; HELICOPTER; HUMAN; HUMAN EXPERIMENT; MALE; MUSCLE FATIGUE; MUSCLE FORCE; MUSCLE ISOMETRIC CONTRACTION; MUSCLE STRENGTH; NECK MUSCLE; NORMAL HUMAN; PERCEPTION; PRIORITY JOURNAL; RATING SCALE; RELIABILITY; SITTING; STATISTICAL ANALYSIS; TASK PERFORMANCE;

EID: 14844322212     PISSN: 10506411     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jelekin.2004.11.001     Document Type: Article
Times cited : (22)

References (40)
  • 3
    • 0013941871 scopus 로고
    • The intraclass correlation coefficient as a measure of reliability
    • J.J. Bartko The intraclass correlation coefficient as a measure of reliability Psychol. Rep. 19 1966 3 11
    • (1966) Psychol. Rep. , vol.19 , pp. 3-11
    • Bartko, J.J.1
  • 5
    • 0029083055 scopus 로고
    • Surface electrodes are not appropriate to record selective myoelectric activity of splenius capitis muscle in humans
    • M.A. Benhamou, M. Revel, and C. Vallee Surface electrodes are not appropriate to record selective myoelectric activity of splenius capitis muscle in humans Exp. Brain Res. 105 1995 432 438
    • (1995) Exp. Brain Res. , vol.105 , pp. 432-438
    • Benhamou, M.A.1    Revel, M.2    Vallee, C.3
  • 6
    • 0030596840 scopus 로고    scopus 로고
    • Measurement error
    • J.M. Bland, and D.G. Altman Measurement error BMJ 313 1996 744 746
    • (1996) BMJ , vol.313 , pp. 744-746
    • Bland, J.M.1    Altman, D.G.2
  • 7
    • 0020410785 scopus 로고
    • Psychophysical bases of perceived exertion
    • G.A. Borg Psychophysical bases of perceived exertion Med. Sci. Sports Exerc. 14 1982 377 381
    • (1982) Med. Sci. Sports Exerc. , vol.14 , pp. 377-381
    • Borg, G.A.1
  • 9
    • 0034101601 scopus 로고    scopus 로고
    • Between-days reliability of subjective and objective assessments of back extensor muscle fatigue in subjects without lower-back pain
    • A. Dedering, M. Roos af Hjelmsäter, B. Elfving, K. Harms-Ringdahl, and G. Nemeth Between-days reliability of subjective and objective assessments of back extensor muscle fatigue in subjects without lower-back pain J. Electromyogr. Kinesiol. 10 2000 151 158
    • (2000) J. Electromyogr. Kinesiol. , vol.10 , pp. 151-158
    • Dedering, A.1    Roos Af Hjelmsäter, M.2    Elfving, B.3    Harms-Ringdahl, K.4    Nemeth, G.5
  • 10
    • 0036018130 scopus 로고    scopus 로고
    • Influence of interelectrode distance and force level on the spectral parameters of surface electromyographic recordings from the lumbar muscles
    • B. Elfving, D. Liljequist, E. Mattsson, and G. Nemeth Influence of interelectrode distance and force level on the spectral parameters of surface electromyographic recordings from the lumbar muscles J. Electromyogr. Kinesiol. 12 2002 295 304
    • (2002) J. Electromyogr. Kinesiol. , vol.12 , pp. 295-304
    • Elfving, B.1    Liljequist, D.2    Mattsson, E.3    Nemeth, G.4
  • 11
    • 0345086420 scopus 로고    scopus 로고
    • Reliability of EMG spectral parameters in repeated measurements of back muscle fatigue
    • B. Elfving, G. Nemeth, I. Arvidsson, and M. Lamontagne Reliability of EMG spectral parameters in repeated measurements of back muscle fatigue J. Electromyogr. Kinesiol. 9 1999 235 243
    • (1999) J. Electromyogr. Kinesiol. , vol.9 , pp. 235-243
    • Elfving, B.1    Nemeth, G.2    Arvidsson, I.3    Lamontagne, M.4
  • 12
    • 0036153336 scopus 로고    scopus 로고
    • Location of innervation zones of sternocleidomastoid and scalene muscles - A basis for clinical and research electromyography applications
    • D. Falla, P. Dall'Alba, A. Rainoldi, R. Merletti, and G. Jull Location of innervation zones of sternocleidomastoid and scalene muscles - a basis for clinical and research electromyography applications Clin. Neurophysiol. 113 2002 57 63
    • (2002) Clin. Neurophysiol. , vol.113 , pp. 57-63
    • Falla, D.1    Dall'Alba, P.2    Rainoldi, A.3    Merletti, R.4    Jull, G.5
  • 13
    • 0036942611 scopus 로고    scopus 로고
    • Repeatability of surface EMG variables in the sternocleidomastoid and anterior scalene muscles
    • D. Falla, P. Dall'Alba, A. Rainoldi, R. Merletti, and G. Jull Repeatability of surface EMG variables in the sternocleidomastoid and anterior scalene muscles Eur. J. Appl. Physiol. 87 2002 542 549
    • (2002) Eur. J. Appl. Physiol. , vol.87 , pp. 542-549
    • Falla, D.1    Dall'Alba, P.2    Rainoldi, A.3    Merletti, R.4    Jull, G.5
  • 14
    • 0038702342 scopus 로고    scopus 로고
    • Myoelectric manifestations of sternocleidomastoid and anterior scalene muscle fatigue in chronic neck pain patients
    • D. Falla, A. Rainoldi, R. Merletti, and G. Jull Myoelectric manifestations of sternocleidomastoid and anterior scalene muscle fatigue in chronic neck pain patients Clin. Neurophysiol. 114 2003 488 495
    • (2003) Clin. Neurophysiol. , vol.114 , pp. 488-495
    • Falla, D.1    Rainoldi, A.2    Merletti, R.3    Jull, G.4
  • 15
    • 0025217902 scopus 로고
    • Median frequency of the myoelectric signal in cervical paraspinal muscles
    • P. Gogia, and M. Sabbahi Median frequency of the myoelectric signal in cervical paraspinal muscles Arch. Phys. Med. Rehabil. 71 1990 408 414
    • (1990) Arch. Phys. Med. Rehabil. , vol.71 , pp. 408-414
    • Gogia, P.1    Sabbahi, M.2
  • 16
    • 0025950617 scopus 로고
    • Changes in fatigue characteristics of cervical paraspinal muscles with posture
    • P. Gogia, and M. Sabbahi Changes in fatigue characteristics of cervical paraspinal muscles with posture Spine 16 1991 1135 1140
    • (1991) Spine , vol.16 , pp. 1135-1140
    • Gogia, P.1    Sabbahi, M.2
  • 17
    • 0028300028 scopus 로고
    • Electromyographic analysis of neck muscle fatigue in patients with osteoarthritis of the cervical spine
    • P.P. Gogia, and M.A. Sabbahi Electromyographic analysis of neck muscle fatigue in patients with osteoarthritis of the cervical spine Spine 19 1994 502 506
    • (1994) Spine , vol.19 , pp. 502-506
    • Gogia, P.P.1    Sabbahi, M.A.2
  • 18
    • 0032526591 scopus 로고    scopus 로고
    • Morphometry of human neck muscles
    • L.K. Kamibayashi, and F.J.R. Richmond Morphometry of human neck muscles Spine 23 1998 1314 1323
    • (1998) Spine , vol.23 , pp. 1314-1323
    • Kamibayashi, L.K.1    Richmond, F.J.R.2
  • 19
    • 0030807263 scopus 로고    scopus 로고
    • Lumbar paraspinal muscle fatigability in repetitive isoinertial loading: EMG spectral indices, Borg scale and endurance time
    • M. Kankaanpää, S. Taimela, C.L. Webber Jr., O. Airaksinen, and O. Hänninen Lumbar paraspinal muscle fatigability in repetitive isoinertial loading: EMG spectral indices, Borg scale and endurance time Eur. J. Appl. Physiol. 76 1997 236 242
    • (1997) Eur. J. Appl. Physiol. , vol.76 , pp. 236-242
    • Kankaanpää, M.1    Taimela, S.2    Webber Jr., C.L.3    Airaksinen, O.4    Hänninen, O.5
  • 20
    • 0035119048 scopus 로고    scopus 로고
    • Paraspinal muscle EMG fatigue testing with two methods in healthy volunteers. Reliability in the context of clinical applications
    • G.A. Koumantakis, F. Arnall, R.G. Cooper, and J.A. Oldham Paraspinal muscle EMG fatigue testing with two methods in healthy volunteers. Reliability in the context of clinical applications Clin. Biomech. (Bristol, Avon) 16 2001 263 266
    • (2001) Clin. Biomech. (Bristol, Avon) , vol.16 , pp. 263-266
    • Koumantakis, G.A.1    Arnall, F.2    Cooper, R.G.3    Oldham, J.A.4
  • 21
    • 0036221820 scopus 로고    scopus 로고
    • Evaluation of measurement strategies to increase the reliability of EMG indices to assess back muscle fatigue and recovery
    • C. Larevière, A.B. Arsenault, D. Gravel, D. Gagnon, and P. Loisel Evaluation of measurement strategies to increase the reliability of EMG indices to assess back muscle fatigue and recovery J. Electromyogr. Kinesiol. 12 2002 91 102
    • (2002) J. Electromyogr. Kinesiol. , vol.12 , pp. 91-102
    • Larevière, C.1    Arsenault, A.B.2    Gravel, D.3    Gagnon, D.4    Loisel, P.5
  • 23
    • 0031054583 scopus 로고    scopus 로고
    • Selective electromyography of dorsal neck muscles in humans
    • M.A. Mayoux-Benhamou, M. Revel, and C. Vallee Selective electromyography of dorsal neck muscles in humans Exp. Brain Res. 113 1997 353 360
    • (1997) Exp. Brain Res. , vol.113 , pp. 353-360
    • Mayoux-Benhamou, M.A.1    Revel, M.2    Vallee, C.3
  • 26
    • 0029881873 scopus 로고    scopus 로고
    • Reliability of electromyographic power spectral analysis of back muscle endurance in healthy subjects
    • J.K. Ng, and C.A. Richardson Reliability of electromyographic power spectral analysis of back muscle endurance in healthy subjects Arch. Phys. Med. Rehabil. 77 1996 259 264
    • (1996) Arch. Phys. Med. Rehabil. , vol.77 , pp. 259-264
    • Ng, J.K.1    Richardson, C.A.2
  • 28
    • 0032170777 scopus 로고    scopus 로고
    • Reliability of spectral EMG parameters of healthy back extensors during submaximum isometric fatiguing contractions and recovery
    • J.P. Peach, J. Gunning, and S.M. McGill Reliability of spectral EMG parameters of healthy back extensors during submaximum isometric fatiguing contractions and recovery J. Electromyogr. Kinesiol. 8 1998 403 410
    • (1998) J. Electromyogr. Kinesiol. , vol.8 , pp. 403-410
    • Peach, J.P.1    Gunning, J.2    McGill, S.M.3
  • 29
    • 0035234780 scopus 로고    scopus 로고
    • Intra- and inter-tester reliability and reference values for isometric neck strength
    • A. Peolsson, B. Oberg, and R. Hedlund Intra- and inter-tester reliability and reference values for isometric neck strength Physiother. Res. Int. 6 2001 15 26
    • (2001) Physiother. Res. Int. , vol.6 , pp. 15-26
    • Peolsson, A.1    Oberg, B.2    Hedlund, R.3
  • 30
    • 0021066150 scopus 로고
    • Neck muscle loading and fatigue: Systematic variation of headgear weight and center-of-gravity
    • C.A. Phillips, and J.S. Petrofsky Neck muscle loading and fatigue: systematic variation of headgear weight and center-of-gravity Aviat. Space Environ. Med. 54 1983 901 905
    • (1983) Aviat. Space Environ. Med. , vol.54 , pp. 901-905
    • Phillips, C.A.1    Petrofsky, J.S.2
  • 31
    • 0020521428 scopus 로고
    • Quantitative electromyography: Response of the neck muscles to conventional helmet loading
    • C.A. Phillips, and J.S. Petrofsky Quantitative electromyography: response of the neck muscles to conventional helmet loading Aviat. Space Environ. Med. 54 1983 452 457
    • (1983) Aviat. Space Environ. Med. , vol.54 , pp. 452-457
    • Phillips, C.A.1    Petrofsky, J.S.2
  • 32
    • 0022621123 scopus 로고
    • A computer model of neck muscle endurance and fatigue as a function of helmet loading
    • C.A. Phillips, and J.S. Petrofsky A computer model of neck muscle endurance and fatigue as a function of helmet loading Comput. Biol. Med. 16 1986 103 130
    • (1986) Comput. Biol. Med. , vol.16 , pp. 103-130
    • Phillips, C.A.1    Petrofsky, J.S.2
  • 34
    • 0034949861 scopus 로고    scopus 로고
    • Effects of resistance training in humans on neck muscle performance, and electromyogram power spectrum changes
    • P. Portero, A.X. Bigard, D. Gamet, J.R. Flageat, and C.Y. Guezennec Effects of resistance training in humans on neck muscle performance, and electromyogram power spectrum changes Eur. J. Appl. Physiol. 84 2001 540 546
    • (2001) Eur. J. Appl. Physiol. , vol.84 , pp. 540-546
    • Portero, P.1    Bigard, A.X.2    Gamet, D.3    Flageat, J.R.4    Guezennec, C.Y.5
  • 35
    • 0023721141 scopus 로고
    • On neck muscle activity and load reduction in sitting postures. An electromyographic and biomechanical study with applications in ergonomics and rehabilitation
    • K. Schüldt On neck muscle activity and load reduction in sitting postures. An electromyographic and biomechanical study with applications in ergonomics and rehabilitation Scand. J. Rehabil. Med. Suppl. 19 1988 1 49
    • (1988) Scand. J. Rehabil. Med. Suppl. , vol.19 , pp. 1-49
    • Schüldt, K.1
  • 36
    • 0023748508 scopus 로고
    • Activity levels during isometric test contractions of neck and shoulder muscles
    • K. Schüldt, and K. Harms-Ringdahl Activity levels during isometric test contractions of neck and shoulder muscles Scand. J. Rehabil. Med. 20 1988 117 127
    • (1988) Scand. J. Rehabil. Med. , vol.20 , pp. 117-127
    • Schüldt, K.1    Harms-Ringdahl, K.2
  • 39
    • 0038416060 scopus 로고    scopus 로고
    • Neck muscle activity in helicopter pilots: Effect of position and helmet-mounted equipment
    • M. Thuresson, B. Ang, J. Linder, and K. Harms-Ringdahl Neck muscle activity in helicopter pilots: effect of position and helmet-mounted equipment Aviat. Space Environ. Med. 74 2003 527 532
    • (2003) Aviat. Space Environ. Med. , vol.74 , pp. 527-532
    • Thuresson, M.1    Ang, B.2    Linder, J.3    Harms-Ringdahl, K.4
  • 40
    • 0029927571 scopus 로고    scopus 로고
    • Reproducibility of isometric trunk extension torque, trunk extensor endurance, and related electromyographic parameters in the context of their clinical applicability
    • J.H. van Dieën, and P. Heijblom Reproducibility of isometric trunk extension torque, trunk extensor endurance, and related electromyographic parameters in the context of their clinical applicability J. Orthop. Res. 14 1996 139 143
    • (1996) J. Orthop. Res. , vol.14 , pp. 139-143
    • Van Dieën, J.H.1    Heijblom, P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.