메뉴 건너뛰기




Volumn 12, Issue 1, 2005, Pages 41-49

Cylindrical geometry electroquasistatic dielectrometry sensors

Author keywords

Bessel series; Cylindrical; Dielectrometer; Electroquasistatic; Parameter estimation

Indexed keywords

ANISOTROPY; COMPUTER SIMULATION; ELECTRODES; ELECTROSTATICS; FINITE ELEMENT METHOD; GRAPHIC METHODS; MATHEMATICAL MODELS; PARAMETER ESTIMATION;

EID: 14544300436     PISSN: 10709878     EISSN: None     Source Type: Journal    
DOI: 10.1109/TDEI.2005.1394014     Document Type: Article
Times cited : (11)

References (5)
  • 1
    • 0004196517 scopus 로고    scopus 로고
    • Ph.D. thesis, Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology
    • Y. Sheiretov, Deep Penetration Magnetoquasistatic Sensors, Ph.D. thesis, Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, pp. 48-59, 69-75, 2001.
    • (2001) Deep Penetration Magnetoquasistatic Sensors , pp. 48-59
    • Sheiretov, Y.1
  • 2
    • 0024172332 scopus 로고
    • Continuum properties from interdigital electrode dielectrometry
    • M. C. Zaretsky, L. Mouayad and J. R. Melcher, "Continuum Properties from Interdigital Electrode Dielectrometry", IEEE Trans. Electr. Insul., Vol. 23, pp. 897-917, 1988.
    • (1988) IEEE Trans. Electr. Insul. , vol.23 , pp. 897-917
    • Zaretsky, M.C.1    Mouayad, L.2    Melcher, J.R.3
  • 5
    • 14544280870 scopus 로고    scopus 로고
    • "Apparatus and Methods for Obtaining Increased Sensitivity, Selectivity, and Dynamic Range in Property Measurements Using Magnetometers", US patent number 5,629,621
    • N. J. Goldfine and J. R. Melcher, "Apparatus and Methods for Obtaining Increased Sensitivity, Selectivity, and Dynamic Range in Property Measurements Using Magnetometers", US patent number 5,629,621, 1997.
    • (1997)
    • Goldfine, N.J.1    Melcher, J.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.