메뉴 건너뛰기




Volumn 16, Issue 2, 2005, Pages 201-204

Effects of temporal application parameters on lesion dimensions during transvenous catheter cryoablation

Author keywords

Ablation; Cryoablation; Lesion dimension

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ANIMAL TISSUE; ARTICLE; CATHETER ABLATION; CONTROLLED STUDY; ELECTRODE; FEMALE; FREEZE THAWING; HEART INJURY; INTRAVENOUS CATHETER; MULTIVARIATE ANALYSIS; NONHUMAN; PRIORITY JOURNAL; SWINE; THIGH; VEIN CATHETERIZATION;

EID: 14644438524     PISSN: 10453873     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1540-8167.2005.40559.x     Document Type: Article
Times cited : (43)

References (13)
  • 1
    • 0032856674 scopus 로고    scopus 로고
    • Cryothermal ablation: Mechanism of tissue injury and current experience in the treatment of tachyarrhythmias
    • Lustgarten DL, Keane D, Ruskin J: Cryothermal ablation: Mechanism of tissue injury and current experience in the treatment of tachyarrhythmias. Prog Cardiovasc Dis 1999;41:481-598.
    • (1999) Prog Cardiovasc Dis , vol.41 , pp. 481-598
    • Lustgarten, D.L.1    Keane, D.2    Ruskin, J.3
  • 4
    • 0033055475 scopus 로고    scopus 로고
    • Blood damage, platelet and clotting activation during application of radiofrequency or cryoablation catheters: A comparative in vitro study
    • Van Oeveren W, Crijns HJ, Korteling BJ, Wegereef EW, Haan J, Tigchelaar I, Hoekstra A: Blood damage, platelet and clotting activation during application of radiofrequency or cryoablation catheters: A comparative in vitro study. J Med Eng Technol 1999;23:20-25.
    • (1999) J Med Eng Technol , vol.23 , pp. 20-25
    • Van Oeveren, W.1    Crijns, H.J.2    Korteling, B.J.3    Wegereef, E.W.4    Haan, J.5    Tigchelaar, I.6    Hoekstra, A.7
  • 10
    • 0023775991 scopus 로고
    • Cardiac cryolesions: Factors affecting their size and a means of monitoring their formation
    • Markovitz LJ, Frame LH, Josephson ME, Hargrove WC 3rd: Cardiac cryolesions: Factors affecting their size and a means of monitoring their formation. Ann Thorac Surg 1988;46:531-535.
    • (1988) Ann Thorac Surg , vol.46 , pp. 531-535
    • Markovitz, L.J.1    Frame, L.H.2    Josephson, M.E.3    Hargrove III, W.C.4
  • 11
    • 0028942447 scopus 로고
    • Comparison of in vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature control in a canine thigh muscle preparation
    • Nakagawa H, Yamanashi WS, Pitha JV, Arruda M, Wang X, Ohtomo K, Beckman KJ, McClelland JH, Lazzara R, Jackman WM: Comparison of in vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature control in a canine thigh muscle preparation. Circulation 1995;91:2264-2273.
    • (1995) Circulation , vol.91 , pp. 2264-2273
    • Nakagawa, H.1    Yamanashi, W.S.2    Pitha, J.V.3    Arruda, M.4    Wang, X.5    Ohtomo, K.6    Beckman, K.J.7    McClelland, J.H.8    Lazzara, R.9    Jackman, W.M.10


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.