-
1
-
-
2142825754
-
Radiological results of image-based and non-image-based computer-assisted total knee arthroplasty
-
10.1007/s00264-003-0533-y
-
Bathis H, Perlick L, Tingart M, Luring C, Perlick C, Grifka J (2004) Radiological results of image-based and non-image-based computer-assisted total knee arthroplasty. Int Orthop 28:87-90. 10.1007/ s00264-003-0533-y
-
(2004)
Int. Orthop.
, vol.28
, pp. 87-90
-
-
Bathis, H.1
Perlick, L.2
Tingart, M.3
Luring, C.4
Perlick, C.5
Grifka, J.6
-
2
-
-
0026096567
-
A comparison of intramedullary and extramedullary alignment systems for tibial component placement in total knee arthroplasty
-
1993372
-
Brys DA, Lombardi AV Jr, Mallory TH, Vaughn BK (1991) A comparison of intramedullary and extramedullary alignment systems for tibial component placement in total knee arthroplasty. Clin Orthop 263:175-179. 1993372
-
(1991)
Clin. Orthop.
, vol.263
, pp. 175-179
-
-
Brys, D.A.1
Lombardi Jr., A.V.2
Mallory, T.H.3
Vaughn, B.K.4
-
3
-
-
12144264364
-
Evaluation of image guided surgery systems
-
Department of Health UK Official report of the 'Medicines and Healthcare Products Regulatory Agency', MDA 01025
-
Department of Health UK (2002) Evaluation of image guided surgery systems. Official report of the 'Medicines and Healthcare Products Regulatory Agency', MDA 01025
-
(2002)
-
-
-
4
-
-
0025856476
-
Coronal alignment after total knee replacement
-
1:STN:280:By6A2szktVw%3D
-
Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73:709-714. 1:STN:280:By6A2szktVw%3D
-
(1991)
J. Bone Joint Surg. Br.
, vol.73
, pp. 709-714
-
-
Jeffery, R.S.1
Morris, R.W.2
Denham, R.A.3
-
5
-
-
0034951465
-
The Genesis total knee prosthesis: A 10-year followup study
-
11451138
-
Laskin RS (2001) The Genesis total knee prosthesis: A 10-year followup study. Clin Orthop 388:95-102. 11451138
-
(2001)
Clin. Orthop.
, vol.388
, pp. 95-102
-
-
Laskin, R.S.1
-
6
-
-
0023855420
-
The effects of inaccurate bone cuts on femoral component position in total knee arthroplast
-
1:STN:280:BieC1cbpt1A%3D
-
Lennox DW, Cohn BT, Eschenroeder HC Jr (1988) The effects of inaccurate bone cuts on femoral component position in total knee arthroplasty. Orthopedics 11:257-260. 1:STN:280:BieC1cbpt1A%3D
-
(1988)
Orthopedics
, vol.11
, pp. 257-260
-
-
Lennox, D.W.1
Cohn, B.T.2
Eschenroeder Jr., H.C.3
-
7
-
-
0017353885
-
Influence of positioning of prosthesis in total knee replacement
-
1:STN:280:CSiD1MzptFc%3D
-
Lotke PA, Ecker ML (1977) Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg Am 59:77-79. 1:STN:280:CSiD1MzptFc%3D
-
(1977)
J. Bone Joint Surg. Am.
, vol.59
, pp. 77-79
-
-
Lotke, P.A.1
Ecker, M.L.2
-
8
-
-
0034880976
-
The effect of surgeon experience on component positioning in 673 press fit condylar posterior cruciate-sacrificing total knee arthroplasties
-
10.1054/arth.2001.23569
-
Mahaluxmivala J, Bankes MJ, Nicolai P, Aldam CH, Allen PW (2001) The effect of surgeon experience on component positioning in 673 press fit condylar posterior cruciate-sacrificing total knee arthroplasties. J Arthroplasty 16:635-640. 10.1054/arth.2001.23569
-
(2001)
J. Arthroplasty
, vol.16
, pp. 635-640
-
-
Mahaluxmivala, J.1
Bankes, M.J.2
Nicolai, P.3
Aldam, C.H.4
Allen, P.W.5
-
9
-
-
0035379922
-
Effect of femoral and tibial component position on patellar tracking following total knee arthroplasty: 10-year follow-up of Miller-Galante I knees
-
1:STN:280:DC%2BD3MvksFWgsQ%3D%3D
-
Matsuda S, Miura H, Nagamine R, Urabe K, Hirata G, Iwamoto Y (2001) Effect of femoral and tibial component position on patellar tracking following total knee arthroplasty: 10-year follow-up of Miller-Galante I knees. Am J Knee Surg 14:152-156. 1:STN:280:DC%2BD3MvksFWgsQ%3D%3D
-
(2001)
Am. J. Knee Surg.
, vol.14
, pp. 152-156
-
-
Matsuda, S.1
Miura, H.2
Nagamine, R.3
Urabe, K.4
Hirata, G.5
Iwamoto, Y.6
-
10
-
-
0026659381
-
Surgical instrument design for the accurate cutting of bone for implant fixation
-
1:STN:280:By2K3c7mvFA%3D
-
Minns RJ (1992) Surgical instrument design for the accurate cutting of bone for implant fixation. Clin Mater 10:207-212. 1:STN:280:By2K3c7mvFA%3D
-
(1992)
Clin. Mater.
, vol.10
, pp. 207-212
-
-
Minns, R.J.1
-
11
-
-
0031543723
-
Intramedullary goniometer can improve alignment in knee arthroplasty surgery
-
10.1016/S0883-5403(97)90031-0
-
Mont MA, Urquhart MA, Hungerford DS, Krackow KA (1997) Intramedullary goniometer can improve alignment in knee arthroplasty surgery. J Arthroplasty 12:332-336. 10.1016/S0883-5403(97)90031-0
-
(1997)
J. Arthroplasty
, vol.12
, pp. 332-336
-
-
Mont, M.A.1
Urquhart, M.A.2
Hungerford, D.S.3
Krackow, K.A.4
-
12
-
-
0027443705
-
Cutting errors in preparation of femoral components in total knee arthroplasty
-
1:STN:280:ByuD28rotlY%3D
-
Otani T, Whiteside LA, White SE (1993) Cutting errors in preparation of femoral components in total knee arthroplasty. J Arthroplasty 8:503-510. 1:STN:280:ByuD28rotlY%3D
-
(1993)
J. Arthroplasty
, vol.8
, pp. 503-510
-
-
Otani, T.1
Whiteside, L.A.2
White, S.E.3
-
13
-
-
0023893141
-
Radiographic assessment of knee alignment after total knee arthroplasty
-
1:STN:280:BieC1MbmtFQ%3D
-
Petersen TL, Engh GA (1988) Radiographic assessment of knee alignment after total knee arthroplasty. J Arthroplasty 3:67-72. 1:STN:280:BieC1MbmtFQ%3D
-
(1988)
J. Arthroplasty
, vol.3
, pp. 67-72
-
-
Petersen, T.L.1
Engh, G.A.2
-
14
-
-
0036714796
-
Bone cutting errors in total knee arthroplasty
-
10.1054/arth.2002.33564
-
Plaskos C, Hodgson AJ, Inkpen K, McGraw RW (2002) Bone cutting errors in total knee arthroplasty. J Arthroplasty 17:698-705. 10.1054/ arth.2002.33564
-
(2002)
J. Arthroplasty
, vol.17
, pp. 698-705
-
-
Plaskos, C.1
Hodgson, A.J.2
Inkpen, K.3
McGraw, R.W.4
-
15
-
-
0030869964
-
The accuracy of femoral intramedullary guides in total knee arthroplasty
-
10.1016/S0883-5403(97)90141-8
-
Reed SC, Gollish J (1997) The accuracy of femoral intramedullary guides in total knee arthroplasty. J Arthroplasty 12:677-682. 10.1016/ S0883-5403(97)90141-8
-
(1997)
J. Arthroplasty
, vol.12
, pp. 677-682
-
-
Reed, S.C.1
Gollish, J.2
-
16
-
-
0028044658
-
Postoperative alignment of total knee replacement. Its effect on survival
-
8119010
-
Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop 299:153-156. 8119010
-
(1994)
Clin. Orthop.
, vol.299
, pp. 153-156
-
-
Ritter, M.A.1
Faris, P.M.2
Keating, E.M.3
Meding, J.B.4
-
17
-
-
0034950717
-
Total condylar knee replacement: A 20-year followup study
-
10.1097/00003086-200107000-00004
-
Rodriguez JA, Bhende H, Ranawat CS (2001) Total condylar knee replacement: A 20-year followup study. Clin Orthop 388:10-17. 10.1097/ 00003086-200107000-00004
-
(2001)
Clin. Orthop.
, vol.388
, pp. 10-17
-
-
Rodriguez, J.A.1
Bhende, H.2
Ranawat, C.S.3
-
18
-
-
0023712371
-
Results after knee replacement with a posterior cruciate-substituting prosthesis
-
1:STN:280:BieA3s%2FpsFA%3D
-
Scott WN, Rubinstein M, Scuderi G (1988) Results after knee replacement with a posterior cruciate-substituting prosthesis. J Bone Joint Surg Am 70:1163-1173. 1:STN:280:BieA3s%2FpsFA%3D
-
(1988)
J. Bone Joint Surg. Am.
, vol.70
, pp. 1163-1173
-
-
Scott, W.N.1
Rubinstein, M.2
Scuderi, G.3
-
19
-
-
0043030086
-
Positioning of total knee arthroplasty with and without navigation support. A prospective, randomised study
-
1:STN:280:DC%2BD3szpsVGjtg%3D%3D
-
Sparmann M, Wolke B, Czupalla H, Banzer D, Zink A (2003) Positioning of total knee arthroplasty with and without navigation support. A prospective, randomised study. J Bone Joint Surg Br 85:830-835. 1:STN:280:DC%2BD3szpsVGjtg%3D%3D
-
(2003)
J. Bone Joint Surg. Br.
, vol.85
, pp. 830-835
-
-
Sparmann, M.1
Wolke, B.2
Czupalla, H.3
Banzer, D.4
Zink, A.5
-
20
-
-
0028839546
-
Accuracy of intramedullary versus extramedullary tibial alignment cutting systems in total knee arthroplasty
-
7497654
-
Teter KE, Bregman D, Colwell CW Jr (1995) Accuracy of intramedullary versus extramedullary tibial alignment cutting systems in total knee arthroplasty. Clin Orthop 321:106-110. 7497654
-
(1995)
Clin. Orthop.
, vol.321
, pp. 106-110
-
-
Teter, K.E.1
Bregman, D.2
Colwell Jr., C.W.3
|