Volumn 20, Issue 2, 2005, Pages 244-249

Migration of cemented stem and restrictor after total hip arthroplasty: A radiostereometry study of 25 patients with Lubinus SP II stem

Author keywords

Anatomic stem; Bone cement interface; Radiostereometry; Subsidence; Total hip arthroplasty

Indexed keywords

BONE CEMENT;

EID: 14844314142     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arth.2004.09.039     Document Type: Article
Times cited : (15)

References (16)
  • 1
    • 0033755596 scopus 로고    scopus 로고
    • Are the findings in the Swedish National Total Hip Arthroplasty Register valid? a comparison between the Swedish National Total Hip Arthroplasty Register, the National Discharge Register, and the National Death Register
    • P. Soderman, H. Malchau, and P. Herberts Are the findings in the Swedish National Total Hip Arthroplasty Register valid? A comparison between the Swedish National Total Hip Arthroplasty Register, the National Discharge Register, and the National Death Register J. Arthroplasty 15 2000 884
    • (2000) J. Arthroplasty , vol.15 , pp. 884
    • Soderman, P.1    Malchau, H.2    Herberts, P.3
  • 2
    • 0032945290 scopus 로고    scopus 로고
    • Cement migration after THR. A comparison of Charnley Elite and Exeter femoral stems using RSA
    • J. Alfaro-Adrian, H.S. Gill, and D.W. Murray Cement migration after THR. A comparison of Charnley Elite and Exeter femoral stems using RSA J. Bone Joint Surg. Br. 81 1999 130
    • (1999) J. Bone Joint Surg. Br. , vol.81 , pp. 130
    • Alfaro-Adrian, J.1    Gill, H.S.2    Murray, D.W.3
  • 3
    • 0028282143 scopus 로고
    • Early migration and late aseptic failure of proximal femoral prostheses
    • M.A.R. Freeman, and P. Plante-Bordeneuve Early migration and late aseptic failure of proximal femoral prostheses J. Bone Joint Surg. Br. 76 1994 432
    • (1994) J. Bone Joint Surg. Br. , vol.76 , pp. 432
    • Freeman, M.A.R.1    Plante-Bordeneuve, P.2
  • 4
    • 0018266086 scopus 로고
    • Stereo-radiologische localisationdiagnostik von schalen und totalendoprothesen des huftgelenkes
    • K.J. Probst, A. Herp, and W. Leidel Stereo-radiologische localisationdiagnostik von schalen und totalendoprothesen des huftgelenkes Arch. Orthop. Trauma Surg. 92 1978 75
    • (1978) Arch. Orthop. Trauma Surg. , vol.92 , pp. 75
    • Probst, K.J.1    Herp, A.2    Leidel, W.3
  • 5
    • 0020453160 scopus 로고
    • A comparison of convergent and bi-plane x-ray photogrammetry systems used to detect total joint loosening
    • F.G. Lippert III, R.M. Harrington, and S.A. Veress A comparison of convergent and bi-plane x-ray photogrammetry systems used to detect total joint loosening J. Biomech. 15 1982 677
    • (1982) J. Biomech. , vol.15 , pp. 677
    • Lippert III, F.G.1    Harrington, R.M.2    Veress, S.A.3
  • 6
    • 0020578271 scopus 로고
    • Biplane radiographic measurements of reversible displacement (including clinical loosening) and migration of total joint replacements
    • D.L. Green, E. Bahniuk, and R.A. Liebelt Biplane radiographic measurements of reversible displacement (including clinical loosening) and migration of total joint replacements J. Bone Joint Surg. Am. 65 1983 1134
    • (1983) J. Bone Joint Surg. Am. , vol.65 , pp. 1134
    • Green, D.L.1    Bahniuk, E.2    Liebelt, R.A.3
  • 8
    • 0343118727 scopus 로고    scopus 로고
    • Radiostereometry of hip prostheses. Review of methodology and clinical results
    • J. Karrholm, P. Herberts, and P. Hultmark Radiostereometry of hip prostheses. Review of methodology and clinical results Clin. Orthop. 344 1997 94
    • (1997) Clin. Orthop. , vol.344 , pp. 94
    • Karrholm, J.1    Herberts, P.2    Hultmark, P.3
  • 9
    • 0024388994 scopus 로고
    • Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system
    • G. Selvik Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system Acta Orthop. Scand. 232 Suppl. 1989 1
    • (1989) Acta Orthop. Scand. , vol.232 , Issue.SUPPL. , pp. 1
    • Selvik, G.1
  • 10
    • 0028034860 scopus 로고
    • Does early micromotion of femoral stem prostheses matter? 4-7-Year stereoradiographic follow-up of 84 cemented prostheses
    • J. Karrholm, B. Borssen, and G. Lowenhielm Does early micromotion of femoral stem prostheses matter? 4-7-Year stereoradiographic follow-up of 84 cemented prostheses J. Bone Joint Surg. Br. 76 1994 912
    • (1994) J. Bone Joint Surg. Br. , vol.76 , pp. 912
    • Karrholm, J.1    Borssen, B.2    Lowenhielm, G.3
  • 11
    • 0032863856 scopus 로고    scopus 로고
    • Mid-term migration of a cemented total hip replacement assessed by radiostereometric analysis
    • J. Alfaro-Adrian, H.S. Gill, and B.E. Marks Mid-term migration of a cemented total hip replacement assessed by radiostereometric analysis Int. Orthop. 23 1999 140
    • (1999) Int. Orthop. , vol.23 , pp. 140
    • Alfaro-Adrian, J.1    Gill, H.S.2    Marks, B.E.3
  • 12
    • 0034886433 scopus 로고    scopus 로고
    • Should total hip arthroplasty femoral components be designed to subside? a radiostereometric analysis study of the Charnley Elite and Exeter stems
    • J. Alfaro-Adrian, H.S. Gill, and D.W. Murray Should total hip arthroplasty femoral components be designed to subside? A radiostereometric analysis study of the Charnley Elite and Exeter stems J. Arthroplasty 16 2001 598
    • (2001) J. Arthroplasty , vol.16 , pp. 598
    • Alfaro-Adrian, J.1    Gill, H.S.2    Murray, D.W.3
  • 15
    • 0030482427 scopus 로고    scopus 로고
    • Hybrid total hip replacement: Rationale and intermediate clinical results
    • W.H. Harris Hybrid total hip replacement: rationale and intermediate clinical results Clin. Orthop. 333 1996 155
    • (1996) Clin. Orthop. , vol.333 , pp. 155
    • Harris, W.H.1
  • 16
    • 0033372584 scopus 로고    scopus 로고
    • Increased migration of the SHP prosthesis: Radiostereometric comparison with the Lubinus SP2 design in 40 cases
    • B. Nivbrant, J. Karrholm, and P. Soderlund Increased migration of the SHP prosthesis: radiostereometric comparison with the Lubinus SP2 design in 40 cases Acta Orthop. Scand. 70 1999 569
    • (1999) Acta Orthop. Scand. , vol.70 , pp. 569
    • Nivbrant, B.1    Karrholm, J.2    Soderlund, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.