메뉴 건너뛰기




Volumn 35, Issue 3, 2004, Pages 687-693

Comparison of Transcranial Brain Tissue Perfusion Images between Ultraharmonic, Second Harmonic, and Power Harmonic Imaging

Author keywords

Contrast media; Imaging techniques; Perfusion, brain; Ultrasonography, Doppler, color, transcranial

Indexed keywords

CONTRAST MEDIUM; SHU 508;

EID: 1442348269     PISSN: 00392499     EISSN: None     Source Type: Journal    
DOI: 10.1161/01.STR.0000116102.15636.65     Document Type: Article
Times cited : (13)

References (27)
  • 1
    • 0031663434 scopus 로고    scopus 로고
    • Transient response harmonic imaging: An ultrasound technique related to brain perfusion
    • Postert T, Muhs A, Meves S, Federlein J, Przuntek H, Buttner T. Transient response harmonic imaging: an ultrasound technique related to brain perfusion. Stroke. 1998;29:1901-1907.
    • (1998) Stroke , vol.29 , pp. 1901-1907
    • Postert, T.1    Muhs, A.2    Meves, S.3    Federlein, J.4    Przuntek, H.5    Buttner, T.6
  • 3
    • 0033805369 scopus 로고    scopus 로고
    • Ultrasound perfusion imaging of the human brain
    • Wiesmann M, Seidel G. Ultrasound perfusion imaging of the human brain. Stroke. 2000;31:2421-2425.
    • (2000) Stroke , vol.31 , pp. 2421-2425
    • Wiesmann, M.1    Seidel, G.2
  • 4
    • 0032776886 scopus 로고    scopus 로고
    • Second harmonic imaging in acute middle cerebral artery infarction: Preliminary results
    • Postert T, Federlein J, Weber S, Przuntek H, Buttner T. Second harmonic imaging in acute middle cerebral artery infarction: preliminary results. Stroke. 1999;30:1702-1706.
    • (1999) Stroke , vol.30 , pp. 1702-1706
    • Postert, T.1    Federlein, J.2    Weber, S.3    Przuntek, H.4    Buttner, T.5
  • 5
    • 0034639663 scopus 로고    scopus 로고
    • Pulse-inversion contrast harmonic imaging: Ultrasonographic assessment of cerebral perfusion
    • Meairs S, Daffertshofer M, Neff W, Eschenfelder C, Hennerici M. Pulse-inversion contrast harmonic imaging: ultrasonographic assessment of cerebral perfusion. Lancet. 2000;355:550-551.
    • (2000) Lancet , vol.355 , pp. 550-551
    • Meairs, S.1    Daffertshofer, M.2    Neff, W.3    Eschenfelder, C.4    Hennerici, M.5
  • 7
    • 0035059141 scopus 로고    scopus 로고
    • Sonographic parenchymal and brain perfusion imaging: Preliminary results in four patients following decompressive surgery for malignant middle cerebral artery infarct
    • Schlachetzki F, Hoelscher T, Dorenbeck U, Greiffenberg B, Marienhagen J, Ullrich OW, Bogdahn U. Sonographic parenchymal and brain perfusion imaging: preliminary results in four patients following decompressive surgery for malignant middle cerebral artery infarct. Ultrasound Med Biol. 2001;27:21-31.
    • (2001) Ultrasound Med Biol , vol.27 , pp. 21-31
    • Schlachetzki, F.1    Hoelscher, T.2    Dorenbeck, U.3    Greiffenberg, B.4    Marienhagen, J.5    Ullrich, O.W.6    Bogdahn, U.7
  • 8
    • 0344211856 scopus 로고    scopus 로고
    • Harmonic imaging in acute stroke: Detection of a cerebral perfusion deficit with ultrasound and perfusion MRI
    • Meyer K, Wiesmann M, Albers T, Seidel G. Harmonic imaging in acute stroke: detection of a cerebral perfusion deficit with ultrasound and perfusion MRI. J Neuroimaging. 2003;13:166-168.
    • (2003) J Neuroimaging , vol.13 , pp. 166-168
    • Meyer, K.1    Wiesmann, M.2    Albers, T.3    Seidel, G.4
  • 9
    • 0036450024 scopus 로고    scopus 로고
    • Acetazolamide vasoreactivity in vascular dementia and persistent vegetative state evaluated by transcranial harmonic perfusion imaging and Doppler sonography
    • Shiogai T, Uebo C, Makino M, Mizuno T, Nakajima K, Furuhata H. Acetazolamide vasoreactivity in vascular dementia and persistent vegetative state evaluated by transcranial harmonic perfusion imaging and Doppler sonography. Ann N Y Acad Sci. 2002;977:445-453.
    • (2002) Ann N Y Acad Sci , vol.977 , pp. 445-453
    • Shiogai, T.1    Uebo, C.2    Makino, M.3    Mizuno, T.4    Nakajima, K.5    Furuhata, H.6
  • 10
    • 0001778585 scopus 로고    scopus 로고
    • Physics of microbubble scattering
    • Nanda NC, Schlief R, Goldberg BB, eds. Dubai, Saudi Arabia: Kluwer Academic Publishers
    • De Jong N. Physics of microbubble scattering. In: Nanda NC, Schlief R, Goldberg BB, eds. Advances in Echo Imaging Using Contrast Enhancement. 2nd ed. Dubai, Saudi Arabia: Kluwer Academic Publishers; 1997:39-64.
    • (1997) Advances in Echo Imaging Using Contrast Enhancement. 2nd Ed. , pp. 39-64
    • De Jong, N.1
  • 12
    • 0029830664 scopus 로고    scopus 로고
    • Analysis of regional cerebral blood flow in dogs, with an experimental microbubble-based US contrast agent
    • Greenberg RS, Taylor GA, Stapleton JC, Hillsley CA, Spinak D. Analysis of regional cerebral blood flow in dogs, with an experimental microbubble-based US contrast agent. Radiology. 1996;201:119-123.
    • (1996) Radiology , vol.201 , pp. 119-123
    • Greenberg, R.S.1    Taylor, G.A.2    Stapleton, J.C.3    Hillsley, C.A.4    Spinak, D.5
  • 13
    • 0036102269 scopus 로고    scopus 로고
    • Instrumentation for contrast echocardiography
    • Burns PN. Instrumentation for contrast echocardiography. Echocardiography. 2002;19:241-258.
    • (2002) Echocardiography , vol.19 , pp. 241-258
    • Burns, P.N.1
  • 14
    • 0033918894 scopus 로고    scopus 로고
    • Stimulated acoustic emission detected by transcranial color Doppler ultrasound: A contrast-specific phenomenon useful for the detection of cerebral tissue perfusion
    • Pohl C, Tiemann K, Schlosser T, Becher H. Stimulated acoustic emission detected by transcranial color Doppler ultrasound: a contrast-specific phenomenon useful for the detection of cerebral tissue perfusion. Stroke. 2000;31:1661-1666.
    • (2000) Stroke , vol.31 , pp. 1661-1666
    • Pohl, C.1    Tiemann, K.2    Schlosser, T.3    Becher, H.4
  • 16
    • 0033945092 scopus 로고    scopus 로고
    • Visualization of brain perfusion with harmonic gray scale and power Doppler technology: An animal pilot study
    • Seidel G, Algermissen C, Christoph A, Katzer T, Kaps M. Visualization of brain perfusion with harmonic gray scale and power Doppler technology: an animal pilot study. Stroke. 2000;31:1728-1734.
    • (2000) Stroke , vol.31 , pp. 1728-1734
    • Seidel, G.1    Algermissen, C.2    Christoph, A.3    Katzer, T.4    Kaps, M.5
  • 17
    • 0036143949 scopus 로고    scopus 로고
    • Harmonic imaging of the brain parenchyma in a dog model following NC100100 (Sonazoid) bolus injection
    • Meyer K, Seidel G, Algermissen C. Harmonic imaging of the brain parenchyma in a dog model following NC100100 (Sonazoid) bolus injection. J Neuroimaging. 2002;12:35-41.
    • (2002) J Neuroimaging , vol.12 , pp. 35-41
    • Meyer, K.1    Seidel, G.2    Algermissen, C.3
  • 18
    • 0011962195 scopus 로고    scopus 로고
    • Comparative visualization of brain tissue perfusion in various neurological disorders utilizing contrast-enhanced harmonic imaging in integrated backscatter and power Doppler methods
    • Abstract
    • Shiogai T, Tsunezuka C, Koshimura M, Takayasu N, Nagakane Y, Nakase T, Makino M, Nakajima K, Furuhata H. Comparative visualization of brain tissue perfusion in various neurological disorders utilizing contrast-enhanced harmonic imaging in integrated backscatter and power Doppler methods. Cerebrovasc Dis. 2000;10(suppl 1):44. Abstract.
    • (2000) Cerebrovasc Dis , vol.10 , Issue.SUPPL. 1 , pp. 44
    • Shiogai, T.1    Tsunezuka, C.2    Koshimura, M.3    Takayasu, N.4    Nagakane, Y.5    Nakase, T.6    Makino, M.7    Nakajima, K.8    Furuhata, H.9
  • 20
    • 0003464609 scopus 로고    scopus 로고
    • Coopertino, Calif: Hewlett-Packard Co; white paper
    • D'Sa A. Acoustic Densitometry. Coopertino, Calif: Hewlett-Packard Co; white paper 1999.
    • (1999) Acoustic Densitometry
    • D'Sa, A.1
  • 23
    • 0035943072 scopus 로고    scopus 로고
    • Destruction of contrast microbubbles by ultrasound: Effects on myocardial function, coronary perfusion pressure, and microvascular integrity
    • Ay T, Havaux X, Van Camp G, Campanelli B, Gisellu G, Pasquet A, Denef JF, Melin JA, Vanoverschelde JL. Destruction of contrast microbubbles by ultrasound: effects on myocardial function, coronary perfusion pressure, and microvascular integrity. Circulation. 2001;104:461-416.
    • (2001) Circulation , vol.104 , pp. 461-416
    • Ay, T.1    Havaux, X.2    Van Camp, G.3    Campanelli, B.4    Gisellu, G.5    Pasquet, A.6    Denef, J.F.7    Melin, J.A.8    Vanoverschelde, J.L.9
  • 24
    • 0017964432 scopus 로고
    • Acoustical properties of the human skull
    • Fry FJ, Barger JE. Acoustical properties of the human skull. JAcoust Soc Am. 1978;63:1576-1590.
    • (1978) JAcoust Soc Am , vol.63 , pp. 1576-1590
    • Fry, F.J.1    Barger, J.E.2
  • 27
    • 0033043008 scopus 로고    scopus 로고
    • Subharmonic generation from ultrasonic contrast agents
    • Krishna PD, Shankar PM, Newhouse VL. Subharmonic generation from ultrasonic contrast agents. Phys Med Biol. 1999;44:681-694.
    • (1999) Phys Med Biol , vol.44 , pp. 681-694
    • Krishna, P.D.1    Shankar, P.M.2    Newhouse, V.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.