메뉴 건너뛰기




Volumn 105, Issue 2, 2005, Pages 464-472

Determination of metastable zone width in cooling crystallization with a quartz crystal sensor

Author keywords

Crystallization; Quartz crystal sensor; Resonant frequency; Supersaturation

Indexed keywords

ACOUSTIC SURFACE WAVE DEVICES; CONTAMINATION; COOLING; CRYSTALLIZATION; CRYSTALS; IMPURITIES; NATURAL FREQUENCIES; PHOTOGRAPHY; POTASSIUM COMPOUNDS; QUARTZ; SALTS; SOLUTIONS; SUPERSATURATION; TRANSDUCERS;

EID: 14744300422     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2004.07.004     Document Type: Article
Times cited : (22)

References (6)
  • 1
    • 0040837528 scopus 로고    scopus 로고
    • The SeedMaster device-for on-line supersaturation measurement and automatic crystalliser seeding
    • L. Rozsa The SeedMaster device-for on-line supersaturation measurement and automatic crystalliser seeding Int. Sugar J. 100 1998 601 607
    • (1998) Int. Sugar J. , vol.100 , pp. 601-607
    • Rozsa, L.1
  • 2
    • 0037138069 scopus 로고    scopus 로고
    • A new method for supersaturation measurement: Idea, implementation and results
    • M. Löffelmann, and A. Mersmann A new method for supersaturation measurement: idea, implementation and results Int. J. Mod. Phys. B 16 2002 391 398
    • (2002) Int. J. Mod. Phys. B , vol.16 , pp. 391-398
    • Löffelmann, M.1    Mersmann, A.2
  • 3
    • 0036868654 scopus 로고    scopus 로고
    • How to measure supersaturation?
    • M. Löffelmann, and A. Mersmann How to measure supersaturation? Chem. Eng. Sci. 57 2002 4301 4310
    • (2002) Chem. Eng. Sci. , vol.57 , pp. 4301-4310
    • Löffelmann, M.1    Mersmann, A.2
  • 4
    • 0142075290 scopus 로고    scopus 로고
    • Crystallization monitoring in supersaturated solution with a quartz crystal sensor
    • B.C. Kim, Y.H. Kim, and K. Fukui Crystallization monitoring in supersaturated solution with a quartz crystal sensor Anal. Chim. Acta 491 2003 71 80
    • (2003) Anal. Chim. Acta , vol.491 , pp. 71-80
    • Kim, B.C.1    Kim, Y.H.2    Fukui, K.3
  • 5
    • 0037111502 scopus 로고    scopus 로고
    • Fabrication and application of an activated carbon-coated quartz crystal sensor
    • Y.H. Kim, and K.J. Choi Fabrication and application of an activated carbon-coated quartz crystal sensor Sen. Actuators B 87 2002 196 200
    • (2002) Sen. Actuators B , vol.87 , pp. 196-200
    • Kim, Y.H.1    Choi, K.J.2
  • 6
    • 0032998073 scopus 로고    scopus 로고
    • Characterization of aluminum corrosion with a quartz crystal analyzer
    • K.J. Choi, Y.H. Kim, S.M. Chang, A. Egawa, and H. Muramatsu Characterization of aluminum corrosion with a quartz crystal analyzer Anal. Chim. Acta 386 1999 229 236
    • (1999) Anal. Chim. Acta , vol.386 , pp. 229-236
    • Choi, K.J.1    Kim, Y.H.2    Chang, S.M.3    Egawa, A.4    Muramatsu, H.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.