메뉴 건너뛰기




Volumn 229, Issue 3-4, 2005, Pages 339-347

Calculation of photoneutrons produced in the targets of electron linear accelerators for radiography and radiotherapy applications

Author keywords

Accelerator target; FLUKA code; Neutron energy spectrum; Photoneutron

Indexed keywords

COMPUTER SIMULATION; ELECTRON BEAMS; ELECTRON ENERGY LEVELS; LINEAR ACCELERATORS; MONTE CARLO METHODS; OPTIMIZATION; RADIOGRAPHY; RADIOTHERAPY; TARGETS; X RAY ANALYSIS;

EID: 14544275903     PISSN: 0168583X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.nimb.2004.12.117     Document Type: Article
Times cited : (43)

References (10)
  • 1
    • 14544297923 scopus 로고    scopus 로고
    • Industrial CT Technique(VI)
    • P. Ni, and X. Li Industrial CT Technique(VI) NDT 18 6 1996
    • (1996) NDT , vol.18 , Issue.6
    • Ni, P.1    Li, X.2
  • 2
    • 0003511916 scopus 로고
    • Neutron contamination from medical accelerators
    • NCRP Report 79, Neutron contamination from medical accelerators, 1984
    • (1984) NCRP Report , vol.79
  • 3
    • 0041025469 scopus 로고    scopus 로고
    • Induced activity of a tungsten target in a 10 MeV electron accelerator
    • Y.G. Teterev, and A.G. Belov Induced activity of a tungsten target in a 10 MeV electron accelerator Atomic Energy 91 3 2001 745
    • (2001) Atomic Energy , vol.91 , Issue.3 , pp. 745
    • Teterev, Y.G.1    Belov, A.G.2
  • 4
    • 85027424652 scopus 로고    scopus 로고
    • Neutron source strength measurements for Varian, Siemens, Elekta and General Electric Linear Accelerators
    • D.S. Followill, M.S. Stovall, S.F. Kry, and G.S. Ibbott Neutron source strength measurements for Varian, Siemens, Elekta and General Electric Linear Accelerators J. Appl. Clin. Med. Phys. 4 2003 189
    • (2003) J. Appl. Clin. Med. Phys. , vol.4 , pp. 189
    • Followill, D.S.1    Stovall, M.S.2    Kry, S.F.3    Ibbott, G.S.4
  • 7
    • 0024405742 scopus 로고
    • Neutron contamination of X-ray beams produced by the Varian clinac 1800
    • P.H. McGinley, and J.C. Landry Neutron contamination of X-ray beams produced by the Varian clinac 1800 Phys. Med. Biol. 34 6 1989 777
    • (1989) Phys. Med. Biol. , vol.34 , Issue.6 , pp. 777
    • McGinley, P.H.1    Landry, J.C.2
  • 8
    • 0020354995 scopus 로고
    • Phosphorus activation neutron dosimetry and its application to an 18-MV radiotherapy accelerator
    • J.R. Bading, and L. Zeitz Phosphorus activation neutron dosimetry and its application to an 18-MV radiotherapy accelerator Med. Phys. 9 6 1982 835
    • (1982) Med. Phys. , vol.9 , Issue.6 , pp. 835
    • Bading, J.R.1    Zeitz, L.2
  • 9
    • 0028832963 scopus 로고
    • Photoneutrons from high energy medical linear accelerators: Measurement of the spectrum and dose using a miniature proportional counter
    • P. Kliauga, and H. Amols Photoneutrons from high energy medical linear accelerators: measurement of the spectrum and dose using a miniature proportional counter Int. J. Radiat. Oncol. Biol. Phys. 31 3 1995 629
    • (1995) Int. J. Radiat. Oncol. Biol. Phys. , vol.31 , Issue.3 , pp. 629
    • Kliauga, P.1    Amols, H.2
  • 10
    • 0041387389 scopus 로고    scopus 로고
    • Photonuclear dose calculations for high-energy photon beams from Siemens and Varian linacs
    • O. Chibani, and C. Ma Photonuclear dose calculations for high-energy photon beams from Siemens and Varian linacs Med. Phys. 30 8 2003 1990
    • (2003) Med. Phys. , vol.30 , Issue.8 , pp. 1990
    • Chibani, O.1    Ma, C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.