메뉴 건너뛰기




Volumn 100, Issue 3, 2004, Pages 534-540

An investigation of structural degradation of cerebrospinal fluid shunt valves performed using scanning electron microscopy and energy-dispersive x-ray microanalysis

Author keywords

Cerebrospinal fluid shunt; Hydrocephalus; Scanning electron microscopy; Valve

Indexed keywords

CALCIUM; CARBON; SODIUM CHLORIDE;

EID: 1442282484     PISSN: 00223085     EISSN: None     Source Type: Journal    
DOI: 10.3171/jns.2004.100.3.0534     Document Type: Article
Times cited : (16)

References (19)
  • 1
    • 0028913470 scopus 로고
    • Overdrainage and shunt technology. A critical comparison of programmable, hydrostatic and variable-resistance valves and flow-reducing devices
    • Aschoff A, Kremer P, Benesch C, et al: Overdrainage and shunt technology. A critical comparison of programmable, hydrostatic and variable-resistance valves and flow-reducing devices. Childs Nerv Syst 11:193-202, 1995
    • (1995) Childs Nerv Syst , vol.11 , pp. 193-202
    • Aschoff, A.1    Kremer, P.2    Benesch, C.3
  • 2
    • 0028362577 scopus 로고
    • Production of extracellular slime by coryneforms colonizing hydrocephalic shunts
    • Bayston R, Compton C, Richards K: Production of extracellular slime by coryneforms colonizing hydrocephalic shunts. J Clin Microbiol 32:1705-1709, 1994
    • (1994) J Clin Microbiol , vol.32 , pp. 1705-1709
    • Bayston, R.1    Compton, C.2    Richards, K.3
  • 3
    • 0031839861 scopus 로고    scopus 로고
    • Mechanical dysfunction of ventriculoperitoneal shunts caused to calcification of the silicone rubber catheter
    • Boch AL, Hermelin E, Sainte-Rose C, et al: Mechanical dysfunction of ventriculoperitoneal shunts caused to calcification of the silicone rubber catheter. J Neurosurg 88:975-982, 1998
    • (1998) J Neurosurg , vol.88 , pp. 975-982
    • Boch, A.L.1    Hermelin, E.2    Sainte-Rose, C.3
  • 4
    • 0029940323 scopus 로고    scopus 로고
    • Removed shunt valves: Reasons for failure and implications for valve design
    • Brydon HL, Bayston R, Hayward R, et al: Removed shunt valves: reasons for failure and implications for valve design. Br J Neurosurg 10:245-251, 1996
    • (1996) Br J Neurosurg , vol.10 , pp. 245-251
    • Brydon, H.L.1    Bayston, R.2    Hayward, R.3
  • 5
    • 0031923504 scopus 로고    scopus 로고
    • Protein absorption to hydrocephalus shunt catheters: CSF protein absorption
    • Brydon HL, Keir G, Thompson EJ, et al: Protein absorption to hydrocephalus shunt catheters: CSF protein absorption. J Neurol Neurosurg Psychiatry 64:643-647, 1998
    • (1998) J Neurol Neurosurg Psychiatry , vol.64 , pp. 643-647
    • Brydon, H.L.1    Keir, G.2    Thompson, E.J.3
  • 6
    • 0017843771 scopus 로고
    • Surface ultra structure of tissues occluding ventricular catheters
    • Collins P, Hockley AD, Woollam DHM: Surface ultra structure of tissues occluding ventricular catheters. J Neurosurg 48:609-613, 1978
    • (1978) J Neurosurg , vol.48 , pp. 609-613
    • Collins, P.1    Hockley, A.D.2    Woollam, D.H.M.3
  • 7
    • 0028876539 scopus 로고
    • Fractures of the peritoneal catheter of cerebrospinal fluid shunts
    • Cuka GM, Hellbusch LC: Fractures of the peritoneal catheter of cerebrospinal fluid shunts. Pediatr Neurosurg 22:101-103, 1995
    • (1995) Pediatr Neurosurg , vol.22 , pp. 101-103
    • Cuka, G.M.1    Hellbusch, L.C.2
  • 8
    • 0028289969 scopus 로고
    • A survey of the first complication of newly implanted CSF shunt devices for the treatment of nontumoral hydrocephalus. Cooperative survey of the 1991-1992 Education Committee of the ISPN
    • Di Rocco C, Marchese E, Velardi F: A survey of the first complication of newly implanted CSF shunt devices for the treatment of nontumoral hydrocephalus. Cooperative survey of the 1991-1992 Education Committee of the ISPN. Childs Nerv Syst 10: 321-327, 1994
    • (1994) Childs Nerv Syst , vol.10 , pp. 321-327
    • Di Rocco, C.1    Marchese, E.2    Velardi, F.3
  • 9
    • 7344257733 scopus 로고    scopus 로고
    • Randomized trial of cerebrospinal fluid shunt valve design in pediatric hydrocephalus
    • Drake JM, Kestle JR, Milner R, et al: Randomized trial of cerebrospinal fluid shunt valve design in pediatric hydrocephalus. Neurosurgery 43:294-305, 1998
    • (1998) Neurosurgery , vol.43 , pp. 294-305
    • Drake, J.M.1    Kestle, J.R.2    Milner, R.3
  • 10
    • 0023280845 scopus 로고
    • Mineralization and biodegradation of CSF shunting systems
    • Echizenya K, Satoh M, Murai H, et al: Mineralization and biodegradation of CSF shunting systems. J Neurosurg 67:584-591, 1987
    • (1987) J Neurosurg , vol.67 , pp. 584-591
    • Echizenya, K.1    Satoh, M.2    Murai, H.3
  • 11
    • 0021749723 scopus 로고
    • Sterile shunt malfunction. A scanning electron microscopic perspective
    • Gower DJ, Lewis JC, Kelly DL Jr: Sterile shunt malfunction. A scanning electron microscopic perspective. J Neurosurg 61: 1079-1084, 1984
    • (1984) J Neurosurg , vol.61 , pp. 1079-1084
    • Gower, D.J.1    Lewis, J.C.2    Kelly Jr., D.L.3
  • 12
    • 0023066114 scopus 로고
    • Calcium deposits on CSF shunts. Clinical observations and ultrastructural analysis
    • Griebel RW, Hoffman HJ, Becker L: Calcium deposits on CSF shunts. Clinical observations and ultrastructural analysis. Childs Nerv Syst 3:180-182, 1987
    • (1987) Childs Nerv Syst , vol.3 , pp. 180-182
    • Griebel, R.W.1    Hoffman, H.J.2    Becker, L.3
  • 13
    • 0019862726 scopus 로고
    • Microscopic studies in shunts for hydrocephalus
    • Guevara JA, Denoya CD, La Torre J, et al: Microscopic studies in shunts for hydrocephalus. Childs Brain 8:284-293, 1981
    • (1981) Childs Brain , vol.8 , pp. 284-293
    • Guevara, J.A.1    Denoya, C.D.2    La Torre, J.3
  • 14
    • 0023199115 scopus 로고
    • Bacterial adhesion to cerebrospinal fluid shunts
    • Guevara JA, Zuccaro G, Trevisan A, et al: Bacterial adhesion to cerebrospinal fluid shunts. J Neurosurg 67:438-445, 1987
    • (1987) J Neurosurg , vol.67 , pp. 438-445
    • Guevara, J.A.1    Zuccaro, G.2    Trevisan, A.3
  • 15
    • 0034063602 scopus 로고    scopus 로고
    • Use of scanning electron microscopy to investigate the prophylactic efficacy of rifampin-impregnated CSF shunt catheters
    • Kockro RA, Hampl JA, Jansen B, et al: Use of scanning electron microscopy to investigate the prophylactic efficacy of rifampin-impregnated CSF shunt catheters. J Med Microbiol 49:441-450, 2000
    • (2000) J Med Microbiol , vol.49 , pp. 441-450
    • Kockro, R.A.1    Hampl, J.A.2    Jansen, B.3
  • 16
    • 0032948821 scopus 로고    scopus 로고
    • Presence of vitronectin and activated complement factor C9 on ventriculoperitoneal shunts and temporary ventricular drainage catheters
    • Lundberg F, Li DQ, Falkenback D, et al: Presence of vitronectin and activated complement factor C9 on ventriculoperitoneal shunts and temporary ventricular drainage catheters. J Neurosurg 90:101-108, 1999
    • (1999) J Neurosurg , vol.90 , pp. 101-108
    • Lundberg, F.1    Li, D.Q.2    Falkenback, D.3
  • 17
    • 0033395387 scopus 로고    scopus 로고
    • New valves - New dangers? 22 Valves (38 probes) designed in the 'nineties in ultra-long-term tests (365 days)'
    • Oikonomou J, Aschoff A, Hashemi B, et al: New valves - new dangers? 22 valves (38 probes) designed in the 'nineties in ultra-long-term tests (365 days)'. Eur J Pediatr Surg 9 (Suppl 1): 23-26, 1999
    • (1999) Eur J Pediatr Surg , vol.9 , Issue.SUPPL. 1 , pp. 23-26
    • Oikonomou, J.1    Aschoff, A.2    Hashemi, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.