Volumn 32, Issue 1, 2005, Pages 99-101

Thirty-seven-year durability of a Starr-Edwards aortic prosthesis: Case report and brief review of the literature

Author keywords

Aortic valve prosthesis; Durable medical equipment; Endocarditis, bacterial; Heart valve prosthesis; Human; Male; Postoperative complications; Reoperation; Time factors

Indexed keywords

CEFAZOLIN; GENTAMICIN; RIFAMPICIN; VANCOMYCIN;

EID: 14644413485     PISSN: 07302347     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (7)

References (12)
  • 2
    • 0027352202 scopus 로고
    • Twenty-four years' implant duration of the aortic Starr-Edwards Silastic ball prosthesis: A valve of the past?
    • Machler HE, Schmidt CH, Neuner P, Iberer F, Anelli-Monti M, Dacar D, et al. Twenty-four years' implant duration of the aortic Starr-Edwards Silastic ball prosthesis: a valve of the past? Eur J Cardiothorac Surg 1993;7:114-6.
    • (1993) Eur J Cardiothorac Surg , vol.7 , pp. 114-116
    • Machler, H.E.1    Schmidt, C.H.2    Neuner, P.3    Iberer, F.4    Anelli-Monti, M.5    Dacar, D.6
  • 3
    • 0342963080 scopus 로고
    • Starr-Edwards silastic ball prosthesis: State of the art 25 years later
    • Cobanoglu A, Starr A. Starr-Edwards silastic ball prosthesis: state of the art 25 years later. Cardiac Surg State Art Rev 1987;1:171-81.
    • (1987) Cardiac Surg State Art Rev , vol.1 , pp. 171-181
    • Cobanoglu, A.1    Starr, A.2
  • 5
    • 0343488401 scopus 로고    scopus 로고
    • Thirty years survival after double valve replacement with Starr-Edwards prostheses in aortic and mitral position
    • Godje O, Brenner P, Fischlein T, Reichart B. Thirty years survival after double valve replacement with Starr-Edwards prostheses in aortic and mitral position. Eur J Cardiothorac Surg 1997;11:391-3.
    • (1997) Eur J Cardiothorac Surg , vol.11 , pp. 391-393
    • Godje, O.1    Brenner, P.2    Fischlein, T.3    Reichart, B.4
  • 7
    • 0022576922 scopus 로고
    • Late ball variance with the Model 1000 Starr-Edwards aortic valve prosthesis. Risk analysis and strategy of operative management
    • Grunkemeier GL, Starr A. Late ball variance with the Model 1000 Starr-Edwards aortic valve prosthesis. Risk analysis and strategy of operative management. J Thorac Cardiovasc Surg 1986;91:918-23.
    • (1986) J Thorac Cardiovasc Surg , vol.91 , pp. 918-923
    • Grunkemeier, G.L.1    Starr, A.2
  • 8
    • 0028801291 scopus 로고
    • Guidelines for prevention of thromboembolic events in valvular heart disease
    • Study Group of the Working Group on Valvular Heart Disease of the European Society of Cardiology
    • Gohlke-Barwolf C, Acar J, Oakley C, Butchart E, Burckhart D, Bodnar E, et al. Guidelines for prevention of thromboembolic events in valvular heart disease. Study Group of the Working Group on Valvular Heart Disease of the European Society of Cardiology. Eur Heart J 1995;16:1320-30.
    • (1995) Eur Heart J , vol.16 , pp. 1320-1330
    • Gohlke-Barwolf, C.1    Acar, J.2    Oakley, C.3    Butchart, E.4    Burckhart, D.5    Bodnar, E.6
  • 9
    • 0026315348 scopus 로고
    • Value of transesophageal echocardiography as an adjunct to transthoracic echocardiography in evaluation of native and prosthetic valve endocarditis
    • Pedersen WR, Walker M, Olson JD, Gobel F, Lange HW, Daniel JA, et al. Value of transesophageal echocardiography as an adjunct to transthoracic echocardiography in evaluation of native and prosthetic valve endocarditis. Chest 1991; 100:351-6.
    • (1991) Chest , vol.100 , pp. 351-356
    • Pedersen, W.R.1    Walker, M.2    Olson, J.D.3    Gobel, F.4    Lange, H.W.5    Daniel, J.A.6
  • 10
    • 0038488380 scopus 로고    scopus 로고
    • Reoperation for a Starr-Edwards ball valve prosthesis implanted in mitral position 31 position years ago
    • Goshima M, Shiono M, Yamamoto T, Inoue T, Hata M, Sezai A, et al. Reoperation for a Starr-Edwards ball valve prosthesis implanted in mitral position 31 position years ago [in Japanese]. Kyobu Geka 2003;56:535-40.
    • (2003) Kyobu Geka , vol.56 , pp. 535-540
    • Goshima, M.1    Shiono, M.2    Yamamoto, T.3    Inoue, T.4    Hata, M.5    Sezai, A.6
  • 12
    • 0028914551 scopus 로고
    • Up to thirty-year survival after aortic valve replacement in the small aortic root
    • He GW, Grunkemeier GL, Gately HL, Furnary AP, Starr A. Up to thirty-year survival after aortic valve replacement in the small aortic root. Ann Thorac Surg 1995;59:1056-62.
    • (1995) Ann Thorac Surg , vol.59 , pp. 1056-1062
    • He, G.W.1    Grunkemeier, G.L.2    Gately, H.L.3    Furnary, A.P.4    Starr, A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.