메뉴 건너뛰기




Volumn 79, Issue 3, 2005, Pages 796-800

Long-term integrity of teflon felt-supported suture lines in aortic surgery

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; AORTA SINUS; AORTA SURGERY; ARTICLE; ASCENDING AORTA; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; CONFIDENCE INTERVAL; CONTROLLED STUDY; FALSE ANEURYSM; HUMAN; LONGEVITY; PRIORITY JOURNAL; RETROSPECTIVE STUDY; SURGICAL TECHNIQUE; SUTURING METHOD; THORACIC AORTA;

EID: 14244266156     PISSN: 00034975     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.athoracsur.2004.08.028     Document Type: Article
Times cited : (35)

References (12)
  • 2
    • 0030725967 scopus 로고    scopus 로고
    • Reoperations on the aortic root and ascending aorta
    • D. Dougenis, B.B. Daily, N.T. Kouchoukos Reoperations on the aortic root and ascending aorta Ann Thorac Surg 64 1997 986 992
    • (1997) Ann Thorac Surg , vol.64 , pp. 986-992
    • Dougenis, D.1    Daily, B.B.2    Kouchoukos, N.T.3
  • 3
    • 0036839791 scopus 로고    scopus 로고
    • Proximal aortic reoperations in patients with composite valve grafts
    • S.A. LeMaire, D.J. DiBardina, C. Koeksoy, J.S. Coselli Proximal aortic reoperations in patients with composite valve grafts Ann Thorac Surg 74 2002 1777 1780
    • (2002) Ann Thorac Surg , vol.74 , pp. 1777-1780
    • Lemaire, S.A.1    Dibardina, D.J.2    Koeksoy, C.3    Coselli, J.S.4
  • 4
    • 0028067337 scopus 로고
    • Aortic dissection-prevalence, cause and results of late reoperations
    • J.E. Bachet, J.L. Termignon, G. Dreyfus Aortic dissection-prevalence, cause and results of late reoperations J Thorac Cardiovasc Surg 108 1994 199 206
    • (1994) J Thorac Cardiovasc Surg , vol.108 , pp. 199-206
    • Bachet, J.E.1    Termignon, J.L.2    Dreyfus, G.3
  • 5
    • 0035170047 scopus 로고    scopus 로고
    • Surgical strategy for large pseudoaneurysms of the aortic isthmus
    • M. Ricci, E.R. Rosenkranz, T.A. Salerno Surgical strategy for large pseudoaneurysms of the aortic isthmus Eur J Cardiothorac Surg 20 2001 1240 1242
    • (2001) Eur J Cardiothorac Surg , vol.20 , pp. 1240-1242
    • Ricci, M.1    Rosenkranz, E.R.2    Salerno, T.A.3
  • 6
    • 0028194890 scopus 로고
    • Hypothermic circulatory arrest in operations on the thoracic aorta
    • M.A. Ergin, J.D. Galla, S.L. Lansman Hypothermic circulatory arrest in operations on the thoracic aorta J Thorac Cardiovasc Surg 107 1994 788 799
    • (1994) J Thorac Cardiovasc Surg , vol.107 , pp. 788-799
    • Ergin, M.A.1    Galla, J.D.2    Lansman, S.L.3
  • 7
    • 0027751812 scopus 로고
    • Pseudoaneurysms of the aorta after cardiac surgery or chest trauma
    • A. Razzouk, S. Gundry, N. Wang Pseudoaneurysms of the aorta after cardiac surgery or chest trauma Am Surg 59 1993 818 823
    • (1993) Am Surg , vol.59 , pp. 818-823
    • Razzouk, A.1    Gundry, S.2    Wang, N.3
  • 8
    • 0023033299 scopus 로고
    • Eleven-year experience with composite graft replacement of the ascending aorta and aortic valve
    • N.T. Kouchoukos, W.G. Marshall Jr, T.A. Wedige-Stecher Eleven-year experience with composite graft replacement of the ascending aorta and aortic valve J Thorac Cardiovasc Surg 92 1986 691 705
    • (1986) J Thorac Cardiovasc Surg , vol.92 , pp. 691-705
    • Kouchoukos, N.T.1    Marshall Jr., W.G.2    Wedige-Stecher, T.A.3
  • 9
    • 0034017887 scopus 로고    scopus 로고
    • Coil embolization of a false aneurysm with aorto-cutaneous fistula after prosthetic graft replacement of the ascending aorta
    • B. Miguel, L. Camilleri, J. Gabrillargues Coil embolization of a false aneurysm with aorto-cutaneous fistula after prosthetic graft replacement of the ascending aorta Eur J Radiology 34 2000 57 59
    • (2000) Eur J Radiology , vol.34 , pp. 57-59
    • Miguel, B.1    Camilleri, L.2    Gabrillargues, J.3
  • 10
    • 0026517154 scopus 로고
    • Doppler echocardiographic evaluation of pseudoaneurysms complicating composite graft of the ascending aorta
    • J. Barbetseas, E.S. Crawford, H.J. Safi, J.S. Coselli, M.A. Quinones, W.A. Zoghbi Doppler echocardiographic evaluation of pseudoaneurysms complicating composite graft of the ascending aorta Circulation 85 1992 212 222
    • (1992) Circulation , vol.85 , pp. 212-222
    • Barbetseas, J.1    Crawford, E.S.2    Safi, H.J.3    Coselli, J.S.4    Quinones, M.A.5    Zoghbi, W.A.6
  • 11
    • 0022402523 scopus 로고
    • Redo operations for recurrent aneurysmal disease of the ascending aorta and transverse arch
    • E.S. Crawford, J.L. Crawford, H.J. Safi, J.S. Coselli Redo operations for recurrent aneurysmal disease of the ascending aorta and transverse arch Ann Thorac Surg 40 1985 439 455
    • (1985) Ann Thorac Surg , vol.40 , pp. 439-455
    • Crawford, E.S.1    Crawford, J.L.2    Safi, H.J.3    Coselli, J.S.4
  • 12
    • 0031016869 scopus 로고    scopus 로고
    • Percutaneous occlusion of the entry to a leaking false aneurysm after ascending aortic replacement for aortic dissection type a facilitating surgical repair
    • J.P.S. Henriques, A.B. de la Rivere, M. Schepens, J. Ernst Percutaneous occlusion of the entry to a leaking false aneurysm after ascending aortic replacement for aortic dissection type A facilitating surgical repair Eur J Cardiothorac Surg 11 1997 381 383
    • (1997) Eur J Cardiothorac Surg , vol.11 , pp. 381-383
    • Henriques, J.P.S.1    De La Rivere, A.B.2    Schepens, M.3    Ernst, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.