메뉴 건너뛰기




Volumn 26, Issue 4, 2005, Pages 325-327

Can cardiac pacemakers and magnetic resonance imaging systems co-exist?

Author keywords

[No Author keywords available]

Indexed keywords

ARTIFICIAL HEART PACEMAKER; EDITORIAL; HEART VENTRICLE FIBRILLATION; HEATING; HUMAN; IN VITRO STUDY; MORTALITY; NONHUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PHANTOM; PRIORITY JOURNAL; RADIOFREQUENCY RADIATION; SAFETY; TACHYCARDIA; TREATMENT CONTRAINDICATION;

EID: 14144255090     PISSN: 0195668X     EISSN: None     Source Type: Journal    
DOI: 10.1093/eurheartj/ehi084     Document Type: Editorial
Times cited : (29)

References (10)
  • 1
    • 0033500251 scopus 로고    scopus 로고
    • Concerns about sources of electromagnetic interference in patients with pacemakers
    • Sakakibara Y, Mitsui T. Concerns about sources of electromagnetic interference in patients with pacemakers. Jpn Heart J 1999; 40:737-743.
    • (1999) Jpn Heart J , vol.40 , pp. 737-743
    • Sakakibara, Y.1    Mitsui, T.2
  • 2
    • 0029969886 scopus 로고    scopus 로고
    • Safe performance of magnetic resonance imaging on five patients with permanent cardiac pacemakers
    • Gimbel JR, Johnson D, Levine PA, Wilkoff BL. Safe performance of magnetic resonance imaging on five patients with permanent cardiac pacemakers. Pacing Clin Electrophysiol 1996;19:913-919.
    • (1996) Pacing Clin Electrophysiol , vol.19 , pp. 913-919
    • Gimbel, J.R.1    Johnson, D.2    Levine, P.A.3    Wilkoff, B.L.4
  • 3
    • 0024060859 scopus 로고
    • Loss prevention case of the month: Not my responsibility!
    • Avery JE. Loss prevention case of the month: not my responsibility! J Term Med Assoc 1988;81:523.
    • (1988) J Term Med Assoc , vol.81 , pp. 523
    • Avery, J.E.1
  • 5
    • 0035030124 scopus 로고    scopus 로고
    • Interference with cardiac pacemakers by magnetic resonance imaging: Are there irreversible changes at 0.5 tesla?
    • Vahlhaus C, Sommer T, Lewalter T, Schimpf, R, Schumacher B, Jung W et al. Interference with cardiac pacemakers by magnetic resonance imaging: are there irreversible changes at 0.5 tesla? Pacing Clin Electrophysiol 2001;24:489-495.
    • (2001) Pacing Clin Electrophysiol , vol.24 , pp. 489-495
    • Vahlhaus, C.1    Sommer, T.2    Lewalter, T.3    Schimpf, R.4    Schumacher, B.5    Jung, W.6
  • 6
    • 0034077462 scopus 로고    scopus 로고
    • MR imaging and cardiac pacemakers: In vitro evaluation and in vivo studies in 51 patients at 0.5 T
    • Sommer T, Vahlhaus C, Lauck G, Smekal A, Reinke M, Hofer U et al. MR imaging and cardiac pacemakers: in vitro evaluation and in vivo studies in 51 patients at 0.5 T. Radiology 2000;215:869-879.
    • (2000) Radiology , vol.215 , pp. 869-879
    • Sommer, T.1    Vahlhaus, C.2    Lauck, G.3    Smekal, A.4    Reinke, M.5    Hofer, U.6
  • 7
    • 14144250965 scopus 로고    scopus 로고
    • Magnetic resonance imaging of the brain at 1.5 tesla in patients with cardiac pacemakers: Can it be done?
    • Schmiedel A, Hackenbroch M, Reinke M, Yang A, Schimpf R, Xhlild H et al. Magnetic resonance imaging of the brain at 1.5 tesla in patients with cardiac pacemakers: can it be done? Abstract. J Card Magn Reson 2002;4:39-40.
    • (2002) J Card Magn Reson , vol.4 , pp. 39-40
    • Schmiedel, A.1    Hackenbroch, M.2    Reinke, M.3    Yang, A.4    Schimpf, R.5    Xhlild, H.6
  • 8
  • 10
    • 14144252694 scopus 로고    scopus 로고
    • In vivo heating of pacemaker leads during magnetic resonance imaging
    • First published on November 29, doi:10.1093/ eurheartj/ehi009
    • Luechinger R, Zeijlemaker VA, Pedersen EM, Mortensen P, Falk E, Duru F, Candinas R, Boesiger P. In vivo heating of pacemaker leads during magnetic resonance imaging. Eur Heart J 2005; 26:376-383. First published on November 29, 2004, doi:10.1093/ eurheartj/ehi009.
    • (2004) Eur Heart J , vol.26 , pp. 376-383
    • Luechinger, R.1    Zeijlemaker, V.A.2    Pedersen, E.M.3    Mortensen, P.4    Falk, E.5    Duru, F.6    Candinas, R.7    Boesiger, P.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.