메뉴 건너뛰기




Volumn 40, Issue 6, 2005, Pages 727-737

Advanced control of condensing temperature for enhancing the operating efficiency of air-cooled chillers

Author keywords

Air cooled chiller; Condenser fans; Condensing temperature; Efficiency

Indexed keywords

ALGORITHMS; CLIMATE CONTROL; CONDENSATION; CONDENSERS (LIQUEFIERS); ENERGY EFFICIENCY; EVAPORATORS; REFRIGERATION; TEMPERATURE CONTROL;

EID: 14044279794     PISSN: 03601323     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.buildenv.2004.08.017     Document Type: Article
Times cited : (26)

References (20)
  • 1
    • 0141887711 scopus 로고    scopus 로고
    • Energy analysis of commercial buildings in subtropical climates
    • J.C. Lam Energy analysis of commercial buildings in subtropical climates Building and Environment 35 2000 19-26
    • (2000) Building and Environment , vol.35 , pp. 19-26
    • Lam, J.C.1
  • 2
    • 0036630063 scopus 로고    scopus 로고
    • Applying condensing-temperature control in air-cooled reciprocating water chillers for energy efficiency
    • K.T. Chan F.W. Yu Applying condensing-temperature control in air-cooled reciprocating water chillers for energy efficiency Applied Energy 72 2002 565-581
    • (2002) Applied Energy , vol.72 , pp. 565-581
    • Chan, K.T.1    Yu, F.W.2
  • 4
    • 2942733574 scopus 로고    scopus 로고
    • Optimum set point of condensing temperature for air-cooled chillers
    • K.T. Chan F.W. Yu Optimum set point of condensing temperature for air-cooled chillers International Journal of HVAC&R Research 10 2 2004 113-127
    • (2004) International Journal of HVAC&R Research , vol.10 , Issue.2 , pp. 113-127
    • Chan, K.T.1    Yu, F.W.2
  • 6
    • 0037332940 scopus 로고    scopus 로고
    • An analysis of electricity end-use in air-conditioned office buildings in Hong Kong
    • J.C. Lam D.H.W. Li S.O. Cheung An analysis of electricity end-use in air-conditioned office buildings in Hong Kong Building and Environment 38 2003 493-498
    • (2003) Building and Environment , vol.38 , pp. 493-498
    • Lam, J.C.1    Li, D.H.W.2    Cheung, S.O.3
  • 8
    • 0035331797 scopus 로고    scopus 로고
    • Improving the efficiency of chilled water plants
    • G. Avery Improving the efficiency of chilled water plants ASHRAE Journal 43 2001 14-18
    • (2001) ASHRAE Journal , vol.43 , pp. 14-18
    • Avery, G.1
  • 9
    • 0003500096 scopus 로고    scopus 로고
    • Air-conditioning and Refrigeration Institute 3rd ed. Upper Saddle River, NJ: Prentice-Hall
    • Air-conditioning and Refrigeration Institute Refrigeration and air conditioning 3rd ed. 1998 Prentice-Hall Upper Saddle River, NJ
    • (1998) Refrigeration and Air Conditioning
  • 10
    • 0002618691 scopus 로고    scopus 로고
    • Energy saving controls for air-cooled water chillers
    • April
    • Smith M, King G. Energy saving controls for air-cooled water chillers. Building Services Journal April 1998; 47-8.
    • (1998) Building Services Journal , pp. 47-48
    • Smith, M.1    King, G.2
  • 11
    • 0005130683 scopus 로고    scopus 로고
    • Energy efficient chiller control
    • (Technical Note TN 16/2000). Bracknell: Building Services Research and Information Association
    • Roper MA. Energy efficient chiller control (Technical Note TN 16/2000). Bracknell: Building Services Research and Information Association, 2000.
    • (2000)
    • Roper, M.A.1
  • 12
    • 0037374937 scopus 로고    scopus 로고
    • Component matching of a simple vapor compression refrigeration system
    • K.A. Joudi H.N.H. Namik Component matching of a simple vapor compression refrigeration system Energy Conversion & Management 44 2003 975-993
    • (2003) Energy Conversion & Management , vol.44 , pp. 975-993
    • Joudi, K.A.1    Namik, H.N.H.2
  • 15
    • 0034033266 scopus 로고    scopus 로고
    • Mathematical modelling of supermarket refrigeration systems for design, energy prediction and control
    • Y.T. Ge S.A. Tassou Mathematical modelling of supermarket refrigeration systems for design, energy prediction and control Proceedings of the Institution of Mechanical Engineers 214 A 2000 101-114
    • (2000) Proceedings of the Institution of Mechanical Engineers , vol.214 , Issue.A , pp. 101-114
    • Ge, Y.T.1    Tassou, S.A.2
  • 16
    • 0034831397 scopus 로고    scopus 로고
    • Measurement considerations for the determination of central plant efficiency
    • S.J. Treado T. Snouffer Measurement considerations for the determination of central plant efficiency ASHRAE Transactions 107 1 2001 401-406
    • (2001) ASHRAE Transactions , vol.107 , Issue.1 , pp. 401-406
    • Treado, S.J.1    Snouffer, T.2
  • 17
    • 4444376283 scopus 로고    scopus 로고
    • Standard 550/590: Water chilling packages using the vapor compression cycle
    • Air-conditioning and Refrigeration Institute. Arlington, Virginia
    • Air-conditioning and Refrigeration Institute. Standard 550/590: Water chilling packages using the vapor compression cycle. Arlington, Virginia, 1998.
    • (1998)
  • 18
    • 0023398318 scopus 로고
    • Optimization of chilled water systems
    • B.N. Gidwani Optimization of chilled water systems Energy Engineering 84 5 1987 30-50
    • (1987) Energy Engineering , vol.84 , Issue.5 , pp. 30-50
    • Gidwani, B.N.1
  • 19
    • 0026241754 scopus 로고
    • Improving efficiency in existing chillers with optimization technology
    • A. Kaya Improving efficiency in existing chillers with optimization technology ASHRAE Journal 33 1991 30-38
    • (1991) ASHRAE Journal , vol.33 , pp. 30-38
    • Kaya, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.