메뉴 건너뛰기




Volumn 125, Issue 1, 2005, Pages 16-20

Intraoperative cutting errors in total knee arthroplasty

Author keywords

Computer assisted technique; Cutting error; Total knee arthroplasty

Indexed keywords

ADULT; AGED; ARTICLE; AWARENESS; CLINICAL ARTICLE; COMPUTER ASSISTED SURGERY; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; FEMALE; FEMUR; HUMAN; KNEE FUNCTION; MALE; MEDICAL INSTRUMENTATION; PRIORITY JOURNAL; PROSTHESIS FIXATION; STATISTICAL SIGNIFICANCE; SURGEON; SURGICAL ERROR; SURGICAL TECHNIQUE; TIBIA; TOTAL KNEE REPLACEMENT; VALGUS KNEE; VARUS KNEE;

EID: 14544272041     PISSN: 09368051     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00402-004-0759-1     Document Type: Article
Times cited : (76)

References (20)
  • 1
    • 2142825754 scopus 로고    scopus 로고
    • Radiological results of image-based and non-image-based computer-assisted total knee arthroplasty
    • 10.1007/s00264-003-0533-y
    • Bathis H, Perlick L, Tingart M, Luring C, Perlick C, Grifka J (2004) Radiological results of image-based and non-image-based computer-assisted total knee arthroplasty. Int Orthop 28:87-90. 10.1007/ s00264-003-0533-y
    • (2004) Int. Orthop. , vol.28 , pp. 87-90
    • Bathis, H.1    Perlick, L.2    Tingart, M.3    Luring, C.4    Perlick, C.5    Grifka, J.6
  • 2
    • 0026096567 scopus 로고
    • A comparison of intramedullary and extramedullary alignment systems for tibial component placement in total knee arthroplasty
    • 1993372
    • Brys DA, Lombardi AV Jr, Mallory TH, Vaughn BK (1991) A comparison of intramedullary and extramedullary alignment systems for tibial component placement in total knee arthroplasty. Clin Orthop 263:175-179. 1993372
    • (1991) Clin. Orthop. , vol.263 , pp. 175-179
    • Brys, D.A.1    Lombardi Jr., A.V.2    Mallory, T.H.3    Vaughn, B.K.4
  • 3
    • 12144264364 scopus 로고    scopus 로고
    • Evaluation of image guided surgery systems
    • Department of Health UK Official report of the 'Medicines and Healthcare Products Regulatory Agency', MDA 01025
    • Department of Health UK (2002) Evaluation of image guided surgery systems. Official report of the 'Medicines and Healthcare Products Regulatory Agency', MDA 01025
    • (2002)
  • 4
    • 0025856476 scopus 로고
    • Coronal alignment after total knee replacement
    • 1:STN:280:By6A2szktVw%3D
    • Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73:709-714. 1:STN:280:By6A2szktVw%3D
    • (1991) J. Bone Joint Surg. Br. , vol.73 , pp. 709-714
    • Jeffery, R.S.1    Morris, R.W.2    Denham, R.A.3
  • 5
    • 0034951465 scopus 로고    scopus 로고
    • The Genesis total knee prosthesis: A 10-year followup study
    • 11451138
    • Laskin RS (2001) The Genesis total knee prosthesis: A 10-year followup study. Clin Orthop 388:95-102. 11451138
    • (2001) Clin. Orthop. , vol.388 , pp. 95-102
    • Laskin, R.S.1
  • 6
    • 0023855420 scopus 로고
    • The effects of inaccurate bone cuts on femoral component position in total knee arthroplast
    • 1:STN:280:BieC1cbpt1A%3D
    • Lennox DW, Cohn BT, Eschenroeder HC Jr (1988) The effects of inaccurate bone cuts on femoral component position in total knee arthroplasty. Orthopedics 11:257-260. 1:STN:280:BieC1cbpt1A%3D
    • (1988) Orthopedics , vol.11 , pp. 257-260
    • Lennox, D.W.1    Cohn, B.T.2    Eschenroeder Jr., H.C.3
  • 7
    • 0017353885 scopus 로고
    • Influence of positioning of prosthesis in total knee replacement
    • 1:STN:280:CSiD1MzptFc%3D
    • Lotke PA, Ecker ML (1977) Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg Am 59:77-79. 1:STN:280:CSiD1MzptFc%3D
    • (1977) J. Bone Joint Surg. Am. , vol.59 , pp. 77-79
    • Lotke, P.A.1    Ecker, M.L.2
  • 8
    • 0034880976 scopus 로고    scopus 로고
    • The effect of surgeon experience on component positioning in 673 press fit condylar posterior cruciate-sacrificing total knee arthroplasties
    • 10.1054/arth.2001.23569
    • Mahaluxmivala J, Bankes MJ, Nicolai P, Aldam CH, Allen PW (2001) The effect of surgeon experience on component positioning in 673 press fit condylar posterior cruciate-sacrificing total knee arthroplasties. J Arthroplasty 16:635-640. 10.1054/arth.2001.23569
    • (2001) J. Arthroplasty , vol.16 , pp. 635-640
    • Mahaluxmivala, J.1    Bankes, M.J.2    Nicolai, P.3    Aldam, C.H.4    Allen, P.W.5
  • 9
    • 0035379922 scopus 로고    scopus 로고
    • Effect of femoral and tibial component position on patellar tracking following total knee arthroplasty: 10-year follow-up of Miller-Galante I knees
    • 1:STN:280:DC%2BD3MvksFWgsQ%3D%3D
    • Matsuda S, Miura H, Nagamine R, Urabe K, Hirata G, Iwamoto Y (2001) Effect of femoral and tibial component position on patellar tracking following total knee arthroplasty: 10-year follow-up of Miller-Galante I knees. Am J Knee Surg 14:152-156. 1:STN:280:DC%2BD3MvksFWgsQ%3D%3D
    • (2001) Am. J. Knee Surg. , vol.14 , pp. 152-156
    • Matsuda, S.1    Miura, H.2    Nagamine, R.3    Urabe, K.4    Hirata, G.5    Iwamoto, Y.6
  • 10
    • 0026659381 scopus 로고
    • Surgical instrument design for the accurate cutting of bone for implant fixation
    • 1:STN:280:By2K3c7mvFA%3D
    • Minns RJ (1992) Surgical instrument design for the accurate cutting of bone for implant fixation. Clin Mater 10:207-212. 1:STN:280:By2K3c7mvFA%3D
    • (1992) Clin. Mater. , vol.10 , pp. 207-212
    • Minns, R.J.1
  • 11
    • 0031543723 scopus 로고    scopus 로고
    • Intramedullary goniometer can improve alignment in knee arthroplasty surgery
    • 10.1016/S0883-5403(97)90031-0
    • Mont MA, Urquhart MA, Hungerford DS, Krackow KA (1997) Intramedullary goniometer can improve alignment in knee arthroplasty surgery. J Arthroplasty 12:332-336. 10.1016/S0883-5403(97)90031-0
    • (1997) J. Arthroplasty , vol.12 , pp. 332-336
    • Mont, M.A.1    Urquhart, M.A.2    Hungerford, D.S.3    Krackow, K.A.4
  • 12
    • 0027443705 scopus 로고
    • Cutting errors in preparation of femoral components in total knee arthroplasty
    • 1:STN:280:ByuD28rotlY%3D
    • Otani T, Whiteside LA, White SE (1993) Cutting errors in preparation of femoral components in total knee arthroplasty. J Arthroplasty 8:503-510. 1:STN:280:ByuD28rotlY%3D
    • (1993) J. Arthroplasty , vol.8 , pp. 503-510
    • Otani, T.1    Whiteside, L.A.2    White, S.E.3
  • 13
    • 0023893141 scopus 로고
    • Radiographic assessment of knee alignment after total knee arthroplasty
    • 1:STN:280:BieC1MbmtFQ%3D
    • Petersen TL, Engh GA (1988) Radiographic assessment of knee alignment after total knee arthroplasty. J Arthroplasty 3:67-72. 1:STN:280:BieC1MbmtFQ%3D
    • (1988) J. Arthroplasty , vol.3 , pp. 67-72
    • Petersen, T.L.1    Engh, G.A.2
  • 14
    • 0036714796 scopus 로고    scopus 로고
    • Bone cutting errors in total knee arthroplasty
    • 10.1054/arth.2002.33564
    • Plaskos C, Hodgson AJ, Inkpen K, McGraw RW (2002) Bone cutting errors in total knee arthroplasty. J Arthroplasty 17:698-705. 10.1054/ arth.2002.33564
    • (2002) J. Arthroplasty , vol.17 , pp. 698-705
    • Plaskos, C.1    Hodgson, A.J.2    Inkpen, K.3    McGraw, R.W.4
  • 15
    • 0030869964 scopus 로고    scopus 로고
    • The accuracy of femoral intramedullary guides in total knee arthroplasty
    • 10.1016/S0883-5403(97)90141-8
    • Reed SC, Gollish J (1997) The accuracy of femoral intramedullary guides in total knee arthroplasty. J Arthroplasty 12:677-682. 10.1016/ S0883-5403(97)90141-8
    • (1997) J. Arthroplasty , vol.12 , pp. 677-682
    • Reed, S.C.1    Gollish, J.2
  • 16
    • 0028044658 scopus 로고
    • Postoperative alignment of total knee replacement. Its effect on survival
    • 8119010
    • Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop 299:153-156. 8119010
    • (1994) Clin. Orthop. , vol.299 , pp. 153-156
    • Ritter, M.A.1    Faris, P.M.2    Keating, E.M.3    Meding, J.B.4
  • 17
    • 0034950717 scopus 로고    scopus 로고
    • Total condylar knee replacement: A 20-year followup study
    • 10.1097/00003086-200107000-00004
    • Rodriguez JA, Bhende H, Ranawat CS (2001) Total condylar knee replacement: A 20-year followup study. Clin Orthop 388:10-17. 10.1097/ 00003086-200107000-00004
    • (2001) Clin. Orthop. , vol.388 , pp. 10-17
    • Rodriguez, J.A.1    Bhende, H.2    Ranawat, C.S.3
  • 18
    • 0023712371 scopus 로고
    • Results after knee replacement with a posterior cruciate-substituting prosthesis
    • 1:STN:280:BieA3s%2FpsFA%3D
    • Scott WN, Rubinstein M, Scuderi G (1988) Results after knee replacement with a posterior cruciate-substituting prosthesis. J Bone Joint Surg Am 70:1163-1173. 1:STN:280:BieA3s%2FpsFA%3D
    • (1988) J. Bone Joint Surg. Am. , vol.70 , pp. 1163-1173
    • Scott, W.N.1    Rubinstein, M.2    Scuderi, G.3
  • 19
    • 0043030086 scopus 로고    scopus 로고
    • Positioning of total knee arthroplasty with and without navigation support. A prospective, randomised study
    • 1:STN:280:DC%2BD3szpsVGjtg%3D%3D
    • Sparmann M, Wolke B, Czupalla H, Banzer D, Zink A (2003) Positioning of total knee arthroplasty with and without navigation support. A prospective, randomised study. J Bone Joint Surg Br 85:830-835. 1:STN:280:DC%2BD3szpsVGjtg%3D%3D
    • (2003) J. Bone Joint Surg. Br. , vol.85 , pp. 830-835
    • Sparmann, M.1    Wolke, B.2    Czupalla, H.3    Banzer, D.4    Zink, A.5
  • 20
    • 0028839546 scopus 로고
    • Accuracy of intramedullary versus extramedullary tibial alignment cutting systems in total knee arthroplasty
    • 7497654
    • Teter KE, Bregman D, Colwell CW Jr (1995) Accuracy of intramedullary versus extramedullary tibial alignment cutting systems in total knee arthroplasty. Clin Orthop 321:106-110. 7497654
    • (1995) Clin. Orthop. , vol.321 , pp. 106-110
    • Teter, K.E.1    Bregman, D.2    Colwell Jr., C.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.