메뉴 건너뛰기




Volumn 59, Issue 4, 2005, Pages 361-364

Residual formaldehyde on plastic materials and medical equipment following low-temperature steam and formaldehyde sterilization

Author keywords

European Standard EN14180; Low temperature steam and formaldehyde sterilization; Medical materials; Residual formaldehyde

Indexed keywords

FORMALDEHYDE; PLASTIC; POLYAMIDE; POLYURETHAN; RUBBER;

EID: 14744305126     PISSN: 01956701     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jhin.2004.09.039     Document Type: Article
Times cited : (7)

References (9)
  • 1
    • 14744298987 scopus 로고    scopus 로고
    • Sterilizers for medical purposes-low temperature steam and formaldehyde sterilizers-requirements and testing
    • Technical Committee CEN/TC 102. London, UK. EN 14180 British Standard Institution
    • Technical Committee CEN/TC 102. Sterilizers for medical purposes-low temperature steam and formaldehyde sterilizers-requirements and testing. British Standard Institution, London, UK. EN 14180 2001.
    • (2001)
  • 2
    • 14744289116 scopus 로고    scopus 로고
    • Guidelines for basic biological tests of medical materials and devices
    • Ministry of Health, Labour and Welfare of Japan. Pharmaceutical and Food Safety Bureau Tokyo, Japan: Ministry of Health, Labour and Welfare of Japan
    • Ministry of Health, Labour and Welfare of Japan. Pharmaceutical and Food Safety Bureau p. 187 Guidelines for basic biological tests of medical materials and devices 1996 Ministry of Health, Labour and Welfare of Japan Tokyo, Japan
    • (1996) , pp. 187
  • 3
    • 0004310686 scopus 로고    scopus 로고
    • Biological evaluation of medical device - Part 12: Sample preparation and reference materials
    • International Organization for Standardization. ISO 10993-12
    • International Organization for Standardization. Biological evaluation of medical device - Part 12: Sample preparation and reference materials. ISO 10993-12. 2002.
    • (2002)
  • 4
    • 0033845248 scopus 로고    scopus 로고
    • Decontamination of minimally invasive surgical endoscopes and accessories
    • J. Babb G. Ayliffe C. Bradley Decontamination of minimally invasive surgical endoscopes and accessories J Hosp Infect 45 2000 263-277
    • (2000) J. Hosp. Infect. , vol.45 , pp. 263-277
    • Babb, J.1    Ayliffe, G.2    Bradley, C.3
  • 5
    • 0035032162 scopus 로고    scopus 로고
    • New disinfection and sterilization methods
    • W.A. Rutala D.J. Weber New disinfection and sterilization methods Emerg Infect Dis 7 2001 348-353
    • (2001) Emerg. Infect. Dis. , vol.7 , pp. 348-353
    • Rutala, W.A.1    Weber, D.J.2
  • 6
    • 0348240498 scopus 로고
    • Formaldehyde sterilization-1. Determination of formaldehyde residuals in autoclave sterilized materials
    • V. Handlos Formaldehyde sterilization-1. Determination of formaldehyde residuals in autoclave sterilized materials Arch Pharm Chem 5 1977 163-169
    • (1977) Arch. Pharm. Chem. , vol.5 , pp. 163-169
    • Handlos, V.1
  • 7
    • 0007180961 scopus 로고
    • Formaldehyde sterilization-2. Formaldehyde-steam sterilization, the process and its influence on the formaldehyde residuals
    • V. Handlos Formaldehyde sterilization-2. Formaldehyde-steam sterilization, the process and its influence on the formaldehyde residuals Arch Pharm Chem 7 1979 1-2
    • (1979) Arch. Pharm. Chem. , vol.7 , pp. 1-2
    • Handlos, V.1
  • 8
    • 14744289469 scopus 로고
    • Formaldehyde sterilization-3. The behaviour of the loaded autoclave and the permeability of plastic materials to formaldehyde
    • V. Handlos Formaldehyde sterilization-3. The behaviour of the loaded autoclave and the permeability of plastic materials to formaldehyde Arch Pharm Chem 7 1979 12-18
    • (1979) Arch. Pharm. Chem. , vol.7 , pp. 12-18
    • Handlos, V.1
  • 9
    • 0142087673 scopus 로고    scopus 로고
    • Evaluation of low temperature steam and formaldehyde sterilizer
    • K. Kanemitsu H. Kunishima M. Kaky et al. Evaluation of low temperature steam and formaldehyde sterilizer J Hosp Infect 55 2003 47-52
    • (2003) J. Hosp. Infect. , vol.55 , pp. 47-52
    • Kanemitsu, K.1    Kunishima, H.2    Kaky, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.