1
-
-
0141638819
-
Washer-disinfectors-Part 1. General requirements, definitions and tests
-
prEN ISO 15883-1. Beuth Verlag; Deutsches Institut Für Normung
-
prEN ISO 15883-1. Washer-disinfectors-Part 1. General requirements, definitions and tests. Deutsches Institut Für Normung: Beuth Verlag; 2002.
-
(2002)
-
-
-
2
-
-
0141527683
-
Washer-disinfectors-Part 4. Requirements and tests for washer-disinfectors employing chemical disinfection for thermo-labile endoscopes
-
prEN ISO 15883-4. Beuth Verlag; Deutsches Institut Für Normung
-
prEN ISO 15883-4. Washer-disinfectors-Part 4. Requirements and tests for washer-disinfectors employing chemical disinfection for thermo-labile endoscopes. Deutsches Institut Für Normung: Beuth Verlag; 2002.
-
(2002)
-
-
-
3
-
-
14744294503
-
Washer-disinfectors-Part 2. Requirements and tests for washer-disinfectors employing thermal disinfection for surgical instruments, anaesthetic equipment, hollowware, utensils, glassware, etc
-
prEN ISO 15883-2. Beuth Verlag; Deutsches Institut Für Normung
-
prEN ISO 15883-2. Washer-disinfectors-Part 2. Requirements and tests for washer-disinfectors employing thermal disinfection for surgical instruments, anaesthetic equipment, hollowware, utensils, glassware, etc. Deutsches Institut Für Normung: Beuth Verlag; 2002.
-
(2002)
-
-
-
4
-
-
14744305183
-
Washer-disinfectors-Part 3. Requirements and tests for washer-disinfectors employing thermal disinfection for human waste containers
-
prEN ISO 15883-3. Beuth Verlag; Deutsches Institut Für Normung
-
prEN ISO 15883-3. Washer-disinfectors-Part 3. Requirements and tests for washer-disinfectors employing thermal disinfection for human waste containers. Deutsches Institut Für Normung: Beuth Verlag; 2002.
-
(2002)
-
-
-
5
-
-
0003187870
-
Prüfung und Bewertung der Reinigungs- und Desinfektionswirkung von Endoskop-Dekontaminationsautomaten sowie-Desinfektionsautomaten
-
Arbeitskreis Endoskopie der DGKH
-
Arbeitskreis Endoskopie der DGKH Prüfung und Bewertung der Reinigungs- und Desinfektionswirkung von Endoskop-Dekontaminationsautomaten sowie-Desinfektionsautomaten Hyg Med 20 1995 40-47
-
(1995)
Hyg. Med.
, vol.20
, pp. 40-47
-
-
-
6
-
-
0032862918
-
Worst-case soiling levels for patient-used flexible endoscopes before and after cleaning
-
M.J. Alfa P. Degagne N. Olson Worst-case soiling levels for patient-used flexible endoscopes before and after cleaning Am J Infect Control 27 1999 392-401
-
(1999)
Am. J. Infect. Control
, vol.27
, pp. 392-401
-
-
Alfa, M.J.1
Degagne, P.2
Olson, N.3
-
7
-
-
0031841571
-
Natural bioburden levels detected on flexible gastrointestinal endoscopes after clinical use and manual cleaning
-
N. Chu D. McAlister P.A. Antonoplos Natural bioburden levels detected on flexible gastrointestinal endoscopes after clinical use and manual cleaning Gastrointest Endosc 48 1998 137-142
-
(1998)
Gastrointest. Endosc.
, vol.48
, pp. 137-142
-
-
Chu, N.1
McAlister, D.2
Antonoplos, P.A.3
-
8
-
-
0033085123
-
Microbial bioburden in endoscope reprocessing and an in-use evaluation of the high-level disinfection capabilities of Cidex PA
-
D. Vesley J. Melson P. Stanley Microbial bioburden in endoscope reprocessing and an in-use evaluation of the high-level disinfection capabilities of Cidex PA Gastroenterol Nurse 22 1999 63-68
-
(1999)
Gastroenterol. Nurse
, vol.22
, pp. 63-68
-
-
Vesley, D.1
Melson, J.2
Stanley, P.3
-
9
-
-
0003187870
-
Prüfung und Bewertung der Reinigungs- und Desinfektionswirkung von Endoskop-Dekontaminationsautomaten sowie-Desinfektionsautomaten
-
Anonymous [Hyg Med 2001;26:524]
-
Anonymous Prüfung und Bewertung der Reinigungs- und Desinfektionswirkung von Endoskop-Dekontaminationsautomaten sowie-Desinfektionsautomaten Hyg Med 20 1995 40-47 [Hyg Med 2001;26:524]
-
(1995)
Hyg. Med.
, vol.20
, pp. 40-47
-
-
-
10
-
-
0029283682
-
FDA labeling requirements for disinfection of endoscopes: A counterpoint
-
W.A. Rutala D.J. Weber FDA labeling requirements for disinfection of endoscopes: A counterpoint Infect Control Hosp Epidemiol 16 1995 231-235
-
(1995)
Infect. Control Hosp. Epidemiol.
, vol.16
, pp. 231-235
-
-
Rutala, W.A.1
Weber, D.J.2
-
11
-
-
0024339809
-
Contamination of endoscopes used in AIDS patients
-
P.J.V. Hanson D. Gor J.R. Clarke et al. Contamination of endoscopes used in AIDS patients Lancet 334 1989 86-88
-
(1989)
Lancet
, vol.334
, pp. 86-88
-
-
Hanson, P.J.V.1
Gor, D.2
Clarke, J.R.3
-
13
-
-
0036835205
-
Cleaning efficacy of nine different cleaners in a washer-disinfector designed for flexible endoscopes
-
B. Zühlsdorf M. Emmrich H. Floss H. Martiny Cleaning efficacy of nine different cleaners in a washer-disinfector designed for flexible endoscopes J Hosp Infect 52 2002 206-211
-
(2002)
J. Hosp. Infect.
, vol.52
, pp. 206-211
-
-
Zühlsdorf, B.1
Emmrich, M.2
Floss, H.3
Martiny, H.4
-
14
-
-
1842557973
-
Efficacy of ten different cleaners in a washer-disinfector for flexible endoscopes
-
B. Zühlsdorf H. Floss H. Martiny Efficacy of ten different cleaners in a washer-disinfector for flexible endoscopes J Hosp Infect 56 2004 305-311
-
(2004)
J. Hosp. Infect.
, vol.56
, pp. 305-311
-
-
Zühlsdorf, B.1
Floss, H.2
Martiny, H.3
-
15
-
-
0022369269
-
Eine Methode zur Kontamination von Testobjekten mit gerinnendem Blut
-
G. Spicher J Peters Eine Methode zur Kontamination von Testobjekten mit gerinnendem Blut. (A method of contaminating test objects with coagulating blood) Zbl Bakt Hyg B 182 1985 89-94
-
(1985)
Zbl Bakt Hyg. B
, vol.182
, pp. 89-94
-
-
Spicher, G.1
Peters, J.2
-
16
-
-
0005504340
-
Hepatitis C
-
W.B. Haubrich J.E. Schaffner FBerk (Eds.) 5th edn WB Saunders Philadelphia
-
G.L. Davies J.Y.N. Lau Hepatitis C In: W.B. Haubrich J.E. Schaffner FBerk (Eds.) Gastroenterology 5th edn 1995 WB Saunders Philadelphia 2082-2114
-
(1995)
Gastroenterology
, pp. 2082-2114
-
-
Davies, G.L.1
Lau, J.Y.N.2
-
18
-
-
1942417548
-
Surface fixation of dried blood by glutaraldehyde and peracetic acid
-
G. Kampf R. Bloß H. Martiny Surface fixation of dried blood by glutaraldehyde and peracetic acid J Hosp Infect 57 2004 139-143
-
(2004)
J. Hosp. Infect.
, vol.57
, pp. 139-143
-
-
Kampf, G.1
Bloß, R.2
Martiny, H.3
-
20
-
-
0030764517
-
Patient-to-patient transmission of hepatitis C virus during colonoscopy
-
J.P. Bronowicki V. Vernard C. Botte et al. Patient-to-patient transmission of hepatitis C virus during colonoscopy N Engl J Med 337 1997 237-240
-
(1997)
N. Engl. J. Med.
, vol.337
, pp. 237-240
-
-
Bronowicki, J.P.1
Vernard, V.2
Botte, C.3
-
21
-
-
0242652448
-
Efficiency of enzymatic and conventional detergent cleaners for removing organic material from instruments prior to reprocessing
-
[Poster 12 (abstract)]
-
H.B. Chan-Myers S. Chu Efficiency of enzymatic and conventional detergent cleaners for removing organic material from instruments prior to reprocessing Am J Infect Control 29 2001 [Poster 12 (abstract)]
-
(2001)
Am. J. Infect. Control
, vol.29
-
-
Chan-Myers, H.B.1
Chu, S.2
-
22
-
-
0021766257
-
Bacterial adherence to plastics: A role in endoscope-transmitted infections
-
G.A. Botta A.G.M.A. Costa V. Pugliese Bacterial adherence to plastics: A role in endoscope-transmitted infections Lancet 323 1984 398-399
-
(1984)
Lancet
, vol.323
, pp. 398-399
-
-
Botta, G.A.1
Costa, A.G.M.A.2
Pugliese, V.3
-
23
-
-
0021756818
-
Adherence of bacteria associated with active chronic gastritis to plastics used in the manufacture of fibreoptic endoscopes
-
C.R. Fricker Adherence of bacteria associated with active chronic gastritis to plastics used in the manufacture of fibreoptic endoscopes Lancet 323 1984 800
-
(1984)
Lancet
, vol.323
, pp. 800
-
-
Fricker, C.R.1
|