Volumn 71, Issue 5, 2005, Pages 851-852

Blood pressure measurement in public places

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; BLOOD PRESSURE MEASUREMENT; BLOOD PRESSURE MONITORING; DIAGNOSTIC ERROR; DIASTOLIC BLOOD PRESSURE; EDITORIAL; GENERAL PRACTITIONER; HUMAN; HYPERTENSION; LOWEST INCOME GROUP; SELF EXAMINATION; SYSTOLIC BLOOD PRESSURE;

EID: 14644440544     PISSN: 0002838X     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Editorial
Times cited : (12)

References (13)
  • 1
    • 0038460302 scopus 로고    scopus 로고
    • The seventh report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure: The JNC 7 report
    • published correction appears in JAMA 2003;290:197
    • Chobanian AV, Bakris GL, Black HR, Cushman WC, Green LA, Izzo JL Jr, et al. The seventh report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure: the JNC 7 report [published correction appears in JAMA 2003;290:197]. JAMA 2003;289:2560-72.
    • (2003) JAMA , vol.289 , pp. 2560-2572
    • Chobanian, A.V.1    Bakris, G.L.2    Black, H.R.3    Cushman, W.C.4    Green, L.A.5    Izzo Jr., J.L.6
  • 2
    • 0035984999 scopus 로고    scopus 로고
    • The role of home blood pressure measurement in managing hypertension: An evidence-based review
    • Rickerby J. The role of home blood pressure measurement in managing hypertension: an evidence-based review. J Hum Hypertens 2002;16:469-72.
    • (2002) J Hum Hypertens , vol.16 , pp. 469-472
    • Rickerby, J.1
  • 3
    • 0037665053 scopus 로고    scopus 로고
    • Do community based self-reading sphygmomanometers improve detection of hypertension? A feasibility study
    • Hamilton W, Round A, Goodchild R, Baker C. Do community based self-reading sphygmomanometers improve detection of hypertension? A feasibility study. J Public Health Med 2003;25:125-30.
    • (2003) J Public Health Med , vol.25 , pp. 125-130
    • Hamilton, W.1    Round, A.2    Goodchild, R.3    Baker, C.4
  • 4
    • 0036264213 scopus 로고    scopus 로고
    • Evaluation of a community-based automated blood pressure measuring device
    • published correction appears in CMAJ 2002;166:1512
    • Lewis JE, Boyle E, Magharious L, Myers MG. Evaluation of a community-based automated blood pressure measuring device [published correction appears in CMAJ 2002;166:1512]. CMAJ 2002;166:1145-8.
    • (2002) CMAJ , vol.166 , pp. 1145-1148
    • Lewis, J.E.1    Boyle, E.2    Magharious, L.3    Myers, M.G.4
  • 5
    • 0029299374 scopus 로고
    • Failure of the community-based Vita-Stat automated blood pressure device to accurately measure blood pressure
    • Whitcomb BL, Prochazka A, LoVerde M, Byyny RL. Failure of the community-based Vita-Stat automated blood pressure device to accurately measure blood pressure. Arch Fam Med 1995;4:419-24.
    • (1995) Arch Fam Med , vol.4 , pp. 419-424
    • Whitcomb, B.L.1    Prochazka, A.2    LoVerde, M.3    Byyny, R.L.4
  • 6
    • 0036550087 scopus 로고    scopus 로고
    • Patient use of automatic blood pressure measures in retail stores: Implications for diagnosis and treatment of hypertension
    • Thiedke CC, Laird S, Detar DT, Mainous AG 3d, Jenkins K, Ye X. Patient use of automatic blood pressure measures in retail stores: implications for diagnosis and treatment of hypertension. J S C Med Assoc 2002;98:67-71.
    • (2002) J S C Med Assoc , vol.98 , pp. 67-71
    • Thiedke, C.C.1    Laird, S.2    Detar, D.T.3    Mainous III, A.G.4    Jenkins, K.5    Ye, X.6
  • 8
    • 0025313326 scopus 로고
    • A community-based evaluation of the Vita-Stat automatic blood pressure recorder
    • Salaita K, Whelton PK, Seidler AJ. A community-based evaluation of the Vita-Stat automatic blood pressure recorder. Am J Hypertens 1990;3(5 pt 1):366-72.
    • (1990) Am J Hypertens , vol.3 , Issue.5 PART 1 , pp. 366-372
    • Salaita, K.1    Whelton, P.K.2    Seidler, A.J.3
  • 9
    • 0020678374 scopus 로고
    • Evaluation of the Vita-Stat automatic blood pressure recorder. A comparison with the Random-Zero sphygmomanometer
    • Whelton PK, Thompson SG, Barnes GR, Miall WE. Evaluation of the Vita-Stat automatic blood pressure recorder. A comparison with the Random-Zero sphygmomanometer. Am J Epidemiol 1983;117:46-54.
    • (1983) Am J Epidemiol , vol.117 , pp. 46-54
    • Whelton, P.K.1    Thompson, S.G.2    Barnes, G.R.3    Miall, W.E.4
  • 10
    • 0019307142 scopus 로고
    • An evaluation of the Vita-Stat automatic blood pressure measuring device
    • Polk BF, Rosner B, Feudo R, Vandenburgh M. An evaluation of the Vita-Stat automatic blood pressure measuring device. Hypertension 1980;2:221-7.
    • (1980) Hypertension , vol.2 , pp. 221-227
    • Polk, B.F.1    Rosner, B.2    Feudo, R.3    Vandenburgh, M.4
  • 11
    • 0001872430 scopus 로고    scopus 로고
    • Performance review of a noninvasive blood pressure monitor
    • Nara AR. Performance review of a noninvasive blood pressure monitor. Med Electron 1996;27:63-7.
    • (1996) Med Electron , vol.27 , pp. 63-67
    • Nara, A.R.1
  • 12
    • 3042735707 scopus 로고    scopus 로고
    • The changing distribution of arm circumferences in NHANES III and NHANES 2000 and its impact on the utility of the 'standard adult' blood pressure cuff
    • Graves JW, Bailey KR, Sheps SG. The changing distribution of arm circumferences in NHANES III and NHANES 2000 and its impact on the utility of the 'standard adult' blood pressure cuff. Blood Press Monit 2003;8:223-7.
    • (2003) Blood Press Monit , vol.8 , pp. 223-227
    • Graves, J.W.1    Bailey, K.R.2    Sheps, S.G.3
  • 13
    • 0020085568 scopus 로고
    • Error in blood-pressure measurement due to incorrect cuff size in obese patients
    • Maxwell MH, Waks AU, Schroth PC, Karam M, Dornfeld LP. Error in blood-pressure measurement due to incorrect cuff size in obese patients. Lancet 1982;2:33-6.
    • (1982) Lancet , vol.2 , pp. 33-6
    • Maxwell, M.H.1    Waks, A.U.2    Schroth, P.C.3    Karam, M.4    Dornfeld, L.P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.